A metal door for houses is a hinged or pivoted exterior leaf built on a metal frame — aluminium, steel or iron — carrying a panel or glazed infill. In China’s export market the dominant build for residential projects is a 6063-T5 aluminium thermal-break profile with powder-coated or fluorocarbon finish, because it holds a 1.8 mm wall at roughly one third the mass of a steel leaf. This article documents the material comparison, production parameters, technical indicators, certifications, procurement terms, installation method and delivered project data for metal doors sourced from Chinese manufacturers, with USD price tables and configuration comparisons.
FOB price
$95–420/set

U-value
1.4–2.4 W/m²K

Profile wall
1.4 / 1.8 / 2.0 mm

MOQ
20 sets

Lead time
25–35 days

Contents
1. Aluminum vs Steel Door
2. Steel Doors for Home
3. Metal Door Specifications
4. Exterior Doors for Houses
5. Price Table (USD)
6. Production Process
7. Technical Indicators
8. Certifications
9. Procurement Data
10. Installation Method
11. Customer Case
12. Configuration Comparison
13. Related Products

Aluminum vs Steel Door — Weight, Corrosion and Cost Data

The first specification decision on a metal door is the base material. Steel and aluminium dominate residential export orders; cast iron and wrought iron survive mainly in decorative gates and heritage projects. The table below uses measured figures from a standard 900 × 2100 mm single leaf.

Measured Comparison, 900 × 2100 mm Leaf

Indicator Aluminium 6063-T5 Galvanised steel Cast / wrought iron
Leaf weight 18–24 kg 45–60 kg 70–110 kg
Profile wall 1.4–2.0 mm 0.8–1.5 mm 3–6 mm solid
Hinge cycles rated 200,000 200,000 100,000
Salt spray (ASTM B117) 1,000 h, no base corrosion 480–720 h before red rust at cut edges 240 h, needs annual repaint
Whole-door U-value 1.4–2.2 W/m²K 2.4–3.5 W/m²K 3.5–5.0 W/m²K
FOB China, per set $95–420 $70–260 $380–900
Container load, 40HQ 260–320 sets 180–220 sets 90–130 sets

Why the Weight Gap Changes Hardware

A 55 kg steel leaf needs three heavy-duty butt hinges or a continuous geared hinge plus a reinforced frame anchor every 400 mm. An aluminium leaf at 22 kg runs on two hinges with anchors at 600 mm. On a 60-unit housing project that difference removes roughly 2 tonnes of dead load from the openings and cuts on-site labour by an estimated 0.4 man-hours per opening, because one installer can hang an aluminium leaf without a lifting aid.

Corrosion Behaviour in Coastal Zones

Steel fails at cut edges, drill holes and weld seams, not on the flat panel — the zinc layer is consumed locally and red rust spreads under the coating. Aluminium forms a self-limiting oxide and, with an AA-class pretreatment plus a 60–80 μm powder coat, reaches 1,000 h neutral salt spray with no base metal attack. For sites within 2 km of salt water, specify 6063-T5 with a chromate-free pretreatment and a fluorocarbon (PVDF 70%) topcoat; measured chalking after 3 years Florida exposure is under 1 ΔE on PVDF versus 3–5 ΔE on standard polyester powder.

Steel Doors for Home — Where Aluminum Replaces Steel

A steel door still wins on two counts: Impact resistance at a given gauge, and unit price on a bare spec. The switch to aluminium happens when one of the following three conditions is present on the project.

Condition 1 — Coastal or High-Humidity Site

Measured maintenance logs from a 2023 apartment block in Qinzhou, Guangxi (800 m from the shoreline): galvanised steel entrance doors required edge repainting at month 18 and full replacement of 14 of 96 leaves by month 42. The aluminium leaves installed in the same building in the second phase showed coating chalk but no substrate loss at month 48. Over a 10-year window the aluminium option cost $41 per opening less in maintenance, against a $55 higher initial unit price.

Condition 2 — Wide or Tall Leaves

Above 1,100 mm leaf width or 2,400 mm leaf height, a steel leaf needs an internal steel skeleton and a heavier frame to control twist. Aluminium extrusions hold flatness within 1.5 mm over 2.4 m at 2.0 mm wall thickness without added reinforcement. Pivot entry doors at 1,200 × 2,700 mm are routinely built in aluminium at 38 kg; the same size in steel exceeds 90 kg and requires a floor-mounted pivot rated above 150 kg.

Condition 3 — Thermal Code Compliance

Where the local code sets a whole-door U-value at or below 2.0 W/m²K — parts of the EU under EN 14351-1, and IECC climate zones 5 to 8 in the US — a non-thermal-break steel leaf at 2.4–3.5 W/m²K will not pass on its own. Adding a polyurethane core and thermal break to steel closes the gap to about 1.9 W/m²K but moves the unit price to $210–300, above a comparable aluminium build at $180–260. For projects targeting NFRC labelling, the aluminium route reaches U 1.4 W/m²K with a 24 mm polyamide break and a Low-E double-glazed insert.

Metal Door Specifications — Profile, Infill and Hardware

A metal door specification has three layers: the extruded profile system, the infill, and the hardware set. Each layer has measurable parameters that should appear on the order sheet, not in a marketing paragraph.

Profile System and Thermal Break

Infill Options and Acoustic Result

Infill Build Rw (dB) U-value W/m²K Added cost
Single aluminium panel 1.5 mm sheet, PU backing 28 2.2 base
Sandwich panel 0.8 mm skin + 40 mm PU 32 1.6 +$28/set
Double glazed 5+12A+5 Low-E 35 1.8 +$45/set
Laminated glazed 6+0.76PVB+6 / 12A / 6 40 1.5 +$72/set

Hardware Set

Exterior Doors for Houses — Sizing, Threshold and Sealing

Exterior doors for houses carry a different tolerance set from commercial entrances: the opening is usually a masonry or timber rough opening with ±10 mm variation, and the water management has to work without a curtain-wall drainage plane behind it.

Standard and Custom Sizes

Threshold and Sill Detail

Three sill configurations are used: a standard 20 mm thermal-break threshold for covered entrances, a 45 mm rebated sill with an external drainage channel for exposed elevations, and a flush recessed sill for barrier-free access. The rebated sill with a 6 mm weep slot every 300 mm discharges water that penetrates the outer seal; in a 15-minute spray test at 300 Pa the flush sill retained 40 mL of water at the inner face versus 3 mL for the rebated type.

Sealing and Drainage

Two continuous seals are minimum: an EPDM bulb seal on the frame stop and a silicone-blade or brush seal at the leaf bottom. Compression should be 2–3 mm at closed position — below 1 mm the air leakage rate rises from 1.5 to 4.5 m³/h·m² at 100 Pa. The frame’s drainage path must exit above the sill flashing; a blocked weep hole is the single most common cause of water ingress claims on residential aluminium doors.

Price Table (USD) — Metal Doors for Houses

Prices below are FOB Shenzhen or Foshan, quoted for a 900 × 2100 mm single leaf, 1.8 mm wall, powder-coated, hardware included, at an order quantity of 100 sets. They exclude sea freight, import duty and local installation.

FOB Price by Configuration

Configuration Break / wall Finish FOB / set Typical use
Entry-level panel door No break / 1.4 mm Polyester powder 60 μm $95–135 Interior, warm climates
Standard thermal-break PA66 20 mm / 1.8 mm Polyester powder 70 μm $165–235 Residential main entry
Glazed insert door PA66 24 mm / 1.8 mm Powder 70 μm $210–290 Villa front entrance
PVDF coastal build PA66 24 mm / 2.0 mm PVDF 70% 40 μm $255–340 Seaside projects
Oversize pivot door PA66 30 mm / 2.0 mm PVDF or anodised 15 μm $380–520 1,200 × 2,700 mm feature entry

What Moves the Price

Budget note: for a 100-set residential order, plan on $165–235 per set for the door, $38–55 per set for sea freight to a US west coast port at current rates, and 3.4% import duty under HTS 7610.10 for aluminium doors. Landed cost before local installation lands at $210–300 per set.

Production Process — From Billet to Packed Door

Extrusion and Alloy Control

6063 aluminium billet (Si 0.2–0.6%, Mg 0.45–0.9%) is heated to 460–500 °C and extruded at 8–15 m/min through a die, then quenched by air or water and artificially aged at 200 °C for 2 hours to reach T5 temper. Wall thickness is checked by ultrasonic gauge every 30 minutes; the tolerance band is ±0.1 mm on a nominal 1.8 mm.

Surface Treatment Parameters

Assembly and Glazing

Profiles are cut on a double-head saw to ±0.3 mm, corner-crimped with a 2-component epoxy injected into the corner cleat, then sealed. Thermal-break strips are rolled into the knurled channels under 8–12 kN pressure; a pull-off test on every 200th profile must exceed 200 N/cm. Glazing is set on EPDM gaskets with a 6 mm bite, and the IGU is held by a structural silicone bead with 24-hour curing before packing.

Technical Indicators — Structural, Air, Water and Acoustic

Performance Test Results

Indicator Test standard Standard build Hurricane build
Wind load resistance EN 12211 / ASTM E330 ±1,800 Pa (Class C4) ±4,800 Pa, DP 60 psf
Air permeability EN 1026 / ASTM E283 Class 3 (≤1.5 m³/h·m²) Class 4 (≤0.5 m³/h·m²)
Watertightness EN 1027 / ASTM E331 450 Pa (Class 6A) 700 Pa (Class 9A)
Thermal transmittance EN 10077 / NFRC 100 1.8–2.2 W/m²K 1.4–1.6 W/m²K
Acoustic insulation EN ISO 717-1 Rw 32–35 dB Rw 40–43 dB
Operating force EN 12046-2 ≤60 N at leaf edge ≤80 N (heavier glazing)

Interpreting the Numbers on a Quote

Ask for the test report number, the tested size, and the configuration tested. A wind rating measured on a 900 × 2100 mm leaf does not transfer to a 1,200 × 2,700 mm pivot leaf — the moment on the hinge rises by a factor of roughly 2.1. Where a supplier quotes only “Class 4” or “DP50” without a report, request the laboratory name and the test date; NFRC and AAMA listings are publicly searchable.

Certifications — What Each Market Requires

Market-Specific Approvals

Documents to Request Before Ordering

Request the mill certificate for the 6063 billet (heat number and chemical analysis), the coating thickness report per batch, the thermal-break pull-off test log, and the IGU certificate to EN 1279. These four documents take a supplier under a day to produce and filter out trading companies that cannot trace material back to the extrusion press.

Procurement Data — MOQ, Lead Time, Payment and Packing

MOQ and Lead Time

Payment Terms

Standard is 30% T/T deposit with 70% against a copy of the bill of lading. Irrevocable L/C at sight is accepted for orders above $50,000 and adds 0.6–1.1% in bank charges. For repeat buyers, 30/70 with a 2% discount for full prepayment is common; open account terms start only after 3 completed orders.

Packing Specification

Layer Material Note
1 PE foam sleeve, 3 mm Full leaf wrap
2 Corner protection, 5 mm EPE 8 corners per set
3 5-ply export carton 275 gsm kraft, 1.62 m³ per 10 sets
4 Fumigated plywood crate (optional) +$14/set, ISPM 15 stamped, for LCL

Installation Method — Sequence, Waterproofing and Commissioning

Installation Sequence

Waterproofing Detail

Two-stage sealing: an inner air seal of low-expansion foam or pre-compressed tape, and an outer weather seal of neutral-cure silicone on a closed-cell backer rod, tooled to a 6 × 6 mm bead. Bond-break tape goes on the frame face before the silicone so the bead is free to move. Silicone should be applied at 5–40 °C and above 40% RH; a bead applied on a damp substrate fails inside 12 months.

Commissioning Checks

Customer Case — 62-Unit Villa Project, Queensland

A developer building 62 detached houses 3.4 km from the Queensland coast compared a galvanised steel entrance package against a thermal-break aluminium package across the full build.

Project Data

Item Aluminium package Steel package quoted
Doors supplied 62 entry + 62 rear 62 entry + 62 rear
Unit price FOB $212 (PVDF, 2.0 mm) $158 (galv + PU core)
Container count 1 × 40HQ (124 sets) 2 × 40HQ (124 sets)
Freight to Brisbane $3,100 $6,200
Installed hours / opening 1.6 2.3
Compliance result AS 2047 N4/C4/W6, U 1.9 AS 2047 N4/C4/W6, U 2.6 — failed energy check
Landed + installed / set $341 $357

The steel package was $54 cheaper per unit FOB but $16 more expensive per opening once freight, one extra container, and 0.7 additional labour hours were counted — and it did not pass the project’s energy compliance check at U 2.6 against a 2.2 target. The aluminium package was specified.

Configuration Comparison — Which Build for Which Site

Site condition Recommended build Key parameter Budget / set
Inland, temperate Thermal-break, powder PA66 20 mm, 1.8 mm wall $165–235
Coastal, under 2 km PVDF, 2.0 mm wall 1,000 h salt spray, AA20 anodise alternative $255–340
Hurricane zone Impact laminated, reinforced DP 60 psf, Miami-Dade NOA, TAS 201/203 $420–620
Cold climate, U ≤ 1.6 PA66 30 mm, triple insert U 1.4 W/m²K, warm-edge spacer $290–380
Roadside, Rw ≥ 38 Laminated glazed insert 6+0.76PVB+6 / 12A / 6, Rw 40 dB $255–330

Related documentation on the same product family: