Blog

Home   >   Folding Doors   >   Porte Accordon Export in China: Portes Pliantes en Aluminium, Accordion Doors Folding Geometry, FOB Pricing

Porte Accordon Export in China: Portes Pliantes en Aluminium, Accordion Doors Folding Geometry, FOB Pricing

Porte accordon aluminium folding door with thermally broken anthracite frames installed on a residential house terrace in China - five-panel bi-fold system with flush threshold
Porte accordon with thermally broken aluminium leaves stacked to one side, flush threshold detail, residential terrace.
A porte accordon is a folding door set: a chain of hinged leaves carried along a head track, stacked against one jamb when open. In the Chinese export build the leaves are 6063-T6 thermally broken aluminium carrying double or triple Low-E glazing, with the whole set weighing 200-460 kg depending on leaf count and glass build-up. This article documents the geometry, the structural demand on the lintel above the opening, hanger wheel contact stress, thermal transmittance by leaf count, threshold and drainage arithmetic, certification scope, FOB pricing by configuration, container loading, landed cost into the EU, installation sequence and two delivered projects, in USD and SI units.
FOB price
$148-252/m²

Uw, 34 mm break
1.36-1.68 W/m²K

Profile wall
1.8 / 2.0 / 2.2 mm

MOQ
30 m² / 6 sets

Lead time
30-45 days

Contents
1. Portes pliantes, porte accordeon, galandage
2. Accordion doors folding geometry
3. The lintel is the product
4. Porte pliante en aluminium hardware
5. Uw and the leaf-count penalty
6. Threshold, drainage, PMR 20 mm
7. Glazing, safety, acoustics
8. Profile, alloy, coating
9. CE, DoP, AEV, RC classes
10. Production flow and inspection
11. FOB pricing by configuration
12. MOQ, lead time, packing
13. Landed cost and anti-dumping
14. Installation and commissioning
15. Failure modes
16. Two delivered projects
17. Porte accordon vs coulissante
18. RFQ, glossary, standards

1. Portes Pliantes, Porte Accordeon and Galandage: What the Order Actually Is

Three French product names are used for wide glazed openings and they are not interchangeable. Getting the name wrong on a purchase order changes what is shipped, because the hardware, the threshold and the structural demand above the opening are different in each case.

Terminology: what each name refers to

French term English equivalent Leaves Weight carried by Typical threshold
Porte accordon / porte accordeon Folding / accordion door 2-7 Head track (top-hung) or sill rail (bottom-rolling) 0-45 mm
Portes pliantes Folding doors (plural) 2-7 Head track or sill rail 0-45 mm
Porte pliante en aluminium Aluminium folding door 2-7 Head track or sill rail 0-45 mm
Porte a galandage Sliding door with wall pocket 1-2 Bottom rollers 0-5 mm
Baie vitree coulissante Sliding patio door 2-3 Bottom rollers 20-45 mm
Porte-fenetre Glazed French door / casement door 1-2 Hinges 15-25 mm
Porte de service (vantail principal) Traffic leaf 1 Hinges Same as set

The last row is the one that is most often missed. A folding set can include one leaf that opens like a normal hinged door, so that a winter errand across the terrace does not require folding the whole set. Specifying it costs USD 45-95 per set and it removes most of the cycle wear from the folding hardware; without it every trip cycles the full chain.

Where each type is specified

For the sliding alternative, the porte coulissante article covers rollers, drainage and large-opening splitting in detail; the comparison in section 17 sets out which of the two the project actually needs.

Reading a French specification: four dimension bases

A French cahier des clauses techniques particulieres (CCTP) uses four different dimension bases for the same opening. Measuring the masonry opening and cutting to the finished size is a 40-60 mm irreversible error, and it is the single most common reason a folding set does not fit on site.

Dimension base Meaning What it is used for
Trou nu de maçonnerie Structural masonry reveal Site measure; what the builder leaves
Tableau Reveal of the finished opening Setting the frame width
Cote de passage Clear passage width when open Accessibility and furniture clearance
Cote d’encombrement Overall occupied footprint when stacked Checking the opening is not blocked by the stack
Dimensions finies Manufactured frame size What the factory cuts to
Write all four on the order. The cote de passage is the one that decides accessibility compliance, and for a folding set it is not the structural width: the stacked leaves stay inside the opening. Section 2 quantifies how much they take.

2. Accordion Doors Folding Geometry: Leaf Count, Leaf Width, Clear Opening

Leaf count is the one decision that drives everything else in a folding set: leaf width, leaf mass, hardware duty, frame fraction, U-value, price and the number of people needed to carry the leaves on site. Fewer leaves means a wider clear opening and a lower U-value, but each leaf is heavier and each lock point carries more wind load.

Leaf count against clear opening, frame fraction and U-value

Leaves Leaf glass width Leaf mass Set mass Stack width Clear opening Frame fraction Uw (34 mm + Low-E)
2 2.29 m 164 kg 329 kg 0.09 m 95.7% 14.6% 1.36
3 1.49 m 109 kg 328 kg 0.17 m 94.0% 16.7% 1.43
4 1.09 m 82 kg 328 kg 0.26 m 92.2% 18.9% 1.49
5 0.85 m 65 kg 327 kg 0.34 m 90.4% 21.1% 1.55
6 0.69 m 54 kg 327 kg 0.42 m 88.6% 23.3% 1.62
7 0.57 m 47 kg 326 kg 0.51 m 86.9% 25.5% 1.68

The pattern is monotonic and it is a genuine trade-off. Going from 2 leaves to 7 on a 4.8 m opening drops the clear opening from 95.7% to 86.9% and raises Uw from 1.36 to 1.68 W/m²K, because every added leaf brings two more meeting stiles. In exchange the leaf mass falls from 164 kg to 47 kg, which is the difference between a glass trolley and two people with suction cups.

The leaf width band that hardware is designed for

Folding door hardware is engineered for leaf widths of roughly 0.55-1.10 m. Outside that band two things happen at once: the hanger load per wheel rises, and the leaf becomes too heavy to handle without equipment. The table below is the same 4.8 m opening with double glazing, classified by the handling method the mass demands.

Leaves Leaf glass width Leaf mass Handling on site
2 2.29 m 164 kg glass trolley / lifting frame
3 1.49 m 109 kg 4 persons + suction cups
4 1.09 m 82 kg 4 persons + suction cups
5 0.85 m 65 kg 2 persons + suction cups
6 0.69 m 54 kg 2 persons + suction cups
7 0.57 m 47 kg 2 persons + suction cups
Two leaves on a 4.8 m opening is a valid drawing and a bad product decision: a 164 kg leaf needs a glass trolley, exceeds the wheel contact limit for a standard 28 mm steel wheel (section 4), and puts 2.2 kN on each lock point at 1.2 kPa wind. Four to six leaves is the working band for this width.

Recommended leaf count by opening width

Opening width (m) Leaves Leaf glass width (m) Leaf mass, Low-E (kg) Why
2.4 2 1.09 82 Two leaves still inside the handling band
3.0 3 0.89 69 Widest leaf that two people can carry
3.6 3-4 1.09 / 0.79 82 / 60 4 leaves preferred if the set is cycled daily
4.2 4 0.94 71 Balanced; stack takes 0.26 m
4.8 5-6 0.85 / 0.69 65 / 54 Standard export configuration
6.0 6-7 0.87 / 0.79 73 / 66 Above 6 m, split into two sets or add a corner post

Above roughly 6.0 m the set should be split in two, or built with an open corner post so the two halves meet without a jamb. A single 7-leaf set at 6.0 m puts 0.51 m of stack on one side and every wind load through one lock stile, which is why the wind table in section 4 has a per-point column that falls as leaf count rises.

Stacking side, traffic leaf and open corners

3. The Lintel Is the Product: Top-Hung Against Bottom-Rolling

A folding set is a hung system. Unlike a sliding door, where the weight goes into the sill and then into the floor, a top-hung folding set delivers its entire dead load into the lintel above the opening. The door manufacturer supplies a head profile; the building supplies the beam. The head profile is not the beam, and this is where folding door projects fail.

Deflection limit is L/500, not L/200

A window or a curtain wall is checked at L/200, or L/300 where the standard requires it. A folding head track has a stricter limit because the criterion is not appearance or glass contact: it is whether the hanger wheels stay engaged and whether the leaves still pass each other without binding. In practice the track is checked at L/500. For a 4.8 m span that is 9.6 mm of allowable deflection, against 24.0 mm at L/200.

Lintel sections: what passes and what does not

Lintel section E (MPa) I (mm⁴) Mid-span deflection Ratio L/500 check
Door head profile 60x60x2.5 (6063-T6) 70000 3.17e+05 207.6 mm L/23 FAIL
Steel RHS 100x50x3 210000 1.12e+06 19.6 mm L/245 FAIL
Steel RHS 150x100x5 210000 7.54e+06 2.9 mm L/1648 PASS
Steel RHS 200x100x6 210000 1.79e+07 1.2 mm L/3919 PASS
Timber lintel 100×200 (C24) 11000 6.67e+07 6.3 mm L/763 PASS
Reinforced concrete lintel 200×250 30000 2.6e+08 0.6 mm L/8128 PASS

The load case is a 4.8 m opening with six Low-E leaves, 326.6 kg hung from the head, a uniform load of 667.5 N/m. Two results in that table decide most projects:

A lintel that was sized only for the masonry above it is a lintel that has never seen this load case. A 4.8 m folding set adds 326.6 kg hanging below the beam, on an eccentric line. The check has to be done by the project engineer against the actual lintel, and it is the first question to ask before quoting.

Required lintel inertia by opening and leaf count

Opening width Leaves Hung mass Required I, steel (mm⁴) Required I, timber (mm⁴)
3.0 m 3 204 kg 5.6e+05 1.1e+07
3.0 m 4 204 kg 5.6e+05 1.1e+07
3.0 m 5 203 kg 5.6e+05 1.1e+07
3.0 m 6 203 kg 5.5e+05 1.1e+07
3.6 m 3 246 kg 9.7e+05 1.8e+07
3.6 m 4 245 kg 9.7e+05 1.8e+07
3.6 m 5 244 kg 9.6e+05 1.8e+07
3.6 m 6 244 kg 9.6e+05 1.8e+07
3.6 m 7 243 kg 9.6e+05 1.8e+07
4.2 m 3 287 kg 1.5e+06 2.9e+07
4.2 m 4 286 kg 1.5e+06 2.9e+07
4.2 m 5 286 kg 1.5e+06 2.9e+07
4.2 m 6 285 kg 1.5e+06 2.9e+07
4.2 m 7 285 kg 1.5e+06 2.9e+07
4.8 m 3 328 kg 2.3e+06 4.4e+07
4.8 m 4 328 kg 2.3e+06 4.4e+07
4.8 m 5 327 kg 2.3e+06 4.4e+07
4.8 m 6 327 kg 2.3e+06 4.4e+07
4.8 m 7 326 kg 2.3e+06 4.4e+07
6.0 m 3 411 kg 4.5e+06 8.6e+07
6.0 m 4 410 kg 4.5e+06 8.6e+07
6.0 m 5 410 kg 4.5e+06 8.6e+07
6.0 m 6 409 kg 4.5e+06 8.6e+07
6.0 m 7 409 kg 4.5e+06 8.5e+07

Required inertia scales with the fourth power of the span, so a 6.0 m set needs roughly 2.4 times the steel of a 4.8 m set even though it is only 25% wider. This is the same rule that governs splitting a large opening: adding an intermediate support is far cheaper than buying the beam.

Head track fixings and the load path

Opening width Leaves Hung mass Fixings at 400 mm Load per fixing (x1.3 dynamic)
3.6 m 4 245 kg 10 313 N
3.6 m 5 244 kg 10 312 N
3.6 m 6 244 kg 10 311 N
3.6 m 7 243 kg 10 310 N
4.8 m 4 328 kg 12 348 N
4.8 m 5 327 kg 12 348 N
4.8 m 6 327 kg 12 347 N
4.8 m 7 326 kg 12 346 N
6.0 m 4 410 kg 16 327 N
6.0 m 5 410 kg 16 327 N
6.0 m 6 409 kg 16 326 N
6.0 m 7 409 kg 16 326 N

The fixing loads are modest; the failure is not fixing pull-out but the path behind it. The load hangs below the lintel centreline, so it applies torsion as well as vertical load. Chemical anchor pull-out, derived from bond stress with a conservative 2.0 MPa, is 6.3 kN for M10 x 100 mm and 8.3 kN for M12 x 110 mm – values that must be replaced by the anchor ETA for the actual substrate. Hollow block and aerated concrete are the two substrates where this changes the design.

Anchor Pull-out at 2.0 MPa bond (kN) Comment
M8 x 80 mm 4.0 Edge distances critical; rarely the governing check
M10 x 100 mm 6.3 Standard choice for head tracks
M12 x 110 mm 8.3 Used where the hung mass exceeds 350 kg
M16 x 125 mm 12.6 Corner posts and open corners

When bottom-rolling is the correct answer

Bottom-rolling folding sets carry the weight on a sill rail and use the head track only for guidance. The lintel problem disappears, and so does the structural engineering fee and the steel. The price is the threshold: a bottom rail needs 25-45 mm of height, which is above the French accessibility limit of 20 mm. Where a building has no accessible-route requirement, or where the opening is a retrofit and the lintel cannot be verified, bottom-rolling is usually the right decision. The porte coulissante article covers the same threshold-versus-watertightness conflict on sliding doors.

Decision Top-hung Bottom-rolling
Weight path Into the lintel Into the floor
Lintel check Mandatory Guidance only
Threshold achievable 0-5 mm flush, or 20 mm 25-45 mm
Accessibility (PMR 20 mm) Achievable Not achievable without a ramp
Floor requirement None Slab or beam under the sill; balcony edges need checking
Retrofit suitability Only with a verified lintel Generally suitable
Hardware cost index 100 85-95
Sill drainage Track can be recessed Rail must be drained or it holds water

4. Porte Pliante en Aluminium Hardware: Hangers, Wheels, Hinges and Locks

Folding hardware is the largest single cost line after the profiles, and it is where low-cost sets cut. Four checks cover almost everything: wheel contact stress, hinge grade on the traffic leaf, lock point count against wind load, and cycle duty class.

Hanger wheel contact stress: why 28 mm steel wheels fail wide leaves

A top-hung leaf is carried by two carriages with two wheels each, so four wheels share the load. Contact pressure between a steel wheel and an aluminium track is a Hertzian line contact: a = sqrt(8FR / (pi b E*)) and p = 2F / (pi a b), with b the contact width, taken as 6 mm, and E* from the two elastic moduli. The yield strength of 6063-T6 is 170 MPa, so the comparison is direct.

Leaves Leaf mass Wheel Load per wheel Contact half-width a Contact pressure p Against 170 MPa
3 109 kg 28 mm steel 349 N 0.188 mm 196.8 MPa FAIL
3 109 kg 40 mm steel 349 N 0.225 mm 164.7 MPa PASS
3 109 kg 50 mm steel 349 N 0.251 mm 147.3 MPa PASS
3 109 kg 34 mm POM 349 N 0.906 mm 40.9 MPa PASS
4 82 kg 28 mm steel 261 N 0.163 mm 170.3 MPa FAIL
4 82 kg 40 mm steel 261 N 0.195 mm 142.5 MPa PASS
4 82 kg 50 mm steel 261 N 0.217 mm 127.5 MPa PASS
4 82 kg 34 mm POM 261 N 0.784 mm 35.4 MPa PASS
5 65 kg 28 mm steel 209 N 0.145 mm 152.2 MPa PASS
5 65 kg 40 mm steel 209 N 0.174 mm 127.3 MPa PASS
5 65 kg 50 mm steel 209 N 0.194 mm 113.9 MPa PASS
5 65 kg 34 mm POM 209 N 0.701 mm 31.6 MPa PASS
6 54 kg 28 mm steel 174 N 0.133 mm 138.8 MPa PASS
6 54 kg 40 mm steel 174 N 0.159 mm 116.1 MPa PASS
6 54 kg 50 mm steel 174 N 0.177 mm 103.9 MPa PASS
6 54 kg 34 mm POM 174 N 0.639 mm 28.8 MPa PASS
7 47 kg 28 mm steel 148 N 0.123 mm 128.4 MPa PASS
7 47 kg 40 mm steel 148 N 0.147 mm 107.4 MPa PASS
7 47 kg 50 mm steel 148 N 0.164 mm 96.1 MPa PASS
7 47 kg 34 mm POM 148 N 0.591 mm 26.7 MPa PASS

The pattern is that the wheel does not fail – the aluminium track does. A 28 mm steel wheel on a bare 6063-T6 track reaches 197 MPa with three leaves and 170 MPa with four, which is at or above yield, so the track takes a permanent groove over a season of use and the leaves start to drag. Two fixes are cheap: specify a 40 mm wheel (165 MPa for the three-leaf case) or a POM wheel (41 MPa), and on coastal jobs add a stainless track insert at USD 11-19/m of track. The third fix, moving to more leaves, is the one that actually solves it, because the load per wheel falls with leaf mass.

Hinges, EN 1935 grades and the traffic leaf

The hinged joints between leaves are not door hinges in the domestic sense. Each joint carries the leaf weight and the wind reaction, and the leaf-to-leaf joint is the part that shows wear first. Specify the hinge to EN 1935 with the grade matched to leaf mass, and note that the cycle count is the controlling parameter on a commercial terrace: a 48-cover brasserie cycles a set 80-160 times a day, or 29,000-58,000 times a year, which makes a 25,000-cycle hinge a component with a two-year life.

Duty Cycles per day Cycles per year Hardware class to specify
Private terrace, 4-person household 6-12 / day 2,200-4,400 25,000
Private terrace, frequent entertaining 15-30 / day 5,500-11,000 50,000
Cafe / brasserie terrasse 80-160 / day 29,000-58,000 100,000
Hotel breakfast room / pool deck 40-90 / day 15,000-33,000 100,000
Showroom / event space 20-50 / day 7,000-18,000 50,000

Lock points: fewer leaves means more load per point

Wind on a folding set is collected by every leaf and delivered to the locking stile and the jamb, so the total force is the pressure times the whole opening area. What changes with leaf count is how many points share it: each meeting stile carries a top and bottom locking point, plus the traffic leaf lock.

Leaves Design pressure Total force on the set Locking points Load per point
2 0.8 kPa 8.8 kN 5 1766 N
2 1.2 kPa 13.2 kN 5 2650 N
2 2.0 kPa 22.1 kN 5 4416 N
4 0.8 kPa 8.8 kN 9 981 N
4 1.2 kPa 13.2 kN 9 1472 N
4 2.0 kPa 22.1 kN 9 2453 N
6 0.8 kPa 8.8 kN 13 679 N
6 1.2 kPa 13.2 kN 13 1019 N
6 2.0 kPa 22.1 kN 13 1698 N

At 2.0 kPa – a coastal or high-exposure elevation – a two-leaf set puts 4.4 kN on each locking point, well beyond the 1.5-2.5 kN that a standard espagnolette point is rated for. The same opening with six leaves puts 1.4 kN per point and is inside the normal range. This is the clearest engineering reason not to minimise leaf count on an exposed facade, and it runs against the U-value argument in section 5, which favours fewer leaves.

Hardware checklist for the purchase order

5. Uw of a Folding Set: What the Leaf Count Costs

A folding door is thermally worse than a sliding door of the same opening, for one structural reason: the leaves have to close against each other, so the opening carries a full-height frame member at every leaf joint. Two adjacent stiles, each with its own thermal break, is a worse detail than a single frame-to-glass junction.

Leaf count against U-value, at three specifications

Leaves Frame fraction Uw, 34 mm break + Low-E Uw, 34 mm break + triple Uw, 20 mm break + Low-E
2 14.6% 1.36 1.04 1.48
3 16.7% 1.43 1.11 1.56
4 18.9% 1.49 1.18 1.64
5 21.1% 1.55 1.25 1.72
6 23.3% 1.62 1.33 1.8
7 25.5% 1.68 1.4 1.88

Two conclusions come out of the same table. First, the leaf-count penalty is real but bounded: 0.32 W/m²K between two leaves and seven, on the same 4.8 m opening. Second, that penalty is the same order as the penalty for dropping from a 34 mm break to a 20 mm break (0.26-0.30 W/m²K), so a specification that spends money on a wide break and then adds leaves to solve a handling problem is spending twice. The cheapest correction for a high leaf count is the glazing: triple glazing recovers 0.26-0.30 W/m²K across the whole range.

Thermal break width and glazing: where the value is

Break width (mm) Frame Uf (W/m²K)
0 5.90
14 3.22
20 2.58
24 2.26
30 1.89
34 1.70

Uf follows a decaying exponential against break width: the first 14 mm buys 2.7 W/m²K, the step from 24 mm to 34 mm buys 0.55. The curve is the reason a 34 mm break is the export default and a 44 mm break is rarely worth it. Note that Uf is the frame value; the set value Uw is dominated by the glass area, which is why the glazing column in the table above moves Uw more per dollar than the break does. The fentre aluminium profile article derives the same relationship for aluminium windows and gives the fitted expression used here.

The meeting-stile linear transmittance penalty

Leaves dUw at psi 0.04 dUw at psi 0.07 dUw at psi 0.10 dUw at psi 0.14
2 0.008 0.015 0.021 0.029
3 0.017 0.029 0.042 0.058
4 0.025 0.044 0.062 0.088
5 0.033 0.058 0.083 0.117
6 0.042 0.073 0.104 0.146
7 0.050 0.088 0.125 0.175

The joint term alone is small – 0.10 W/m²K at psi 0.10 with six leaves – which is the honest answer to anyone claiming the meeting stiles are the whole problem. The bigger thermal effect of leaf count is the frame area, not the psi value. What psi does control is the internal surface temperature at the stile, which is where condensation is first seen.

Condensation: check the stile, not the glass

In a heated room at 20 degrees C and 45% relative humidity the dew point is about 7.9 degrees C. A stile with a 34 mm break and a psi of 0.07 sits several degrees above that in a temperate winter, but a 20 mm break with psi 0.14 at 60% indoor humidity – a kitchen-diner, which is exactly where a terrace door is – can fall below it. The specification answer is not a wider break but a lower psi detail at the joint, a warm-edge spacer, and checking the internal surface temperature rather than the Uw number.

6. Threshold, Drainage and the 20 mm PMR Rule

Threshold height sets the watertightness class

Threshold detail Height above finished floor EN 12208 class typically achieved Accessible route (PMR) Notes
Flush, recessed track 0-5 mm 1A-2A Yes Needs a drained channel in front
Low threshold 15-20 mm 4A-5B Yes, at 20 mm The usual French residential detail
Standard bottom rail 25-45 mm 6A-8A No Ramp needed, or a top-hung detail instead
Rebated into the slab 0 mm with 30 mm rebate 3A-4A Yes Requires the slab to be set out for it

The trade is direct: every millimetre of threshold buys water performance and costs accessibility. French accessibility texts apply a ressaut limit of 20 mm, or 40 mm with a 1:2 chamfer, and a clear passage commonly taken as 900 mm. A bottom-rolling folding set at 25-45 mm therefore fails the accessible-route requirement unless the terrace is designed with a ramp, which is a landscape decision and not a door decision.

Terrace drainage arithmetic: capacity is never the problem, level is

A flush threshold only works if the water that lands on the terrace cannot reach it. The inflow is Q = A x r / 3600, with A in square metres and r in mm/h, giving litres per second. The drain capacity is an orifice calculation, Q = Cd x A x sqrt(2gh), with Cd taken as 0.62.

Terrace area 50 mm/h 75 mm/h 108 mm/h 150 mm/h
8 m2 0.11 0.17 0.24 0.33
12 m2 0.17 0.25 0.36 0.50
20 m2 0.28 0.42 0.60 0.83
30 m2 0.42 0.62 0.90 1.25

Terrace inflow in litres per second. A 12 m2 terrace in a 108 mm/h convective storm delivers 0.36 L/s.

Channel length Grating width Water head Capacity at 25% open area
2.4 m 60 mm 5 mm 6.99 L/s
2.4 m 60 mm 10 mm 9.89 L/s
2.4 m 60 mm 20 mm 13.98 L/s
2.4 m 80 mm 5 mm 9.32 L/s
2.4 m 80 mm 10 mm 13.18 L/s
2.4 m 80 mm 20 mm 18.64 L/s
2.4 m 100 mm 5 mm 11.65 L/s
2.4 m 100 mm 10 mm 16.48 L/s
2.4 m 100 mm 20 mm 23.30 L/s
3.6 m 60 mm 5 mm 10.49 L/s
3.6 m 60 mm 10 mm 14.83 L/s
3.6 m 60 mm 20 mm 20.97 L/s
3.6 m 80 mm 5 mm 13.98 L/s
3.6 m 80 mm 10 mm 19.77 L/s
3.6 m 80 mm 20 mm 27.96 L/s
3.6 m 100 mm 5 mm 17.48 L/s
3.6 m 100 mm 10 mm 24.72 L/s
3.6 m 100 mm 20 mm 34.95 L/s
4.8 m 60 mm 5 mm 13.98 L/s
4.8 m 60 mm 10 mm 19.77 L/s
4.8 m 60 mm 20 mm 27.96 L/s
4.8 m 80 mm 5 mm 18.64 L/s
4.8 m 80 mm 10 mm 26.36 L/s
4.8 m 80 mm 20 mm 37.28 L/s
4.8 m 100 mm 5 mm 23.30 L/s
4.8 m 100 mm 10 mm 32.96 L/s
4.8 m 100 mm 20 mm 46.61 L/s
The smallest channel in the table, 2.4 m at 60 mm with 5 mm of head, passes 4.4 L/s against a terrace inflow of 0.36 L/s. Capacity is an order of magnitude above demand, so sizing the drain is not the engineering task. The task is the level: the grate must sit below the threshold, the terrace must fall away from the door at 1-2%, and the channel must have an access point for cleaning. A linear drain costs USD 30-62 per metre and is the cheapest item in the package – and the one whose absence is noticed in the first sustained rainfall.

The same reasoning is set out for sliding doors in the porte coulissante article and for veranda roofs in the veranda drainage article: in both cases the failure is level and maintenance, not capacity.

Sealed joint length: why folding sets leak more than sliding doors

Watertightness depends on the total length of seal that has to stay compressed. A sliding door has the perimeter plus one meeting stile. A folding set has the perimeter plus two full-height seals at every leaf joint, and each of those joints moves every time the set is opened.

Leaves Sealed length, folding Sealed length, 2-leaf sliding Ratio
2 18.8 m 19 m 1.00x
4 28.0 m 19 m 1.49x
6 37.2 m 19 m 1.98x
7 41.8 m 19 m 2.22x

A six-leaf set has 37.2 m of seal against 18.8 m for a two-leaf sliding door of the same opening, roughly double, and every moving joint is a compression seal that has to survive the cycle duty from section 4. This is the mechanical reason the service call rate on folding sets runs at 1.4-1.9 times a sliding door over the first 24 months.

7. Glazing, Safety and Acoustics

Glass build-ups and areal mass

Code Build-up Areal mass (kg/m2) Ug (W/m2K) When specified
F 6-16Ar-6, no coating 30.0 2.60 Interior or unheated enclosure only
D 6-16Ar-6 Low-E 30.0 1.10 Export default for heated buildings
T 6-12Ar-6-12Ar-6 Low-E 45.0 0.72 Cold climates and RE2020-driven projects
A 6-1.52PVB-6 / 16Ar / 6 Low-E 46.6 1.08 Road noise, or overhead-adjacent leaves

Glass mass is 2.5 kg/m² per millimetre of thickness, so the build-up is a direct input to the hanger load in section 4 and the lintel load in section 3. Upgrading from Low-E double to triple adds 15 kg/m², which on a 4.8 m six-leaf set is an extra 98 kg hanging from the head – a 30% increase in the load the lintel has to be checked for. This is the most common specification change that is made without rechecking the structure.

Glass thickness, wind span and human impact

Each leaf is a four-sided supported pane spanning between its own rails and stiles, so the span is the leaf glass width from section 2, not the opening width. Under EN 16612 the resistance is checked with the plate bending expression, and the stress varies with the square of the span, so halving the leaf width roughly quarters the stress. This is a second reason more leaves is the safer answer on an exposed elevation. Where a leaf is within reach of a floor level, or where the set gives access to a pool, the inner pane is specified as laminated and the leaves are toughened to EN 12150 with heat-soak testing to EN 14179; the spontaneous breakage rate of nickel sulphide inclusions is 0.1-0.2%, which on a 40-set project is a call-out every year or two.

Acoustics: the gap arithmetic

Leaves Sealed length Continuous gap Gap as share of area Rw from a 36 dB leaf Rw from a 31 dB leaf
2 18.8 m 0.2 mm 0.034% 32.3 dB 29.5 dB
2 18.8 m 0.5 mm 0.085% 29.6 dB 27.8 dB
2 18.8 m 1.0 mm 0.170% 27.1 dB 26.0 dB
2 18.8 m 2.0 mm 0.341% 24.4 dB 23.8 dB
6 37.2 m 0.2 mm 0.067% 30.3 dB 28.3 dB
6 37.2 m 0.5 mm 0.168% 27.1 dB 26.1 dB
6 37.2 m 1.0 mm 0.337% 24.4 dB 23.8 dB
6 37.2 m 2.0 mm 0.674% 21.6 dB 21.2 dB

A gap is treated as an area with a transmission coefficient of 1, so the resulting Rw is -10 log of the area-weighted sum. A 1 mm continuous gap along 37.2 m of seal is 0.337% of the opening area and it takes a 36 dB leaf down to 24.4 dB. That is a 11.6 dB loss for a defect that is invisible from a metre away. It is also why acoustic performance on a folding set is a commissioning item, not a product item: the leaf build-up matters far less than whether the meeting stiles actually compress.

8. Profile, Alloy and Coating

Why folding doors are 6063 and not the stronger alloys

Alloy and temper Rp0.2 (MPa) Allowable stress, gammaM1 = 1.10 (MPa) Typical extrusion pressure (MPa) Used for folding sets
6060-T6 150 136 250-280 Yes, simple profiles
6063-T6 170 155 280-320 Yes, the export default
6061-T6 240 218 400-460 Rarely; pressure limit
6082-T6 260 236 420-480 Rarely; pressure limit
6005A-T6 215 195 380-420 Sometimes for heavily loaded stiles

The choice is not about strength. A folding leaf is deflection-controlled, not stress-controlled, and the stiles reach their L/200 or L/300 limit while the stress is still below 40% of allowable. The choice is about extrudability and surface quality. On a 152 mm billet, a 780 mm² folding profile has an extrusion ratio of about 23, and the press force is the extrusion pressure times the billet area: roughly 524 tonnes for 6063 against 815 tonnes for 6082. That difference removes roughly half the factories that can quote the profile, which shows up as price and as lead time rather than as a number on a datasheet.

T5 against T6 is the second decision. T5 is air-quenched and naturally aged, giving Rp0.2 of 110 MPa; T6 is water-quenched and artificially aged at 170-180 degrees C for 6-8 hours, giving 170 MPa. Because the leaf is deflection-controlled, T5 is sufficient for the frame; T6 is specified where the profile is loaded in bearing, which on a folding set means the hanger fixings and the hinge seats.

Wall thickness and the tolerance that actually matters

Element Wall thickness (mm) Why
Outer frame 1.8-2.0 Fixing pull-out and transport handling
Leaf stiles and rails 1.8-2.2 Hinge and hanger bearing, corner crimping
Meeting stiles 2.0-2.2 Locking point bearing and racking stiffness
Head track 2.5-3.0 Carries the set; fixings at 400 mm
Sill / bottom rail 2.5-3.0 Bottom-rolling: carries the set and foot traffic
The tolerance that causes field failures is not the profile outline, which is covered by EN 755-9 at +/- 0.15-0.35 mm. It is the knurling groove that grips the polyamide thermal break strip, held at +/- 0.05 mm. A groove worn 0.1 mm oversize by a tired tool does not bite, the composite shear strength falls, and the failure is delayed: the leaf drops over a heating season and then the lock will not engage. Ask for the shear test report by die batch, not by profile series.

Coating and corrosivity category

Standard / label What it covers Typical film or class Where specified
Qualicoat Class 1 Powder coating, inland 60-80 microns Standard inland orders
Qualicoat Class 2 (Seaside) Powder coating, coastal 60-80 microns + pre-treatment Within 3 km of coast or pool
Qualanod AA15 / AA20 / AA25 Anodising 15 / 20 / 25 microns Architectural, high UV
AAMA 2604 / 2605 US performance spec 5 / 10 year Florida North American projects
Qualideco Sublimated wood effect Over Qualicoat base Residential, wood-look
ISO 9223 C2-C5-M Corrosivity category C2 inland to C5-M marine Selecting the coating class

ISO 9227 neutral salt spray is a batch ranking test, not a life prediction: a 1,000 hour result compares two batches to each other and says nothing about a 20-year facade. On a folding set the corrosion risk is concentrated in the sill and the bottom of the meeting stiles, where water sits, and in the fasteners. A2-304 stainless is adequate inland; A4-316 is required in C4 and C5-M and beside pools. Brass and copper are anodic to aluminium and must not be used in contact with the frame, and wet concrete at pH 12-13 attacks aluminium directly, so the sill must be isolated from fresh mortar.

9. CE, DoP and What Each Certificate Does Not Cover

EN 14351-1, AVCP System 3 and the tested specimen

An external pedestrian door set without fire or smoke properties is covered by EN 14351-1 under AVCP System 3: the factory declares performance on the basis of initial type testing and factory production control, and issues a declaration of performance under CPR 305/2011. The declaration is only as good as the specimen that was tested, and this is where folding door documentation needs checking.

AEV classes and the A/B series trap

Property Standard Class meaning Typical folding set
Air permeability EN 12207 Class 0 (not tested) to 4 Class 2-3
Watertightness EN 12208 A series 1A-9A, B series 1B-7B 4A-6A
Wind resistance EN 12210 C1-C5 with deflection A/B/C C3-C5
Operating effort EN 12046-1 Measured force to move the leaf Reported on request
Mechanical durability EN 12400 / EN 1191 Cycle class Must be stated on the order
EN 12208 has two series and the number does not carry across. Class 7A is 600 Pa; class 7B is 300 Pa, and 7B is the top of the unprotected series. A supplier quoting “class 7” has reported a protected test condition that the installed door may not reproduce. Always ask for the letter. The ventanas de aluminio article gives the same warning for aluminium windows and shows how EN 12208 and AAMA figures compare.

Burglar resistance: RC classes and the N suffix

Class Attack tool and time Feasible on a folding set
RC1N / RC1 Body force only, 0 / 3 min Yes
RC2N / RC2 Screwdriver, pliers, wedge, 3 / 15 min RC2 with laminated glass
RC3 Crowbar and second screwdriver, 20 min Yes, with a full hardware package
RC4 Axe, hammer, chisel, cordless drill, 30 min Rarely; cost is disproportionate

The N suffix means the glazing was not attack-tested. A folding set that is 76% glass and declared RC2N has no meaningful burglar rating, because the glass is the obvious route. The class is also a system property: the lock seats, the cylinder to EN 1303, the hinges to EN 1935, the glazing beads and the panel core all have to be rated, so changing the door leaf alone does not change the class. For folding sets the weak point is the meeting stile, and it needs a locking point top and bottom at every joint, not just at the traffic leaf. Hardware for folding sets is covered by EN 1527; ask for the test report against that standard.

10. Production Flow and the Inspection Points That Matter

Twelve steps and where the days go

Step Days Share of lead time Note
Drawings and approval 5-7 18% The only step the buyer can compress
Extrusion 3-5 11% Die already exists for standard series
Thermal break assembly 2-3 7% Knurling and crimping; see section 8
Cutting and machining 2-3 7% Handing is fixed here
Surface treatment 2-3 7% Pre-treatment quality governs coating life
Powder coating / anodising 2-3 7% Batch colour consistency
Glazing unit production 3-5 11% Often bought in
Assembly of leaves 2-3 7% Corner crimping and sealing
Hardware fitting 1-2 4% Hangers, hinges, locks
Pre-assembly test fold 1 4% Highest value inspection step
Packing 1-2 4% Crate engineering
Container loading 1-2 4% See section 12

Total is 26-38 days against a quoted 30-45, and the buyer holds 18% of it. Approving drawings in 48 hours instead of seven days is the single largest saving available on the schedule, and it costs nothing.

Inspection points that catch the expensive errors

The aluminium window supply article sets out the same inspection logic for aluminium windows, including the dry-assembly photograph step and why it outranks dimensional spot checks.

11. FOB Pricing by Configuration and Volume

Seven configurations at four order sizes

Configuration (FOB USD/m²) 30 m2 (1-2 sets) 100 m2 300 m2 800 m2
C1 2-panel, 20 mm break, float double $148 $139 $130 $121
C2 3-panel, 24 mm break, Low-E $177 $166 $156 $145
C3 4-panel, 30 mm break, Low-E $193 $181 $170 $158
C4 5-panel, 34 mm break, Low-E $211 $198 $186 $173
C5 6-panel, 34 mm break, Low-E, warm edge $218 $205 $192 $179
C6 6-panel, 34 mm break, triple Low-E $266 $250 $234 $218
C7 6-panel, 34 mm break, acoustic laminated $252 $237 $222 $207

The spread between the cheapest and the dearest configuration is USD 104/m² at the 30 m² tier and USD 85/m² at 800 m², and almost all of it is glazing and break width rather than hardware. The leaf-count effect is smaller than most buyers expect: going from four to six leaves adds USD 13/m², which is less than the warm-edge spacer it is often traded against. What leaf count does change is the structural package – the lintel in section 3 is not in this price.

What the FOB price includes, and what it does not

Included in FOB Not included
Profiles, thermal break, gaskets Lintel, steel beam or structural works above the opening
Glazing units as specified Installation labour and site equipment
Hangers, hinges, locks, handles Crane or glass lifting equipment
Factory pre-assembly and test fold Linear drain, terrace falls, landscaping
Export crating to the port Freight, insurance, duty, anti-dumping duty
Standard documentation Project calculations and engineered drawings – USD 8-18/m² below 150 m²
Spare hardware if ordered Local certification or NF-type assessment
The most common false comparison in this product is between a Chinese FOB price and a European supply-and-install price. The European number normally includes the structural check, the project documentation and the installation. The FOB number includes none of them. The landed cost model in section 13 puts them on the same basis.

Options priced per square metre or per set

Option Cost (USD/m² unless stated)
Qualicoat Class 2 (Seaside) powder $8-14
Anodising Qualanod AA25 instead of powder $18-30
A4-316 stainless fasteners and track insert $9-16
Stainless steel running track insert $11-19
Concealed multi-point locking on every meeting stile $12-22
RC2 / RC3 hardware package $26-55
Low threshold detail (recessed 5 mm + linear drain) $30-62
Traffic leaf (porte de service) as 4th/5th panel $45-95
Trickle / corner post (opening without a jamb) $120-260
Acoustic laminated inner pane $30-55
Triple glazing upgrade $55-78
Integrated venetian blinds in the glazing cavity $75-130
Curved / angled bay configuration $90-165
Reduced stile sightline 35 mm (slim series) $22-40
Steel-reinforced head beam $12-26
Pre-assembled panel shipping (glass fitted) $6-12
Spare hardware kit (2% of sets) $4-9
Project documentation pack (DoP, calcs, drawings) $8-18

Items marked as set-level pricing – the traffic leaf at USD 45-95 and the corner post at USD 120-260 – are the ones that most often appear as a variation order, because they are handed decisions that have to be made before extrusion. The door and window accessories article covers the hardware options for sliding and folding accessories in more detail, including roller and track specification.

12. MOQ, Lead Time, Payment, Packing and Warranty

Commercial terms

Term Standard offer Notes
MOQ 30 m² or 6 sets Below this the die and set-up cost dominates
Lead time 30-45 days after drawing approval Add 7-10 days for anodising
Payment 30% deposit, 70% before shipment L/C at sight accepted above USD 50,000
Incoterms FOB Shenzhen or Guangzhou (Nansha) CIF available on request
Sample set One set at 1.5x unit price Credited against the first order above 100 m²
Packing Plywood crate, leaves nested flat Crate dimensions in the table below
Warranty 10 years coating, 5 years hardware Excludes coastal sites without Class 2
Spare parts 2% hardware kit recommended Rollers, hinges, gaskets, one lock
Documentation DoP, test reports, drawings Project calculation pack: USD 8-18/m²

Container loading: volume is the limit, not weight

Opening Leaves Crate (L x W x H) Crate volume Crate mass Sets by volume Sets by payload Sets per 40HQ Area per container
3.0 m 3 2.34 x 1.04 x 0.41 m 0.98 m3 249 kg 69 94 69 (volume) 478 m2
3.6 m 4 2.34 x 0.94 x 0.49 m 1.07 m3 290 kg 63 81 63 (volume) 524 m2
4.2 m 4 2.34 x 1.09 x 0.49 m 1.25 m3 331 kg 54 70 54 (volume) 527 m2
4.8 m 5 2.34 x 1.00 x 0.58 m 1.34 m3 372 kg 50 63 50 (volume) 559 m2
4.8 m 6 2.34 x 0.84 x 0.66 m 1.29 m3 372 kg 52 63 52 (volume) 580 m2
6.0 m 6 2.34 x 1.04 x 0.66 m 1.60 m3 454 kg 42 51 42 (volume) 585 m2
6.0 m 7 2.34 x 0.90 x 0.75 m 1.56 m3 454 kg 43 51 43 (volume) 601 m2

Folding sets are volume-limited on every configuration tested: a 40 ft high-cube takes 42-69 sets, using the whole 68 m³ of usable volume while using only 70-85% of the payload. That conclusion has a practical consequence, because a light-out, volume-out container is the ideal partner for a heavy cargo: sharing a container with tiles, stone or hardware can cut the freight allocation by 8-12%. Knock-down is not available for glazed folding leaves, so the levers are crate height, separator thickness and whether the glass is factory-fitted.

Below 8-10 m³ – roughly five sets – LCL freight runs at 3.0-3.5 times the per-unit cost of a full container. If the first order is small, either consolidate with another product from the same factory or accept that the freight is a sample cost, not a unit cost.

13. Landed Cost into the EU and the Anti-Dumping Lever

A worked model on a six-leaf set

Step USD/m² Note
FOB Shenzhen $212 C5 configuration, 34 mm break, Low-E
Sea freight and insurance $14.2 40HQ, volume-limited load
CIF European port $226.2
Customs duty, 6% $12.7 Classification-dependent
EU anti-dumping on aluminium extrusions $47.1 Rate depends on the exporter
Landed at port $286.0
Installation $48 Crew of three, two sets per day
Installed total $334.0

Against a European supply-and-install figure of USD 480/m² for an equivalent thermally broken aluminium folding set, the installed total of USD 334/m² is 30.4% lower. The saving is real but it is smaller than the FOB comparison suggests, and most of the difference between the two numbers is freight plus duty plus anti-dumping, which together add USD 74/m² – more than the entire difference between the cheapest and the most expensive configuration in section 11.

Sensitivity: the tariff lever is bigger than the product lever

Anti-dumping rate Duty (USD/m²) Landed Installed Saving vs local
0.0% $0.0 $238.9 $286.9 40.2%
6.0% $12.7 $251.6 $299.6 37.6%
12.1% $25.7 $264.6 $312.6 34.9%
22.2% $47.1 $286.0 $334.0 30.4%
32.1% $68.1 $307.0 $355.0 26.0%
The anti-dumping line moves the installed price by roughly USD 65/m² across its plausible range. That is larger than the difference between any two configurations in section 11, and roughly four times the sea freight. The practical rule is the same one that applies to aluminium windows and verandas: settle the customs classification and the exporter rate first, because it moves the price more than any product decision, and then optimise the product. The double glazed windows article reaches the same conclusion for aluminium windows into the EU.

14. Installation Sequence and Commissioning

Nine steps, in order

  1. Verify the lintel before anything is unpacked: section capacity, deflection class and the fixing substrate. Record it.
  2. Set the head track on a continuous packing line and shim to the lintel at 400 mm centres; the track must not be used to pull a wavy lintel straight.
  3. Fix the jambs and the sill, checking diagonal and level; dry-fit the frame without glass first.
  4. Hang the leaves from the stacking side outwards, two people per leaf up to 80 kg, four beyond that.
  5. Fit the hinge joints between leaves and set the leaf-to-leaf gap before tightening.
  6. Set the locking points and the keeps; each stile must compress evenly top and bottom.
  7. Fit gaskets, then the drainage channel and the external flashing or membrane terminations.
  8. Glaze if the leaves were shipped unglazed, using setting blocks and not gluing the unit to the frame.
  9. Commission: cycle the set five times under load, record the operating force, pour water on the threshold and watch where it goes.

Commissioning checks that predict the first year

Check Method Pass criterion
Track deflection Straightedge along the track with the set hung No gap over 1 mm/m
Leaf-to-leaf gap Feeler gauge at three heights Even within 1 mm top to bottom
Operating force Spring balance at the handle, EN 12046-1 Within the declared class
Lock engagement Cycle and check each point Every point carries load, none free
Threshold drainage Pour water on the terrace side Water leaves; no standing water at the track
Seal continuity Paper test: pull a strip through each seal Resistance at every point
Cycle test Five full cycles loaded No binding, no drift in leaf alignment
The paper test on the seals is the cheapest acoustic and air-tightness check available and it takes two minutes per set. Section 7 shows what a 1 mm gap costs: 11.6 dB.

15. Failure Modes: Which Ones Are Bought, Not Installed

Six failure modes and where they are decided

Failure Symptom Root cause Decided at
Leaves dragging after one season Increasing operating force, then binding 28 mm steel wheel on a bare aluminium track, contact pressure above yield Specification
Leaf drop at the lock Lock will not engage after a heating season Knurl groove oversize, composite shear strength loss Die batch
Head track sagging Visible gap at the head, leaves jump Lintel not checked; 100 x 50 x 3 gives 19.6 mm on 4.8 m Design
Water at the threshold Staining inside after sustained rain Level, not capacity: no drain, or terrace falls toward the door Design
Glass upgrade without a structural recheck Track deflection after a triple-glazing change +15 kg/m² on the hung load Variation order
Corrosion at the sill Filiform corrosion under the coating, seized rollers A2 fasteners in C4-C5-M, or wet concrete contact Specification

Four of the six are decided before the set is manufactured. That is the pattern across all wide-opening products: the expensive failures are specification errors, and installation errors are the cheaper ones to fix.

What to put in the purchase order

16. Two Delivered Projects

Bordeaux brasserie terrace: eight top-hung sets

Item Value
Sets / opening 8 sets, 4.2 x 2.3 m, 5 leaves, top-hung
Total glazed area 77.3 m²
Configuration 34 mm break, 6-16Ar-6 Low-E, warm edge, traffic leaf
Structure Existing steel lintel verified and upgraded to 150 x 100 x 5 RHS
Threshold 20 mm low threshold with a 100 mm linear drain outside
Coating Qualicoat Class 2, A4-316 fasteners, site 12 km from the coast
FOB $214/m²
CIF $228.2/m²
Duty 6% + anti-dumping 22.2% $12.8 + $47.5/m²
Landed $288.5/m²
Installed $336.5/m²
Local equivalent $480/m² installed
Saving 29.9%, USD 11,086
18-month record 3 service calls (2 lock adjustments, 1 roller), no water ingress

The linear drain was USD 42/m and USD 1,344 in total, the smallest line in the package. It is also the reason the 20 mm threshold has no water complaints across two winters. The lintel upgrade was the largest single non-door cost and it was identified before the order, which is the only way it stays cheap.

Lyon residential retrofit: six bottom-rolling sets

Item Value
Sets / opening 6 sets, 3.0 x 2.3 m, 4 leaves, bottom-rolling
Total glazed area 41.4 m²
Configuration 30 mm break, 6-16Ar-6 Low-E, 25 mm bottom rail
Structure Existing concrete lintel not verifiable; load taken on the slab instead
Why bottom-rolling Avoided structural engineering at USD 1,400-2,600 per opening
Threshold 25 mm, private house with no accessible-route requirement
FOB $196/m²
CIF $210.2/m²
Duty 6% + anti-dumping 22.2% $11.8 + $43.5/m²
Landed $265.5/m²
Installed $313.5/m²
Local equivalent $445/m² installed
Saving 29.6%, USD 5,445
18-month record 2 service calls, both sand in one bottom rail

The decision in this project was structural, not product-led. Bottom-rolling cost 6% less in hardware and removed a lintel verification that would have consumed most of the saving. The price was a 25 mm threshold, acceptable here because the house has no accessibility obligation; on a project with an accessible route the same opening would have needed a top-hung set and the structural works that come with it.

17. Porte Accordon Against Porte Coulissante, Galandage and Porte-Fenetre

Ten rows that matter

Property Porte accordon (folding) Porte coulissante (sliding) Porte a galandage Porte-fenetre
Clear opening of the structural bay 88-96% 50-67% (2-panel) / 67-75% (3-rail) 92-95% (pocket) 100% (no fixed panel)
Frame area fraction (4.8 m opening) 18-23% 12-16% 14-18% 10-14%
Uw, 34 mm break + Low-E 1.48-1.62 1.35-1.48 1.40-1.55 1.30-1.45
Air permeability, EN 12207 Class 2-3 Class 3-4 Class 2-3 Class 3-4
Watertightness, EN 12208 4A-6A 6A-8A 3A-5A 7A-8A
Sealed joint length (4.8 x 2.3 m) 37-49 m 19-24 m 24-30 m 15-19 m
Threshold height available 0-20 mm (top-hung) / 25-45 mm (bottom-rolling) 20-45 mm 0-5 mm 15-25 mm
Structural demand above the opening Lintel sized for the hung load None (weight on sill) Pocket wall must be built None
Hardware count per bay 4-10 hangers + 2-6 hinges per leaf 4-8 rollers 2-4 rollers 3 hinges
Service call rate, first 24 months 1.4-1.9x a sliding door Baseline 1.0x 1.2-1.5x 0.7-0.9x
FOB index (per m2) 118-155 100 150-190 85-110

What the table actually decides

Most of these rows are noise once four questions are answered. Read the table only against these:

  1. Is there a verifiable lintel, or a budget to create one? If not, folding top-hung is off the list – take bottom-rolling or sliding.
  2. Is an accessible route required through the opening? If yes, the threshold row decides it: folding top-hung at 0-20 mm, or galandage, and bottom-rolling folding is out.
  3. Is the opening cycled more than about 30 times a day? If yes, the service call row and the hardware cycle row dominate every thermal row in the table.
  4. Is the opening above roughly 6 m, or is it a corner? If yes, two sets or a corner post is the decision, and leaf count is secondary.

For the sliding alternative in detail, the porte coulissante article covers roller engineering, drainage and large openings; for the glazed-door alternative, the front entry doors article covers hinged configurations and hardware.

18. RFQ Checklist, French-English Glossary and Standards Index

Eight technical questions and eight commercial questions

Technical Commercial
Structural opening, finished opening and clear passage required Quantity in sets and in square metres
Leaf count, stacking side, traffic leaf yes or no Target FOB port and Incoterms
Glazing build-up and Ug required Delivery date and whether it is fixed
Design wind pressure and the exposure category Payment terms and whether L/C is available
Threshold height and accessibility requirement Spare parts kit yes or no
Uw or Ud target, and the psi value required at the joints Documentation pack required
Coating class and ISO 9223 category of the site Warranty terms in writing
Cycle duty: openings per day Sample set before the production order

French-English glossary

French English
Porte accordon / porte accordeon Folding door; leaves hinged in a chain and stacked to one side
Porte pliante / portes pliantes Folding door; plural form used for multi-leaf sets
Porte a galandage Sliding door that parks inside a wall pocket
Porte de service Traffic leaf; a single leaf that opens like a normal door
Vantail Leaf / panel
Dormant Fixed outer frame
Tableau Structural reveal of the masonry opening
Cote de passage Clear passage width when open
Cote d encombrement Overall occupied dimension when stacked
Linteau Lintel above the opening
Seuil / seuil PMR Threshold / accessible threshold (20 mm rule)
Barrette a rupture de pont thermique Polyamide thermal break strip
Profil a rupture de pont thermique Thermally broken profile
Meneau Mullion / meeting stile between leaves
Joint de battement Meeting stile seal
Poignee-cle / cremone Espagnolette / multi-point lock
Chariot / galet Carriage / roller hanger
Rail de roulement Running track
Pose en applique / en tunnel / en feuillure Face-fix / in-reveal / rebated installation
DoP (Declaration de Performance) Declaration of Performance under CPR 305/2011

Standards index

Standard What it covers
EN 14351-1 Windows and doors, product standard; AVCP System 3 for non-fire external doors
EN 12207 Air permeability, classes 0-4
EN 12208 Watertightness, A and B series (7A = 600 Pa, 7B = 300 Pa)
EN 12210 Wind resistance, classes C1-C5 with deflection limits A/B/C
EN 1527 Building hardware for sliding doors and folding doors; requirements and test methods
EN 1935 Single-axis hinges; grades 11-14 by door mass and cycles
EN 12400 / EN 1191 Mechanical durability classification and the cycling test method
EN 13126 Hardware for windows and door-height windows
EN ISO 10077-1 / -2 Thermal transmittance of frames and of the frame/glass junction
EN 673 Determination of the Ug of glazing units
EN 16612 Glass lateral load resistance by calculation
EN 1279-3 Gas leakage rate for insulating glass units
EN 12150 / EN 12600 Thermally toughened glass / pendulum impact classification
EN 14179 Heat-soak testing of toughened glass
EN 1627 / 1630 Burglar resistance classes RC1N-RC6
EN 1303 / EN 1906 Cylinder locks / lever furniture
EN 755-2 Mechanical properties of extruded aluminium alloys
EN 1999-1-1 (Eurocode 9) Design of aluminium structures; partial factor 1.10
EN 1991-1-4 / -3 Wind and snow actions
Qualicoat / Qualanod / Qualideco Coating quality labels for powder, anodising and sublimation
ISO 9223 / ISO 9227 Corrosivity categories / neutral salt spray (ranking, not life prediction)
NF DTU 36.5 French installation code for windows and doors
French accessibility texts (PMR) Ressaut <= 20 mm (40 mm with a 1:2 chamfer); clear passage commonly 900 mm
CPR 305/2011 Construction Products Regulation; basis of the DoP and CE marking

Related articles on this site: aluminium folding door supply, accordion door manufacture, fenetres coulissantes en aluminium, fentre aluminium profile systems and veranda and sunroom drainage.