Home > Blog > Aluminum Window Supplier in China: GB/T 8478 Specs and FOB Pricing
Aluminum Window Supplier in China: GB/T 8478 Specs and FOB Pricing
Thermal-break aluminum windows (窗户) on a residential facade: casement, sliding and fixed units with double glazing.
窗户 is the Chinese word for window, and it is the search term Chinese-speaking buyers, developers and contractors use when they want aluminum window systems rather than door systems. This article covers the window-only scope: frame alloy and wall thickness, glazing sized to design wind pressure, hardware selected by sash mass, GB/T and EN performance grading, FOB price bands, cutting yield from a 6.5 m extrusion bar and a jumbo glass sheet, and the landed arithmetic for two delivered projects.
窗户 Terminology Bridge: Chinese Spec Terms and English Equivalents
Most specification errors between a Chinese factory and an overseas buyer are not material errors, they are vocabulary errors. A purchase order written in Chinese uses a fixed set of terms that map to specific English items; the table below is the working translation used on export orders.
Chinese term
Literal
English equivalent on a PO
Where it decides cost
窗户
window
window (generic)
Scope: window only, excludes doors
窗框
window frame
outer frame / outer profile
Profile linear metres, mullion count
窗扇
window leaf
sash / vent
Hardware set, operating gear
固定窗
fixed window
fixed light / picture window
Cheapest per m², no hardware
平开窗
side-hung window
casement window
Hinges, espagnolette, restrictor
推拉窗
push-pull window
sliding window
Rollers, track, brush seals
上悬窗
top-hung window
awning window / top-hung vent
Friction stay, chain winder
内开内倒
inward-open, inward-tilt
tilt-and-turn window
Full Euro-groove gear set
双悬窗
double-hung window
double hung / single hung
Balances, sash travel limit
百叶窗
louver window
louver / jalousie window
Glass clips, operator, blade count
中空玻璃
hollow glass
insulated glazing unit (IGU)
Cavity, gas fill, spacer type
钢化玻璃
tempered glass
tempered / toughened glass
EN 12150, thickness step
夹胶玻璃
sandwich glass
laminated glass (PVB/SGP)
EN 14449, impact rating
隔热条
heat-break strip
thermal break strip (PA66 GF25)
14.6–34 mm width drives Uf
壁厚
wall thickness
profile wall thickness
1.4 / 1.8 / 2.0 mm; GB/T 8478 floor
型材
profile
extrusion / profile
Alloy 6063-T5 / T6, kg per metre
粉末喷涂
powder spray
polyester powder coating
60–80 μm DFT
氰碳喷涂
fluorocarbon spray
PVDF coating (2-coat / 3-coat)
25–35 μm, 20-yr colour
阳极氧化
anodic oxidation
anodising (AA15 / AA20 / AA25)
15–25 μm oxide
气密性
air tightness
air permeability
EN 12207 class / GB q1
水密性
water tightness
water tightness
EN 12208 class / GB ΔP
抗风压
wind resistance
wind load resistance
EN 12210 class / GB P3
窗地比
window-to-floor ratio
window-to-floor area ratio
Code minimum 1/7 in Chinese residential
采光井
daylight well
window well / light well
Below-grade egress and drainage
纱窗
gauze window
insect screen
Retractable / fixed / pleated
The single most expensive translation error is 壁厚. When a drawing says 1.4 mm and the buyer assumed 1.8 mm, the frame passes a quote comparison and fails the load check. Write the number on the PO, not the adjective.
Where the Terminology Decides Cost
Three of the terms above move money directly. 中空玻璃 (IGU) bundles cavity, gas and spacer into one line, so an order that simply says double glazing leaves three variables open and each one is worth $8–40/m². 隔热条 (thermal break) is quoted by strip width, not by its presence, and the width is what sets Uf. 壁厚 (wall thickness) is quoted in millimetres and decides whether the unit clears its wind class at all.
Writing the Order in Two Languages
The practical method is a bilingual schedule: Chinese terms on the left for the production floor, English equivalents on the right for the buyer, and a numeric column for every variable — thickness in mm, strip width in mm, cavity in mm, cycles as an integer, pressure in Pa. Where a term has no single English equivalent, as with 内开内倒 (tilt-and-turn), write the standard reference instead: a tilt-before-turn sequence with a defined locking position is unambiguous in any language.
Aluminum Window Frame: Alloy, Wall Thickness and Thermal Break Width
A window frame is an extrusion system. Four variables drive its cost and its measured performance: alloy and temper, wall thickness, thermal break width, and the number of sealing lines. Everything else is a finish or an accessory.
Alloy and Temper: 6063-T5 vs 6063-T6
Export window profiles are extruded from 6063 (Al–Mg–Si). T5 is air- or water-quenched at the press exit and artificially aged; T6 is solution treated near 520 °C, water quenched, then aged. The mechanical difference matters for tall sashes and for corner crimp strength:
Property
6063-T5 (EN 755-2 / GB 5237.1)
6063-T6
What it changes on a window
Tensile strength Rm
≥ 160 MPa
≥ 205 MPa
Mullion span before reinforcement
Yield strength Rp0.2
≥ 110 MPa
≥ 160 MPa
Deflection under design wind
Elongation A50
≥ 8%
≥ 8%
Corner crimping without cracking
Typical use
Standard sash and frame
Tall mullions, coastal wind classes
Price adder $2–4/kg
Hardness (Webster)
≥ 8 HW
≥ 11.5 HW
Scratch resistance on site
T6 costs more per tonne and is not always available from every press, so it is normally specified only for the mullion sections of a large fixed light rather than for the whole window.
Wall Thickness: 1.4 / 1.8 / 2.0 mm and What GB/T 8478-2020 Requires
Wall thickness is measured on the main load-bearing walls of the profile, not on the screw ports or decorative ribs. GB/T 8478-2020 sets the floor for aluminium windows and doors sold in China: outer windows are not to be built below 1.8 mm on the main profile, outer doors below 2.0 mm. Export orders for markets with lower wind classes still frequently run 1.4 mm for cost reasons, which is a legitimate choice if the wind class and the span allow it — but it must be an explicit line item.
Wall thickness
Profile mass
Typical application
Wind class ceiling
FOB band
1.4 mm
0.95–1.15 kg/m
Small sliding and casement, low-rise
EN 12210 class 2–3 (800–1200 Pa)
$65–150/m²
1.8 mm
1.20–1.45 kg/m
Standard export casement and sliding
EN 12210 class 4–5 (1600–2000 Pa)
$95–230/m²
2.0 mm
1.35–1.65 kg/m
External doors, tall vents, HVHZ
EN 12210 class 5 and above, Exxx
$130–300/m²
2.2–3.0 mm
1.7–2.4 kg/m
Curtain-wall mullions, hurricane zones
Miami-Dade NOA ranges
Project quoted
A 1200 × 1500 mm casement consumes about 10.6 linear metres of profile. Moving that window from 1.4 mm to 1.8 mm adds roughly 3.3 kg of aluminium per unit, which at a finished profile price of $4.4–4.8/kg is $15–16 per window, or $8–9 per m² of window area. That is the real cost of the step, and it is worth paying when the design pressure exceeds about 1.5 kPa.
Thermal Break: Strip Width, Material and the Uf It Produces
A thermal break is a polyamide strip (PA66 with 25% glass fibre) mechanically locked into two aluminium half-shells by knurling and rolling. Its width, not the alloy, sets the frame U-value.
Strip width
Strip form
Frame Uf (EN ISO 10077-2)
Whole-window Uw with 5-12A-5 Low-E
Adder vs non-break
None
—
5.5–6.8 W/m²K
3.4–4.0 W/m²K
baseline
14.6 mm
I-strip
3.0–3.6 W/m²K
2.4–2.8 W/m²K
+$16–24/m²
18.6 mm
I-strip
2.6–3.1 W/m²K
2.1–2.5 W/m²K
+$20–30/m²
24 mm
C / multi-chamber
2.2–2.6 W/m²K
1.8–2.2 W/m²K
+$26–38/m²
34 mm
Multi-chamber + foam
1.7–2.1 W/m²K
1.4–1.8 W/m²K
+$34–52/m²
Two material checks belong on every order: the strip must be PA66 GF25, not PVC (PVC creeps under clamp load and loses the composite action), and the composite section should be tested for shear and tension across the break. A break that delaminates is invisible until the sash racks.
Uf is measured on a standard 1900 × 1500 mm test specimen per EN ISO 10077-2, not on your window. The frame share of a real window is typically 25–35% of the area, so a Uf improvement of 1.0 W/m²K moves the whole-window Uw by roughly 0.25–0.35 W/m²K — useful, but never as large as the brochure number suggests.
Sealing Lines and Drainage Paths in the Frame
Air and water performance is decided by the seal layout, not by the glass. A casement built with three sealing lines and a pressure-equalised drainage chamber typically lands two EN classes higher than the same section built with two.
Line 1 (outer): EPDM or silicone gasket at the frame-to-sash rebate, continuous, welded or vulcanised corners.
Line 2 (middle): the pressure-equalisation chamber, drained to the outside through slotted weep holes with a baffle or a one-way flap.
Line 3 (inner): the interior gasket that keeps the drained cavity out of the room air.
Drainage: slot area should total at least 2 × the sash perimeter rule-of-thumb of 5 mm² per 100 mm; blocked weep slots are the most common water-tightness failure on site.
Glazing rebate: drained and vented to the outside, never sealed on all four sides, otherwise the IGU edge sits in water.
Glass Windows for Houses: IGU Build-Ups and Thickness by Design Wind Load
The glass specification for a house window is decided by three numbers: the design wind pressure at the site, the pane size, and the thermal target. Once those three are fixed, there is only one correct thickness, and it can be calculated rather than guessed.
From Wind Speed to Design Pressure
Velocity pressure is q = 0.613 V² with V in m/s and q in Pa, for the 3-second gust used in most window load standards. External and internal pressure coefficients then modify q by shape and by whether the building is sealed; for an initial specification the raw table below is the practical starting point.
Gust wind speed
Velocity pressure q
Typical site
Consequence for the window
25 m/s
0.38 kPa
Sheltered inland, low-rise
5 mm glass adequate to 1.8 m span
30 m/s
0.55 kPa
Inland suburban
Standard class, 5 mm
35 m/s
0.75 kPa
Open suburban, 3–6 storey
5 mm to 1.5 m, 6 mm above
40 m/s
0.98 kPa
Coastal, 6–12 storey
6 mm, check mullion deflection
45 m/s
1.24 kPa
Exposed coastal
6 mm, reinforced mullions above 2.1 m
50 m/s
1.53 kPa
Cyclone / typhoon belt
6–8 mm, laminated inner pane
60 m/s
2.21 kPa
HVHZ design event
8–10 mm laminated, impact tested
70 m/s
3.00 kPa
Miami-Dade HVHZ
Impact glazing, NOA-listed build
Pane Size and Design Pressure Decide the Thickness
For a rectangular pane simply supported on four edges, the maximum bending stress is σ = β · q · b² / t², where b is the short side in mm, q the design pressure in N/mm², t the glass thickness in mm, and β a shape factor that rises from 0.287 for a square to 0.750 for a long strip. Taking 50 MPa as the design bending stress for fully tempered glass (characteristic strength near 120 MPa with a safety factor above 2) gives the following required thicknesses. Figures in brackets are the raw calculated value before rounding up to a stock thickness.
Pane (w × h, mm)
1.0 kPa
1.5 kPa
2.0 kPa
2.5 kPa
3.0 kPa
4.0 kPa
600 × 900
4 mm (1.9)
4 mm (2.3)
4 mm (2.7)
4 mm (3.0)
4 mm (3.2)
4 mm (3.7)
900 × 1200
4 mm (2.6)
4 mm (3.2)
4 mm (3.7)
5 mm (4.2)
5 mm (4.6)
6 mm (5.3)
1140 × 1440
4 mm (3.2)
4 mm (4.0)
5 mm (4.6)
6 mm (5.1)
6 mm (5.6)
8 mm (6.5)
1200 × 1800
4 mm (3.7)
5 mm (4.6)
6 mm (5.3)
6 mm (5.9)
8 mm (6.5)
8 mm (7.5)
1500 × 2100
5 mm (4.5)
6 mm (5.5)
8 mm (6.4)
8 mm (7.1)
8 mm (7.8)
10 mm (9.0)
1800 × 2400
6 mm (5.3)
8 mm (6.4)
8 mm (7.4)
10 mm (8.3)
10 mm (9.1)
12 mm (10.5)
The step is not gradual. Widening a vent from 1140 mm to 1200 mm and raising it from 1440 mm to 1800 mm moves the requirement at 2.0 kPa from 5 mm to 6 mm, and the glass mass of the sash rises by 20%, which in turn pushes the hinge and stay class up. One dimension change cascades through glass, hardware and operator force.
Asymmetric IGUs and Load Sharing
In an insulated glazing unit the two panes share the wind load in proportion to their bending stiffness, which scales with the cube of thickness. This is why an asymmetric build-up is often the cheapest way to clear a load case:
IGU build
Load on outer pane
Load on inner pane
Why it is used
5 + 12A + 5
50%
50%
Standard residential, both panes equally stressed
6 + 12A + 5
63%
37%
Wind on the outside pane; saves 1 mm inside
8 + 12A + 6
70%
30%
Large lights, laminated inner pane for safety
6 + 12A + 6
50%
50%
Balanced, used above 2.0 kPa or above 1.8 m span
Thermal Build-Ups, Gas Fill and Spacer
Once the thickness is fixed by load, the coating and the cavity decide the thermal and acoustic numbers. Measured centre-of-glass values used in export quoting:
Build
Coating / fill
Ug (W/m²K)
SHGC
Rw (dB)
Adder vs clear 5-12A-5
5 + 12A + 5 clear
none / air
2.6–2.8
0.72–0.78
30–31
baseline
5 + 12A + 5 Low-E
soft-coat Low-E / air
1.6–1.8
0.55–0.65
31–32
+$10–16/m²
5 + 12Ar + 5 Low-E
Low-E / argon 90%
1.1–1.3
0.55–0.62
32–33
+$18–28/m²
6 + 16Ar + 6 Low-E
Low-E / argon, 16 mm
1.0–1.1
0.52–0.58
33–34
+$26–40/m²
5 + 9A + 5 + 9A + 5
triple, Low-E / argon
0.6–0.7
0.45–0.52
34–35
+$52–86/m²
6 + 1.52 PVB + 6 in IGU
laminated inner pane
1.2–1.4
0.50–0.58
36–39
+$22–34/m²
Warm-edge spacers (stainless or composite instead of aluminium) raise the temperature at the glass edge by 3–6 K at 0 °C outside / 20 °C inside, which is the cheapest defence against perimeter condensation. Argon retention should be specified at 90% fill and verified by the EN 1279 gas concentration test or by a spark test on the sealed unit.
Double Hung Windows: Sash Travel, Balances and Size Ceilings
A double hung window has two vertically sliding sashes in one frame; a single hung moves only the lower sash. Both are common in North American residential work and both are specified around the balance hardware rather than around the profile.
Sash Mass Sets the Balance Class
Balance capacity must be matched to the sash it carries. Mass is computed from the glass area and build-up plus the sash profile: 25 kg/m² for 5-12A-5, 30 kg/m² for 6-12A-6, plus roughly 1.3 kg per linear metre of sash profile.
Sash size (mm)
Glass area
IGU mass
Sash profile
Total sash mass
Balance spec
600 × 900
0.36 m²
9.0 kg
3.9 kg
12.9 kg
2 × 7 kg spiral
800 × 1200
0.75 m²
18.8 kg
5.2 kg
24.0 kg
2 × 12 kg block & tackle
1000 × 1400
1.16 m²
29.0 kg
6.2 kg
35.2 kg
2 × 18 kg constant force
1200 × 1600
1.62 m²
40.5 kg
7.3 kg
47.8 kg
2 × 24 kg, heavy-duty class
1200 × 1800
1.85 m²
46.3 kg
7.8 kg
54.1 kg
Beyond standard hung; use casement
Specify balances to AAMA 902 with a declared cycle life and a capacity within ±10% of sash mass. An over-specified balance makes the sash creep upward; an under-specified one makes it drop. Both are reported as a ‘hardware failure’ on site when the hardware is actually correct and only the capacity is wrong.
Size Ceilings and Why Hung Windows Stop at About 1.8 m
Span: a hung sash is guided at the jambs only, so the top rail deflects as a beam between the balance attachment points. Above roughly 1600 mm width the top rail needs reinforcement.
Travel: each sash travels about half the frame height. A 2400 mm tall frame means 1200 mm of travel per sash, which demands a deeper head section and longer balance travel.
Operator height: the lock and lift handle must stay within reach; above 2000 mm sill height the upper sash lock becomes unusable without a pole operator.
Air sealing: sliding contact seals have more leakage than compression seals. A double hung typically lands one EN 12207 class below an equivalent casement.
Cleaning: tilt-in sashes require pivot bars rated to the full sash mass, not to the glass mass.
For facades where the hung aesthetic is required above these ceilings, the standard answer is a hung-look fixed upper light with a genuine operating lower sash. Details of the trade-off are covered in single hung vs double hung selection.
Cycle Testing and What to Write on the PO
Window durability is classified in EN 12400 (classes 1 / 2 / 3 = 5,000 / 10,000 / 20,000 opening cycles) and tested by the repeated-movement method in EN 1191. Export residential specs normally call for class 2. Write four items on the order:
Durability class (EN 12400 class 2 = 10,000 cycles) and the test report number.
Balance capacity in kg per sash, with the ±10% tolerance and AAMA 902 reference.
Operating force limit, measured per EN 13115 — specify a maximum newton value, not a ‘smooth operation’ description.
Sash travel limit and any restrictor, with the restrictor’s declared pull-out rating and test evidence.
Basement Windows: Egress Dimensions, Wells and Drainage Capacity
A below-grade window does three jobs at once: it admits light, it must let a person out in a fire, and it must not become a water entry point. Those three requirements pull in different directions, and the conflict is resolved by dimensions rather than by products.
Egress Dimensions Written Into the PO
Where a basement window serves a sleeping room or a habitable space, the North American model code (IRC R310) sets minimum net clear opening dimensions. These are the numbers a fabricator needs, because they are measured on the clear opening with the sash fully open, not on the frame size:
Requirement
IRC value
Metric
Note for fabrication
Net clear opening area
5.7 ft²
0.530 m²
Measured with sash at full open
Grade-floor exception
5.0 ft²
0.465 m²
Applies at or below grade level
Minimum net clear height
24 in
610 mm
Often the controlling dimension
Minimum net clear width
20 in
508 mm
Drives the vent width, not the frame width
Maximum sill height
44 in
1,118 mm
Above finished floor
Window well area
9 ft²
0.84 m²
Horizontal area of the well
Minimum well dimension
36 in
914 mm
Projection and width
Ladder / steps required
depth > 44 in
> 1,118 mm
Permanent, non-removable
A casement vent is the usual way to clear the 508 mm width rule: a 600 mm wide frame with a casement vent gives roughly 520 mm of clear width, while a sliding unit of the same frame only gives about 290 mm. This is a geometry argument, not a hardware argument.
Window Wells: Storage Volume and Drain Sizing
A well is a small basin attached to the foundation. Its drainage is not sized by the well area alone, because the well also intercepts wall runoff from the excavation face. Worked example for a 914 × 914 mm well, 900 mm deep:
Direct rainfall: 0.84 m² at 100 mm/h = 84 L/h = 1.4 L/min.
Wall runoff: a 6 m² excavated face draining into the well at the same intensity = 600 L/h = 10 L/min.
Total inflow: about 11.4 L/min during a 100 mm/h event.
Drain capacity: a 75 mm PVC pipe at 1% slope carries roughly 170 L/min at full bore (Manning, n = 0.011) — fifteen times the inflow.
Conclusion: capacity is never the problem. The failure mode is a blocked or non-existent outlet.
If the drain blocks completely, the well fills from its 0.75 m³ void: 750 L at 600 L/h gives about 75 minutes before water reaches the sill. That is the number to design against, and it is why the details below matter more than the pipe diameter.
Gravel bed 100–150 mm, separated from the soil by filter fabric so fines do not migrate upward.
Outlet connected to the footing drain or to daylight, never to a sealed sump that can back up.
Well cover in polycarbonate with a declared snow and foot-traffic load, vented so the well does not become a condensation trap against the glass.
Sill of the window at least 150 mm above the finished gravel level and 200 mm above the surrounding grade where the grade slopes toward the house.
Positive seal at the frame-to-foundation joint using a flexible membrane lapped over a backer rod, not a bead of sealant on the surface.
Below-Grade Waterproofing Sequence
Prepare the opening; chamfer or fill spalls so the frame seats on sound concrete.
Apply a liquid or sheet membrane to the concrete reveal, lapping 150 mm onto the exterior face.
Set the frame on packers, never on the membrane alone; the membrane is not structural.
Fix with stainless anchors at 300–400 mm centres, first anchor within 150 mm of each corner.
Insert a backer rod into the frame-to-concrete joint and tool a neutral-cure silicone over it; the joint must be able to move.
Install the well, gravel and cover, then flood-test the well with a hose for 10 minutes before backfilling.
Backfill in lifts, keeping the filter fabric continuous to the surface.
Sizing to the Stock: Profile Bar and Jumbo Sheet Cutting Yield
Two supply-chain facts set a floor on window price that has nothing to do with quality: aluminium comes off the press in 6.5 m bars, and float glass comes off the line in jumbo sheets. Both are bought by length or by sheet, and both are sold to the buyer by square metre of finished window. The difference between the two is cutting waste, and cutting waste is decided by the dimensions on the drawing.
Profile: 6.5 m Bars and the Batch Effect
A 1200 × 1500 mm casement consumes eight profile pieces: two 1500 mm jambs, two 1200 mm head and sill sections, two 1440 mm sash stiles and two 1140 mm sash rails — 10,584 mm of profile including a 3 mm saw kerf per cut. Nesting those pieces into 6,500 mm bars gives the following, using an optimised cut list rather than simple first-fit placement:
Batch size
Bars consumed
Bars per unit
Length yield
Effective profile per m²
Adder vs best case
1 unit
2
2.00
81.4%
$43.2/m²
+$5.4/m²
2 units
4
2.00
81.4%
$43.2/m²
+$5.4/m²
4 units
7
1.75
93.0%
$37.8/m²
+$0.0/m²
8 units
14
1.75
93.0%
$37.8/m²
+$0.0/m²
16 units
27
1.69
96.5%
$36.5/m²
−$1.3/m²
The model behind the money column: 10.6 m of profile at about 1.30 kg per metre and a finished powder-coated profile price of $4.6/kg. At 81.4% yield the factory buys 16.9 kg to deliver 13.8 kg; at 93% it buys 14.8 kg. That 2.1 kg difference is $9.70 per window, or $5.4 per m² on a 1.8 m² unit.
Simple first-fit cutting software reaches only 81–90% even on large batches, which is why two factories quoting the identical section can differ by $4–6/m² on a small order. Ask whether the cut list is optimised, and ask how many identical units the price assumes.
Glass: Jumbo Sheet Yield Tiles, It Does Not Scale Linearly
The obvious assumption — that bigger panes waste more — is wrong. What matters is how the pane tiles onto the sheet. On a 2440 × 3660 mm jumbo (8.93 m²) with a 3 mm cutting kerf:
Pane size (mm)
Panes per sheet
Usable area
Yield
Effective float cost per m²
500 × 600
28
8.40 m²
94.1%
$3.0
800 × 1000
9
7.20 m²
80.6%
$3.5
1000 × 1200
6
7.20 m²
80.6%
$3.5
1140 × 1440
4
6.57 m²
73.5%
$3.8
1200 × 1500
4
7.20 m²
80.6%
$3.5
1500 × 1800
2
5.40 m²
60.5%
$4.6
1800 × 2100
2
7.56 m²
84.7%
$3.3
The 1800 × 2100 mm pane yields 84.7% while the 1140 × 1440 mm pane yields only 73.5%, because two of the large panes tile the sheet almost exactly and four of the medium ones leave an unusable strip down one edge. The 1500 × 1800 mm pane is the worst case in this set at 60.5%.
Converting yield into money, with 5 mm float at $2.8/m² of sheet, tempering at $4.5/m² of pane and IGU assembly at $9/m²:
Pane size
Yield
Float cost
Tempering (×2 panes)
IGU assembly
IGU total per m²
500 × 600
94.1%
$3.0
$9.0
$9.0
$21.0
1140 × 1440
73.5%
$3.8
$9.0
$9.0
$21.8
1500 × 1800
60.5%
$4.6
$9.0
$9.0
$22.6
1800 × 2100
84.7%
$3.3
$9.0
$9.0
$21.3
Spread across the glass cost alone the yield effect is $1.6/m². It becomes material once the thickness step is added: at 2.0 kPa the 1140 × 1440 pane needs 5 mm and the 1500 × 2100 pane needs 8 mm, which is 60% more glass mass, a heavier sash, a higher hardware class and a thicker IGU overall. Yield is the small lever; the thickness step is the large one.
Five Rules That Cut Waste Without Changing the Design
Repeat sizes. Every additional identical unit moves the cut list toward the batch columns above.
Keep vent widths on a 100 mm module and under 1200 mm where the elevation allows.
Check the pane against the sheet before confirming: 1500 × 1800 is the worst common size on a 2440 × 3660 sheet.
Order glass by cut size, not by window size; the two differ by the rebate depth and by the glazing clearance.
State the jumbo size in the RFQ. A factory running 2140 × 3210 sheet will price large panes very differently from one running 2440 × 3660.
Window-to-Floor Ratio, Solar Gain and Heating Load per Window
窗地比 (window-to-floor area ratio) is the Chinese planning metric that fixes how much window a room must have before energy is even considered. Most residential codes work from a minimum of 1/7, and energy codes then cap the window-to-wall ratio by orientation. The resulting area is small, so the per-window energy arithmetic is small too — which is exactly why the upgrade decision should be made with numbers rather than with adjectives.
Sizing From the 1/7 Rule
A 3.6 × 4.2 m bedroom is 15.1 m² of floor. At 1/7 the window must provide at least 2.16 m², which is a single 1200 × 1800 mm unit. Two such rooms share one 2.4 m rough opening and one mullion.
Room floor area
Minimum glass at 1/7
Practical window
Frame area
Glazing area
9.0 m²
1.29 m²
1 × 900 × 1500
1.35 m²
1.01 m²
15.1 m²
2.16 m²
1 × 1200 × 1800
2.16 m²
1.62 m²
22.0 m²
3.14 m²
2 × 900 × 1800
3.24 m²
2.43 m²
32.0 m²
4.57 m²
2 × 1200 × 2000
4.80 m²
3.60 m²
Annual Heat Loss by U-Value
Using degree-hours is the honest way to compare: Q = A · U · (HDD × 24) where HDD is the annual heating degree-days in K·d. For a cold-winter site with 2,600 K·d that is 62,400 K·h, so annual loss per m² of window = U × 62.4 kWh. Applied to the 2.16 m² window:
Window build
Uw (W/m²K)
Loss for 2.16 m²
Cost at $0.14/kWh
Delta vs baseline
Non-break aluminium, 5-12A-5 clear
3.7
499 kWh/yr
$69.9
baseline
Non-break, 5-12A-5 Low-E
3.0
404 kWh/yr
$56.6
−$13.3/yr
14.6 mm break, Low-E
2.6
350 kWh/yr
$49.0
−$20.9/yr
24 mm break, Low-E argon
2.0
270 kWh/yr
$37.8
−$32.1/yr
34 mm break, 6-16Ar-6 Low-E
1.6
216 kWh/yr
$30.2
−$39.7/yr
The 24 mm break plus Low-E argon costs about $46/m² more than the non-break build, which is $99 on a 2.16 m² window, and saves $32.1 per year at $0.14/kWh. Simple payback is 3.1 years on electricity. On gas at $0.08/kWh equivalent the saving is $18.4/yr and payback is 5.4 years. Both are inside a normal ownership period, which is the only argument needed.
Solar Gain Is Not Symmetrically Good
The same window that loses heat also collects it. South-facing (northern hemisphere) winter gain at 300 W/m² average daytime irradiance and SHGC 0.55 over 2.16 m² is 356 W; across 4 useful hours per day for 150 days that is 214 kWh/yr, which offsets 79% of the 270 kWh loss of the 24 mm build. On a north or west facade the same glass becomes a cooling penalty: 500 W/m² summer peak × SHGC 0.55 × 2.16 m² = 594 W, which at a COP of 3 and 900 equivalent full-load hours is about 178 kWh of electricity per year, or $25.
The practical rule is orientation-dependent glass, not a single house-wide build: higher SHGC (0.55–0.65) on the solar-gain facade, lower SHGC (0.30–0.40) with a reflective or tinted coating on the west and on unshaded east elevations. It costs the same per m² to order two coatings as one, provided the two are declared on the schedule before production.
FOB Price Table (USD) by Window Type and Configuration
FOB Foshan or FOB Shenzhen, in USD per square metre of window area, for orders at or above 100 m² with a single colour and a single hardware brand. Prices below 100 m² carry a small-order adder of $6–14/m² because set-up, cutting and inspection costs are fixed per order rather than per square metre.
What the FOB price normally includes: profile, glass, hardware, gaskets, fabrication, standard export packing and factory-side loading. What it normally does not: third-party testing, destination duty and taxes, inland delivery at destination, installation, and any engineering stamp. Confirm each of the five — the last one, an Engineer’s seal, can cost more than the glass upgrade it was meant to protect.
Reading a Quotation: Where in the Band a Window Lands
Every row above is a range. Four variables move a window from the bottom of its band to the top: batch size (see the cutting-yield section), the number of distinct sizes on the schedule, the hardware brand, and the finish. A 300 m² order of four repeated sizes in one colour with a house-brand gear set sits near the lower bound; a 40 m² order of eleven different sizes in two colours with European hardware sits near the upper one. The spread between those two positions is larger than the spread between most competing factories.
Production Process: From Billet to Packed Crate
Eleven stages separate an aluminium billet from a crated window. Each has a parameter that can be written into a specification, and each has a failure mode that is invisible in the finished product.
Extrusion, Ageing and Mechanical Properties
Billet: 6063 casting, homogenised. Melt composition logged per heat; Mg and Si ratio kept near the Mg2Si balance so the age-hardening response is predictable.
Extrusion: billet 460–520 °C, press 1,600–2,500 t, exit speed 8–25 m/min depending on section complexity, controlled by exit temperature rather than by ram speed.
Quench: air or water at the press exit. T5 takes this quench plus artificial ageing; the alternative T6 route re-solutions near 520 °C before ageing.
Stretch: 0.5–1.5% permanent stretch to remove bow and twist before cutting.
Ageing: T5 artificial ageing near 180–205 °C for 2–4 h; T6 near 175 °C for 6–8 h. Hardness is verified by Webster or by Brinell on sample lengths.
Surface Treatment Parameters
Treatment
Thickness
Key parameters
Test reference
Service life
Anodising AA15 / AA20 / AA25
15 / 20 / 25 μm
Sealed, colour consistency by bath control
ISO 7599, ISO 2135
20–30 yr
Polyester powder
60–80 μm DFT
Chrome-free pre-treatment, metal temp 180–200 °C for 10–15 min
Qualicoat, GSB, AAMA 2603/2604
15–25 yr
PVDF 2-coat
≥ 25 μm
Bake 230–250 °C peak metal temp
AAMA 2605
20–30 yr
PVDF 3-coat
≥ 35 μm
Primer / base / clear
AAMA 2605
25–35 yr
Wood-grain transfer
Film over powder base
Vacuum transfer, then clear or powder topcoat
ISO 9227 salt spray 1,000 h
10–15 yr
Colour consistency is the most common quality dispute. It is controlled by measuring ΔE on production panels against a master; a ΔE of 1.0 is visible side by side on a large elevation, so specify the tolerance rather than approving a single 100 × 100 mm chip.
Thermal Break Insertion, Fabrication and Glazing
Knurling: the polyamide strip channel is knurled so the teeth bite into the aluminium before rolling; the composite section is then pull-tested.
Cutting: double-head saw, length tolerance ±0.2 mm, mitre ±0.1°. Corner clearance is set here, and a corner gap above 0.3 mm will show as a weep path.
Crimping: corners crimped or pinned; corner shear strength is tested on sample corners per production batch.
Drainage: slots milled, then checked for burrs that trap water.
IGU assembly: spacer filled with desiccant, butyl primary seal, secondary seal in polysulfide, silicone or hot-melt; argon filled to 90% and verified.
Glazing: setting blocks at quarter points, glazing gasket or structural silicone, edge clearance 5–6 mm per side.
Quality checkpoints worth writing into the inspection clause: dimensional check on 10% of units, glass certificate traceability to the tempering furnace batch, 100% visual and operating check, and a water-spray test on one unit per 200 or per order, whichever is smaller.
Technical Indicators: GB/T 8478-2020 and the EN Performance Classes
Chinese domestic projects are specified against GB standards; export projects against EN, AAMA, NFRC or AS. A single window can satisfy both, but the numbers are reported differently and the two sets are not interchangeable.
GB/T 8478-2020: What It Sets for Aluminium Windows
GB/T 8478 is the product standard for aluminium windows and doors in China. The clauses that appear in export correspondence are the wall-thickness floor, the performance grading referenced to GB/T 7106, and the hardware and safety requirements:
Clause area
Requirement
How it is verified
Typical export result
Main profile wall thickness
Outer windows not below 1.8 mm; outer doors not below 2.0 mm
Micrometer on cut section
1.4 mm on request, 1.8 mm default export
Air permeability
Graded by q1 (m³/(m·h)) and q2 per GB/T 7106
Pressure chamber, stepped pressure
q1 ≤ 1.0 on three-seal casement
Water tightness
Graded by ΔP (Pa), stepped or cyclic spray
Spray rack, 15 min per step
350–500 Pa on casement, 250–350 Pa on sliding
Wind load resistance
Graded by P3, with deflection limit L/… per grade
Pressure chamber, cyclic and safety load
P3 2.5–4.0 kPa typical export
Thermal transmittance
K value graded per GB/T 8484
Guarded hot box or calculation
K 1.8–2.8 W/m²K with thermal break
Airborne sound
Rw graded per GB/T 8485
Reverberant chamber
Rw 32–39 dB by build
Hardware
Cycle and load requirements on operating gear
Durability rig
10,000 cycles standard
EN 12207 / 12208 / 12210 and What a Class Number Means
Export test reports to EN 14351-1 quote three classifications. Read them in this order, because a window with a high wind class and a low water class is a common and expensive combination:
Property
Standard
Class scale
What to specify for a mid-rise residential unit
Air permeability
EN 12207
Class 0–4 (class 4 tested at 600 Pa)
Class 4, with the q value stated, not just the class
Water tightness
EN 12208
1A–9A (0 to 600 Pa), then Exxx
8A (450 Pa) minimum; 9A or E750 on exposed elevations
Wind resistance
EN 12210
Class 1–5 (400 to 2000 Pa), then Exxx
Class 4 or 5 to suit the site; deflection class B or C
Deflection
EN 12210
A ≤ L/150, B ≤ L/200, C ≤ L/300
Class C for mullions over 2.4 m span
Durability
EN 12400
1 / 2 / 3 = 5,000 / 10,000 / 20,000 cycles
Class 2 for residential, class 3 for commercial
Operating force
EN 13115
Measured force, N
State a maximum newton value on the PO
Thermal transmittance
EN ISO 10077-1 / 12567-1
Uw in W/m²K
Uw ≤ 1.8 for temperate, ≤ 1.2 for cold
A class number without a pressure value is not a specification. Class 4 air permeability is tested at 600 Pa, but the q value at that pressure is what separates a well-sealed window from one that only just passed. Always ask for the measured value alongside the class.
Reading a Test Report Without Being Misled by It
Check the specimen size. A 1230 × 1480 mm test window is the standard EN size; results do not transfer to a 2400 mm unit without recalculation.
Check whether the reported Uw is measured or calculated. Calculated values per EN ISO 10077-1 are legitimate but can differ from a hot-box measurement by 0.1–0.2 W/m²K.
Check the hardware brand on the report. The wind class was achieved with a specific gear set; substituting a cheaper one voids the evidence.
Check the date and the scope. A report issued for a sliding system does not cover the casement in the same series.
Check the laboratory accreditation. An ISO/IEC 17025 accredited lab report is what a building inspector will accept.
Certifications and Test Reports Required by Market
Certification is market-specific and, in most cases, product-specific. The list below is what a window shipment is normally asked to produce, grouped by destination.
Market
Mandatory or expected
Standard / scheme
What the document proves
Typical cost and time
European Union
CE marking for windows and doors
EN 14351-1, AVCP system 3, DoP
Air, water, wind, and (where declared) thermal and acoustic performance
$1,200–3,400, 4–8 weeks
United States
NFRC label plus AAMA/WDMA/CSA performance class
AAMA/WDMA/CSA 101/I.S.2/A440, NFRC 100/200
U-factor, SHGC, VT and the performance class (R / LC / C / HC / AW)
$1,800–5,000, 6–12 weeks
Florida HVHZ
Miami-Dade NOA or Florida Product Approval
TAS 201, 202, 203; AAMA 506
Impact resistance and cyclic pressure after impact
$8,000–20,000, 4–9 months
Australia / NZ
Compliance to the National Construction Code
AS 2047, AS 1288, AS 4055 wind classes
Wind class N1–N6 / C1–C4, glass selection to AS 1288
$1,400–3,600, 4–8 weeks
Middle East
Often project-specific third-party review
ASTM E283 / E331 / E330, NFRC
Air, water, and structural performance at project pressures
$900–2,800, 3–6 weeks
China domestic
Type test to the GB system
GB/T 8478-2020, GB/T 7106-2019
Graded air, water, wind, K value, Rw
$600–2,000, 2–5 weeks
Factory systems
ISO 9001 / 14001 / 45001
—
Process control, not product performance
Annual audit, factory held
Component-Level Documents That Must Travel With the Shipment
Component-level certificates that should accompany the shipment: EN 12150 for tempered glass, EN 14449 for laminated glass, EN 1279 for the sealed unit, EN 12365 or equivalent for gaskets, Qualicoat or GSB or AAMA 2604/2605 for the coating, and the IGU gas-fill declaration.
Glass: furnace batch certificate with the tempering standard and the thickness; the certificate number should be traceable to the individual unit on the packing list.
Sealed unit: EN 1279 parts 2 and 3 evidence for gas fill and for moisture penetration resistance, plus the spacer type.
Coating: the licence number of the powder or PVDF system, and the film thickness records from the production day.
Thermal break: the strip manufacturer and grade; PA66 GF25 must be named, not described as nylon.
Who Signs for the Performance
Certification proves the tested assembly, not the installed building. The split of responsibility is consistent across most markets and belongs in the contract:
Market
Who signs the structural adequacy
What the manufacturer supplies
EU / UK
Local structural engineer or the building control body
CE DoP, AEV test report, Uw calculation
United States
Architect or engineer of record; a state-licensed PE stamp for many jurisdictions
NFRC label, AAMA class report, shop drawings for approval
Florida HVHZ
Product approval holder plus the local building department
NOA or FPA number, approved size and configuration tables
Australia / NZ
Building certifier, with AS 4055 or AS 1170 wind classification by the engineer
AS 2047 report, AS 1288 glass selection, NCC evidence
Middle East
Project consultant or third-party reviewer
ASTM test report at project pressures, material submittals
A CE marking on a window does not remove the local engineering responsibility. In the EU the installer and the designer still have to show the window suits that building’s wind zone; in the US an HVHZ approval is a product approval that must be matched to the approved sizes and configurations in the NOA, and any deviation increases the scope rather than the product.
Procurement Data: MOQ, Lead Time, Payment, Packing and Container Maths
The commercial terms on a window order are standard enough to be tabulated, and the container arithmetic is worth doing before the quotation rather than after it.
Item
Standard export position
Notes
MOQ
30 m² or 10 units, whichever is larger
Below MOQ, a set-up charge of $180–420 applies
Sample window
$180–400 plus freight, credited on the first production order
Samples are built to the real spec, not to a display spec
Drawing approval
5–7 days
The only compressible item in the schedule; everything else is fixed
Production
25–35 days from approved drawings
Add 5–10 days for PVDF, triple glazing or custom colour
Payment
30% deposit, 70% before shipment; LC at sight accepted
LC adds 3–5 days of document handling
Incoterms
FOB Foshan / FOB Shenzhen, EXW or CIF on request
CIF requires the destination port at quotation time
Packing
PE foam, corner protectors, then plywood crate
Crate 1.2 × 2.4 × 1.6 m typical; fumigation certificate if required
Warranty
10 years on profile and coating, 1–2 years on hardware
Hardware warranty follows the hardware brand, not the fabricator
Container Loading: Weight Limits Before Volume
A finished aluminium window with double glazing weighs about 20–25 kg/m² and occupies roughly 0.055 m³ per m² once crated. A 40HQ gives about 68 m³ of usable volume and roughly 26,000 kg of payload:
Constraint
Calculation
Result
Volume limit
68 m³ ÷ 0.055 m³/m²
1,236 m²
Weight limit
26,000 kg ÷ 23 kg/m²
1,130 m²
Governing
Weight
About 1,100–1,150 m² per 40HQ
Freight cost
$2,600–3,400 per 40HQ
$2.4–3.0 per m²
20GP alternative
About 480 m²
$3.8–4.6 per m²
Glass is roughly 80% of the mass of a crated window and a little over half its volume, so knock-down packing does not help much on a window: the frames are light and the glass is the problem. The levers that do move the number are glazing on site with locally sourced glass, or reducing pane thickness where the load case allows it.
The largest single landed-cost variable is not freight, it is classification. Aluminium windows and doors are normally entered under HS 7610, but anti-dumping and derivative-product duties on Chinese aluminium in the EU and the US have been extended to a widening list of downstream goods, and the position changes. Confirm the tariff heading, the current duty and any AD or Section 232 exposure before comparing a Chinese FOB price against a local quote — the duty line can be larger than the entire configuration upgrade budget.
RFQ Checklist: Eight Items That Remove a Round of Questions
Window schedule: type, size (width × height), quantity, and whether width is given first.
Design wind pressure in kPa, with the standard it was derived from.
Glass build, coating, gas fill, and whether the inner pane is laminated.
Thermal break width, or the Uw target — give one, not both.
Colour and coating system (powder / PVDF / anodising) with the standard.
Hardware brand and finish, plus any restrictor or child-safety requirement.
Certification required, and the market it is for.
Destination port, so freight and packing can be quoted at the same time.
Installation: Flashing Sequence, Anchoring and Commissioning
Most water complaints on aluminium windows are installation complaints. The sequence below is the new-construction sequence; retrofit differs only in the first two steps.
Opening Tolerance and Anchoring
Rough opening: window size plus 10–15 mm per side for shimming and anchor clearance; check the opening is square within 5 mm on the diagonal before the unit arrives.
Anchor spacing: 300–400 mm centres with the first anchor within 150 mm of each corner; stainless steel straps or screws into masonry with a declared pull-out value.
Packers: at each anchor and under each mullion, never under the sash only; remove or leave them so they do not bridge the drainage path.
Level and plumb: ±1.5 mm per metre. A racked frame shows up as a sash that drifts when released, which is then misdiagnosed as a hardware problem.
Expansion: aluminium moves about 23 × 10−6 per K; a 2.4 m frame moves 2.2 mm across a 40 K swing, so the perimeter joint must be a movement joint, not a rigid fill.
Flashing Sequence
Sill pan first: pre-formed pan or flexible membrane with end dams turned up at least 50 mm, lapped onto the sheathing or the masonry reveal.
Set the window into the pan, on packers, and check that the weep slots are clear of the pan upstand.
Jamb flashing lapped over the sill pan, not under it; the lap direction must shed downward and outward.
Head flashing with end dams and a drip edge, lapped over the jamb flashing and under the weather-resistive barrier above.
Air seal on the interior: backer rod plus neutral-cure silicone, or a compatible sealant tape; this is the air line, the flashings are the water line.
Flood test: before the interior finishes go on, spray the head and jambs for 10 minutes and check the sill pan drains to the outside.
Commissioning and the Six Failures That Follow
Commission each unit: operate five times, check the sash stays where released, check the lock engages without lifting the sash, confirm the drain slots are open, and record the glass certificate numbers against the window schedule.
Failure
Site symptom
Root cause
Fix
Water at the sill
Staining below the sill
No end dams on the sill pan, or pan lapped the wrong way
Re-install the pan; sealant alone will not hold
Sash drifts open
Vent swings when unlocked
Frame racked or out of plumb by more than 1.5 mm/m
Re-shim the frame at the anchors
Condensation at the glass edge
Mould line on the perimeter
Cold aluminium spacer, no warm edge, or blocked rebate drainage
Warm-edge spacer; clear the rebate
Handle stiff after two months
High operating force
Balance capacity wrong, or hinge undersized for sash mass
Re-specify to measured sash mass
Whistling at the head
Noise at wind speeds above 12 m/s
Air seal interrupted at the head flashing lap
Continuous interior air line
Coating chalking
Dull, powdery surface in year 5–7
Polyester specified for a high-UV coastal site
PVDF or anodising, and ΔE control
Delivered Project Data: 486 Windows and an Egress Retrofit
Two records from delivered orders, with the arithmetic shown so the numbers can be checked rather than accepted.
Case A: 62-Unit Apartment Block, Cebu, Philippines
486 windows totalling 812 m², average 1.67 m² per unit. Mix: 62% sliding, 24% casement, 14% fixed. Design wind 1.8 kPa from the local typhoon map, which pushes panes above 1500 mm to 6 mm. Non-thermal-break sections with 5-9A-5 clear glazing, since the cooling-dominated climate does not pay back a thermal break.
The two items that moved this project were the glass step and the packing. Sizing every sliding vent at 1200 × 1500 mm kept the pane at 5 mm and kept the jumbo yield at 80.6%; the original elevation had 1500 × 1800 mm lights at 60.5% yield, which added about $4.6/m² in float cost alone before the 6 mm step.
Case B: Basement Egress Retrofit, 24 Units, Toronto
A rental conversion requiring 24 basement windows to meet the egress rule. Casement vents at 900 × 1100 mm giving 520 mm clear width and 1,020 mm clear height, 6-12Ar-6 Low-E with a 20 mm thermal break, plus new wells and excavation done locally.
Line item
Basis
Amount
FOB window value
41 m² at $186/m²
$7,626
Freight (LCL, crated)
1 crate, 41 m²
$680
Duty
6.5%
$540
Installation
$260 per unit × 24
$6,240
Wells, excavation and disposal
$420 per unit × 24, local contractor
$10,080
Total
—
$25,166 ($1,048 per opening)
Local competitive quote
Supply and install, wells included
$44,000 ($1,833 per opening)
Saving
—
−43%, $18,834
The import share of Case B is only 31% of the total. On retrofit work the site costs dominate, so the value of an imported window is decided by whether it arrives complete, protected and correctly labelled — a missing screen or a scratched frame costs more in return freight than the $5/m² saved on the unit price.
Configuration and Material Comparison
Two tables: which window type suits which opening, and which frame material suits which programme.
Window Type by Performance and Cost
Type
Uw achievable
Air class ceiling
Max practical size
FOB band
Best use
Fixed / picture
1.2–2.2
Class 4
3.0 m span with a mullion
$65–195/m²
Views, stair glazing, where no ventilation is needed
Casement
1.4–2.6
Class 4
900 × 2100 vent
$95–265/m²
Best air sealing; bedrooms, egress windows
Sliding
2.2–3.4
Class 3
1200 × 2400 panel
$80–230/m²
Where the vent must not project; balconies
Awning
1.4–2.6
Class 4
1200 × 1200 vent
$105–275/m²
Ventilation in rain; combined with fixed below
Double hung
1.8–3.0
Class 3
1200 × 1600 sash
$120–300/m²
North American residential, facade rhythm
Tilt-and-turn
1.2–2.0
Class 4
1000 × 2200 vent
$140–395/m²
European markets, cleaning from inside
Louver
3.0–4.5
Class 1–2
900 × 1500 bank
$90–190/m²
Ventilation priority; not a weather seal
Frame Material: Eight Criteria
Criterion
Aluminium non-break
Aluminium 24 mm break
uPVC 3-chamber
Wood-aluminium clad
Steel thermal break
Frame Uf (W/m²K)
5.5–6.8
2.2–2.6
1.8–2.2
1.2–1.5
2.0–2.8
Max sash height
2.4–2.8 m
2.4–2.8 m
1.5–1.8 m
2.0–2.4 m
2.4–3.0 m
Service life
40–50 yr
40–50 yr
25–35 yr
30–60 yr
40–60 yr
Recycled content
60–75% typical
60–75%
0–20%
Low
60–90%
Fire behaviour
Non-combustible
Non-combustible
Combustible, softens
Combustible core
Non-combustible
Maintenance cycle
10–15 yr
10–15 yr
5–10 yr seals
3–7 yr coating
15–25 yr
Colour stability
15–30 yr by coating
15–30 yr
Fades and chalks
Depends on finish
20–30 yr
FOB band
$65–150/m²
$145–265/m²
$90–180/m²
$260–480/m²
$220–420/m²
Aluminium wins on span, life and fire behaviour; uPVC wins on raw frame U-value at a given price; wood-aluminium wins on U-value and on interior appearance at roughly double the cost. The deciding question is usually the sash height: above about 1.8 m uPVC needs steel reinforcement, and above 2.4 m the comparison stops being close.
How to read these tables without fooling yourself: the U-values are frame or whole-window values on a standard specimen, not on your elevation; the price bands assume one colour, one hardware brand and 100 m² or more; and the material comparison assumes the same glazing throughout. Change the glass and the ranking between the last three columns moves more than the ranking between the first two.
Related Products and Further Reading
Detailed specifications for the individual systems referenced above, grouped by window type and by glazing and accessories.
ROGENILAN builds aluminium window systems in Foshan, Guangdong, for export to residential and commercial projects. Send the eight-item RFQ checklist above and a quotation with a full configuration table comes back within 48 hours.