Home > Folding Doors > Porte Accordon Export in China: Portes Pliantes en Aluminium, Accordion Doors Folding Geometry, FOB Pricing
Porte Accordon Export in China: Portes Pliantes en Aluminium, Accordion Doors Folding Geometry, FOB Pricing
Porte accordon with thermally broken aluminium leaves stacked to one side, flush threshold detail, residential terrace.
A porte accordon is a folding door set: a chain of hinged leaves carried along a head track, stacked against one jamb when open. In the Chinese export build the leaves are 6063-T6 thermally broken aluminium carrying double or triple Low-E glazing, with the whole set weighing 200-460 kg depending on leaf count and glass build-up. This article documents the geometry, the structural demand on the lintel above the opening, hanger wheel contact stress, thermal transmittance by leaf count, threshold and drainage arithmetic, certification scope, FOB pricing by configuration, container loading, landed cost into the EU, installation sequence and two delivered projects, in USD and SI units.
1. Portes Pliantes, Porte Accordeon and Galandage: What the Order Actually Is
Three French product names are used for wide glazed openings and they are not interchangeable. Getting the name wrong on a purchase order changes what is shipped, because the hardware, the threshold and the structural demand above the opening are different in each case.
Terminology: what each name refers to
French term
English equivalent
Leaves
Weight carried by
Typical threshold
Porte accordon / porte accordeon
Folding / accordion door
2-7
Head track (top-hung) or sill rail (bottom-rolling)
0-45 mm
Portes pliantes
Folding doors (plural)
2-7
Head track or sill rail
0-45 mm
Porte pliante en aluminium
Aluminium folding door
2-7
Head track or sill rail
0-45 mm
Porte a galandage
Sliding door with wall pocket
1-2
Bottom rollers
0-5 mm
Baie vitree coulissante
Sliding patio door
2-3
Bottom rollers
20-45 mm
Porte-fenetre
Glazed French door / casement door
1-2
Hinges
15-25 mm
Porte de service (vantail principal)
Traffic leaf
1
Hinges
Same as set
The last row is the one that is most often missed. A folding set can include one leaf that opens like a normal hinged door, so that a winter errand across the terrace does not require folding the whole set. Specifying it costs USD 45-95 per set and it removes most of the cycle wear from the folding hardware; without it every trip cycles the full chain.
Where each type is specified
Restaurant and brasserie terraces: folding, 4-6 leaves, opened for the whole service and closed at night. Cycle duty is the controlling specification, not U-value.
Private house living room to terrace: folding, 3-6 leaves, with a traffic leaf. Threshold and drainage are the controlling specifications.
Veranda and patio enclosure: folding is often chosen for the ventilation area it gives, but the enclosure roof decides the water load that the threshold must survive – see the drainage arithmetic in the veranda roof and drainage article.
Hotel pool deck and breakfast room: folding, 5-7 leaves, coastal coating class and A4 stainless hardware.
Retrofit where the lintel cannot be verified: bottom-rolling folding, or a sliding door instead, because neither puts load into the lintel.
For the sliding alternative, the porte coulissante article covers rollers, drainage and large-opening splitting in detail; the comparison in section 17 sets out which of the two the project actually needs.
Reading a French specification: four dimension bases
A French cahier des clauses techniques particulieres (CCTP) uses four different dimension bases for the same opening. Measuring the masonry opening and cutting to the finished size is a 40-60 mm irreversible error, and it is the single most common reason a folding set does not fit on site.
Dimension base
Meaning
What it is used for
Trou nu de maçonnerie
Structural masonry reveal
Site measure; what the builder leaves
Tableau
Reveal of the finished opening
Setting the frame width
Cote de passage
Clear passage width when open
Accessibility and furniture clearance
Cote d’encombrement
Overall occupied footprint when stacked
Checking the opening is not blocked by the stack
Dimensions finies
Manufactured frame size
What the factory cuts to
Write all four on the order. The cote de passage is the one that decides accessibility compliance, and for a folding set it is not the structural width: the stacked leaves stay inside the opening. Section 2 quantifies how much they take.
Leaf count is the one decision that drives everything else in a folding set: leaf width, leaf mass, hardware duty, frame fraction, U-value, price and the number of people needed to carry the leaves on site. Fewer leaves means a wider clear opening and a lower U-value, but each leaf is heavier and each lock point carries more wind load.
Leaf count against clear opening, frame fraction and U-value
Leaves
Leaf glass width
Leaf mass
Set mass
Stack width
Clear opening
Frame fraction
Uw (34 mm + Low-E)
2
2.29 m
164 kg
329 kg
0.09 m
95.7%
14.6%
1.36
3
1.49 m
109 kg
328 kg
0.17 m
94.0%
16.7%
1.43
4
1.09 m
82 kg
328 kg
0.26 m
92.2%
18.9%
1.49
5
0.85 m
65 kg
327 kg
0.34 m
90.4%
21.1%
1.55
6
0.69 m
54 kg
327 kg
0.42 m
88.6%
23.3%
1.62
7
0.57 m
47 kg
326 kg
0.51 m
86.9%
25.5%
1.68
The pattern is monotonic and it is a genuine trade-off. Going from 2 leaves to 7 on a 4.8 m opening drops the clear opening from 95.7% to 86.9% and raises Uw from 1.36 to 1.68 W/m²K, because every added leaf brings two more meeting stiles. In exchange the leaf mass falls from 164 kg to 47 kg, which is the difference between a glass trolley and two people with suction cups.
The leaf width band that hardware is designed for
Folding door hardware is engineered for leaf widths of roughly 0.55-1.10 m. Outside that band two things happen at once: the hanger load per wheel rises, and the leaf becomes too heavy to handle without equipment. The table below is the same 4.8 m opening with double glazing, classified by the handling method the mass demands.
Leaves
Leaf glass width
Leaf mass
Handling on site
2
2.29 m
164 kg
glass trolley / lifting frame
3
1.49 m
109 kg
4 persons + suction cups
4
1.09 m
82 kg
4 persons + suction cups
5
0.85 m
65 kg
2 persons + suction cups
6
0.69 m
54 kg
2 persons + suction cups
7
0.57 m
47 kg
2 persons + suction cups
Two leaves on a 4.8 m opening is a valid drawing and a bad product decision: a 164 kg leaf needs a glass trolley, exceeds the wheel contact limit for a standard 28 mm steel wheel (section 4), and puts 2.2 kN on each lock point at 1.2 kPa wind. Four to six leaves is the working band for this width.
Recommended leaf count by opening width
Opening width (m)
Leaves
Leaf glass width (m)
Leaf mass, Low-E (kg)
Why
2.4
2
1.09
82
Two leaves still inside the handling band
3.0
3
0.89
69
Widest leaf that two people can carry
3.6
3-4
1.09 / 0.79
82 / 60
4 leaves preferred if the set is cycled daily
4.2
4
0.94
71
Balanced; stack takes 0.26 m
4.8
5-6
0.85 / 0.69
65 / 54
Standard export configuration
6.0
6-7
0.87 / 0.79
73 / 66
Above 6 m, split into two sets or add a corner post
Above roughly 6.0 m the set should be split in two, or built with an open corner post so the two halves meet without a jamb. A single 7-leaf set at 6.0 m puts 0.51 m of stack on one side and every wind load through one lock stile, which is why the wind table in section 4 has a per-point column that falls as leaf count rises.
Stacking side, traffic leaf and open corners
Stacking side must be fixed before extrusion, because the head track, the sill and the locking stile are handed. A set delivered with the stack on the wrong side cannot be corrected on site.
Traffic leaf position is a handed decision too: it is normally the leaf adjacent to the stacking side, so that it swings clear of the stack.
Open corner posts remove one jamb entirely, which raises the clear opening to 100% but adds USD 120-260 per set and requires the post to be structurally restrained at both ends.
Odd leaf counts with a traffic leaf are the usual arrangement: 3, 5 or 7 leaves, of which one swings.
3. The Lintel Is the Product: Top-Hung Against Bottom-Rolling
A folding set is a hung system. Unlike a sliding door, where the weight goes into the sill and then into the floor, a top-hung folding set delivers its entire dead load into the lintel above the opening. The door manufacturer supplies a head profile; the building supplies the beam. The head profile is not the beam, and this is where folding door projects fail.
Deflection limit is L/500, not L/200
A window or a curtain wall is checked at L/200, or L/300 where the standard requires it. A folding head track has a stricter limit because the criterion is not appearance or glass contact: it is whether the hanger wheels stay engaged and whether the leaves still pass each other without binding. In practice the track is checked at L/500. For a 4.8 m span that is 9.6 mm of allowable deflection, against 24.0 mm at L/200.
Lintel sections: what passes and what does not
Lintel section
E (MPa)
I (mm⁴)
Mid-span deflection
Ratio
L/500 check
Door head profile 60x60x2.5 (6063-T6)
70000
3.17e+05
207.6 mm
L/23
FAIL
Steel RHS 100x50x3
210000
1.12e+06
19.6 mm
L/245
FAIL
Steel RHS 150x100x5
210000
7.54e+06
2.9 mm
L/1648
PASS
Steel RHS 200x100x6
210000
1.79e+07
1.2 mm
L/3919
PASS
Timber lintel 100×200 (C24)
11000
6.67e+07
6.3 mm
L/763
PASS
Reinforced concrete lintel 200×250
30000
2.6e+08
0.6 mm
L/8128
PASS
The load case is a 4.8 m opening with six Low-E leaves, 326.6 kg hung from the head, a uniform load of 667.5 N/m. Two results in that table decide most projects:
The door manufacturer head profile, 60 x 60 x 2.5 mm in 6063-T6, deflects 208 mm if it were to span alone. It is not a beam and it must be fixed to a stiff lintel at close centres.
A 100 x 50 x 3 mm steel lintel, a very common size for a masonry opening, deflects 19.6 mm and fails the L/500 check. The required steel second moment of area for this span and load is 2.3e+06 mm⁴, which means a 150 x 100 x 5 mm RHS or larger.
A lintel that was sized only for the masonry above it is a lintel that has never seen this load case. A 4.8 m folding set adds 326.6 kg hanging below the beam, on an eccentric line. The check has to be done by the project engineer against the actual lintel, and it is the first question to ask before quoting.
Required lintel inertia by opening and leaf count
Opening width
Leaves
Hung mass
Required I, steel (mm⁴)
Required I, timber (mm⁴)
3.0 m
3
204 kg
5.6e+05
1.1e+07
3.0 m
4
204 kg
5.6e+05
1.1e+07
3.0 m
5
203 kg
5.6e+05
1.1e+07
3.0 m
6
203 kg
5.5e+05
1.1e+07
3.6 m
3
246 kg
9.7e+05
1.8e+07
3.6 m
4
245 kg
9.7e+05
1.8e+07
3.6 m
5
244 kg
9.6e+05
1.8e+07
3.6 m
6
244 kg
9.6e+05
1.8e+07
3.6 m
7
243 kg
9.6e+05
1.8e+07
4.2 m
3
287 kg
1.5e+06
2.9e+07
4.2 m
4
286 kg
1.5e+06
2.9e+07
4.2 m
5
286 kg
1.5e+06
2.9e+07
4.2 m
6
285 kg
1.5e+06
2.9e+07
4.2 m
7
285 kg
1.5e+06
2.9e+07
4.8 m
3
328 kg
2.3e+06
4.4e+07
4.8 m
4
328 kg
2.3e+06
4.4e+07
4.8 m
5
327 kg
2.3e+06
4.4e+07
4.8 m
6
327 kg
2.3e+06
4.4e+07
4.8 m
7
326 kg
2.3e+06
4.4e+07
6.0 m
3
411 kg
4.5e+06
8.6e+07
6.0 m
4
410 kg
4.5e+06
8.6e+07
6.0 m
5
410 kg
4.5e+06
8.6e+07
6.0 m
6
409 kg
4.5e+06
8.6e+07
6.0 m
7
409 kg
4.5e+06
8.5e+07
Required inertia scales with the fourth power of the span, so a 6.0 m set needs roughly 2.4 times the steel of a 4.8 m set even though it is only 25% wider. This is the same rule that governs splitting a large opening: adding an intermediate support is far cheaper than buying the beam.
Head track fixings and the load path
Opening width
Leaves
Hung mass
Fixings at 400 mm
Load per fixing (x1.3 dynamic)
3.6 m
4
245 kg
10
313 N
3.6 m
5
244 kg
10
312 N
3.6 m
6
244 kg
10
311 N
3.6 m
7
243 kg
10
310 N
4.8 m
4
328 kg
12
348 N
4.8 m
5
327 kg
12
348 N
4.8 m
6
327 kg
12
347 N
4.8 m
7
326 kg
12
346 N
6.0 m
4
410 kg
16
327 N
6.0 m
5
410 kg
16
327 N
6.0 m
6
409 kg
16
326 N
6.0 m
7
409 kg
16
326 N
The fixing loads are modest; the failure is not fixing pull-out but the path behind it. The load hangs below the lintel centreline, so it applies torsion as well as vertical load. Chemical anchor pull-out, derived from bond stress with a conservative 2.0 MPa, is 6.3 kN for M10 x 100 mm and 8.3 kN for M12 x 110 mm – values that must be replaced by the anchor ETA for the actual substrate. Hollow block and aerated concrete are the two substrates where this changes the design.
Anchor
Pull-out at 2.0 MPa bond (kN)
Comment
M8 x 80 mm
4.0
Edge distances critical; rarely the governing check
M10 x 100 mm
6.3
Standard choice for head tracks
M12 x 110 mm
8.3
Used where the hung mass exceeds 350 kg
M16 x 125 mm
12.6
Corner posts and open corners
When bottom-rolling is the correct answer
Bottom-rolling folding sets carry the weight on a sill rail and use the head track only for guidance. The lintel problem disappears, and so does the structural engineering fee and the steel. The price is the threshold: a bottom rail needs 25-45 mm of height, which is above the French accessibility limit of 20 mm. Where a building has no accessible-route requirement, or where the opening is a retrofit and the lintel cannot be verified, bottom-rolling is usually the right decision. The porte coulissante article covers the same threshold-versus-watertightness conflict on sliding doors.
Decision
Top-hung
Bottom-rolling
Weight path
Into the lintel
Into the floor
Lintel check
Mandatory
Guidance only
Threshold achievable
0-5 mm flush, or 20 mm
25-45 mm
Accessibility (PMR 20 mm)
Achievable
Not achievable without a ramp
Floor requirement
None
Slab or beam under the sill; balcony edges need checking
Retrofit suitability
Only with a verified lintel
Generally suitable
Hardware cost index
100
85-95
Sill drainage
Track can be recessed
Rail must be drained or it holds water
4. Porte Pliante en Aluminium Hardware: Hangers, Wheels, Hinges and Locks
Folding hardware is the largest single cost line after the profiles, and it is where low-cost sets cut. Four checks cover almost everything: wheel contact stress, hinge grade on the traffic leaf, lock point count against wind load, and cycle duty class.
A top-hung leaf is carried by two carriages with two wheels each, so four wheels share the load. Contact pressure between a steel wheel and an aluminium track is a Hertzian line contact: a = sqrt(8FR / (pi b E*)) and p = 2F / (pi a b), with b the contact width, taken as 6 mm, and E* from the two elastic moduli. The yield strength of 6063-T6 is 170 MPa, so the comparison is direct.
Leaves
Leaf mass
Wheel
Load per wheel
Contact half-width a
Contact pressure p
Against 170 MPa
3
109 kg
28 mm steel
349 N
0.188 mm
196.8 MPa
FAIL
3
109 kg
40 mm steel
349 N
0.225 mm
164.7 MPa
PASS
3
109 kg
50 mm steel
349 N
0.251 mm
147.3 MPa
PASS
3
109 kg
34 mm POM
349 N
0.906 mm
40.9 MPa
PASS
4
82 kg
28 mm steel
261 N
0.163 mm
170.3 MPa
FAIL
4
82 kg
40 mm steel
261 N
0.195 mm
142.5 MPa
PASS
4
82 kg
50 mm steel
261 N
0.217 mm
127.5 MPa
PASS
4
82 kg
34 mm POM
261 N
0.784 mm
35.4 MPa
PASS
5
65 kg
28 mm steel
209 N
0.145 mm
152.2 MPa
PASS
5
65 kg
40 mm steel
209 N
0.174 mm
127.3 MPa
PASS
5
65 kg
50 mm steel
209 N
0.194 mm
113.9 MPa
PASS
5
65 kg
34 mm POM
209 N
0.701 mm
31.6 MPa
PASS
6
54 kg
28 mm steel
174 N
0.133 mm
138.8 MPa
PASS
6
54 kg
40 mm steel
174 N
0.159 mm
116.1 MPa
PASS
6
54 kg
50 mm steel
174 N
0.177 mm
103.9 MPa
PASS
6
54 kg
34 mm POM
174 N
0.639 mm
28.8 MPa
PASS
7
47 kg
28 mm steel
148 N
0.123 mm
128.4 MPa
PASS
7
47 kg
40 mm steel
148 N
0.147 mm
107.4 MPa
PASS
7
47 kg
50 mm steel
148 N
0.164 mm
96.1 MPa
PASS
7
47 kg
34 mm POM
148 N
0.591 mm
26.7 MPa
PASS
The pattern is that the wheel does not fail – the aluminium track does. A 28 mm steel wheel on a bare 6063-T6 track reaches 197 MPa with three leaves and 170 MPa with four, which is at or above yield, so the track takes a permanent groove over a season of use and the leaves start to drag. Two fixes are cheap: specify a 40 mm wheel (165 MPa for the three-leaf case) or a POM wheel (41 MPa), and on coastal jobs add a stainless track insert at USD 11-19/m of track. The third fix, moving to more leaves, is the one that actually solves it, because the load per wheel falls with leaf mass.
Hinges, EN 1935 grades and the traffic leaf
The hinged joints between leaves are not door hinges in the domestic sense. Each joint carries the leaf weight and the wind reaction, and the leaf-to-leaf joint is the part that shows wear first. Specify the hinge to EN 1935 with the grade matched to leaf mass, and note that the cycle count is the controlling parameter on a commercial terrace: a 48-cover brasserie cycles a set 80-160 times a day, or 29,000-58,000 times a year, which makes a 25,000-cycle hinge a component with a two-year life.
Duty
Cycles per day
Cycles per year
Hardware class to specify
Private terrace, 4-person household
6-12 / day
2,200-4,400
25,000
Private terrace, frequent entertaining
15-30 / day
5,500-11,000
50,000
Cafe / brasserie terrasse
80-160 / day
29,000-58,000
100,000
Hotel breakfast room / pool deck
40-90 / day
15,000-33,000
100,000
Showroom / event space
20-50 / day
7,000-18,000
50,000
Lock points: fewer leaves means more load per point
Wind on a folding set is collected by every leaf and delivered to the locking stile and the jamb, so the total force is the pressure times the whole opening area. What changes with leaf count is how many points share it: each meeting stile carries a top and bottom locking point, plus the traffic leaf lock.
Leaves
Design pressure
Total force on the set
Locking points
Load per point
2
0.8 kPa
8.8 kN
5
1766 N
2
1.2 kPa
13.2 kN
5
2650 N
2
2.0 kPa
22.1 kN
5
4416 N
4
0.8 kPa
8.8 kN
9
981 N
4
1.2 kPa
13.2 kN
9
1472 N
4
2.0 kPa
22.1 kN
9
2453 N
6
0.8 kPa
8.8 kN
13
679 N
6
1.2 kPa
13.2 kN
13
1019 N
6
2.0 kPa
22.1 kN
13
1698 N
At 2.0 kPa – a coastal or high-exposure elevation – a two-leaf set puts 4.4 kN on each locking point, well beyond the 1.5-2.5 kN that a standard espagnolette point is rated for. The same opening with six leaves puts 1.4 kN per point and is inside the normal range. This is the clearest engineering reason not to minimise leaf count on an exposed facade, and it runs against the U-value argument in section 5, which favours fewer leaves.
Hardware checklist for the purchase order
Wheel diameter and material, stated in millimetres and as steel or POM, with the track material stated separately.
Stainless track insert where the project is within 3 km of the coast or beside a pool.
Hinge grade to EN 1935 and the tested cycle class to EN 12400 / EN 1191.
Hardware for folding sets is covered by EN 1527; ask for the test report against that standard, not a general hardware catalogue sheet.
Locking points per meeting stile, and the per-point load the set is designed for.
Traffic leaf as a separate line item with its own hinge grade.
Two percent spare hardware kit: rollers, hinges, gaskets and one lock, shipped with the order.
5. Uw of a Folding Set: What the Leaf Count Costs
A folding door is thermally worse than a sliding door of the same opening, for one structural reason: the leaves have to close against each other, so the opening carries a full-height frame member at every leaf joint. Two adjacent stiles, each with its own thermal break, is a worse detail than a single frame-to-glass junction.
Leaf count against U-value, at three specifications
Leaves
Frame fraction
Uw, 34 mm break + Low-E
Uw, 34 mm break + triple
Uw, 20 mm break + Low-E
2
14.6%
1.36
1.04
1.48
3
16.7%
1.43
1.11
1.56
4
18.9%
1.49
1.18
1.64
5
21.1%
1.55
1.25
1.72
6
23.3%
1.62
1.33
1.8
7
25.5%
1.68
1.4
1.88
Two conclusions come out of the same table. First, the leaf-count penalty is real but bounded: 0.32 W/m²K between two leaves and seven, on the same 4.8 m opening. Second, that penalty is the same order as the penalty for dropping from a 34 mm break to a 20 mm break (0.26-0.30 W/m²K), so a specification that spends money on a wide break and then adds leaves to solve a handling problem is spending twice. The cheapest correction for a high leaf count is the glazing: triple glazing recovers 0.26-0.30 W/m²K across the whole range.
Thermal break width and glazing: where the value is
Break width (mm)
Frame Uf (W/m²K)
0
5.90
14
3.22
20
2.58
24
2.26
30
1.89
34
1.70
Uf follows a decaying exponential against break width: the first 14 mm buys 2.7 W/m²K, the step from 24 mm to 34 mm buys 0.55. The curve is the reason a 34 mm break is the export default and a 44 mm break is rarely worth it. Note that Uf is the frame value; the set value Uw is dominated by the glass area, which is why the glazing column in the table above moves Uw more per dollar than the break does. The fentre aluminium profile article derives the same relationship for aluminium windows and gives the fitted expression used here.
The meeting-stile linear transmittance penalty
Leaves
dUw at psi 0.04
dUw at psi 0.07
dUw at psi 0.10
dUw at psi 0.14
2
0.008
0.015
0.021
0.029
3
0.017
0.029
0.042
0.058
4
0.025
0.044
0.062
0.088
5
0.033
0.058
0.083
0.117
6
0.042
0.073
0.104
0.146
7
0.050
0.088
0.125
0.175
The joint term alone is small – 0.10 W/m²K at psi 0.10 with six leaves – which is the honest answer to anyone claiming the meeting stiles are the whole problem. The bigger thermal effect of leaf count is the frame area, not the psi value. What psi does control is the internal surface temperature at the stile, which is where condensation is first seen.
Condensation: check the stile, not the glass
In a heated room at 20 degrees C and 45% relative humidity the dew point is about 7.9 degrees C. A stile with a 34 mm break and a psi of 0.07 sits several degrees above that in a temperate winter, but a 20 mm break with psi 0.14 at 60% indoor humidity – a kitchen-diner, which is exactly where a terrace door is – can fall below it. The specification answer is not a wider break but a lower psi detail at the joint, a warm-edge spacer, and checking the internal surface temperature rather than the Uw number.
6. Threshold, Drainage and the 20 mm PMR Rule
Threshold height sets the watertightness class
Threshold detail
Height above finished floor
EN 12208 class typically achieved
Accessible route (PMR)
Notes
Flush, recessed track
0-5 mm
1A-2A
Yes
Needs a drained channel in front
Low threshold
15-20 mm
4A-5B
Yes, at 20 mm
The usual French residential detail
Standard bottom rail
25-45 mm
6A-8A
No
Ramp needed, or a top-hung detail instead
Rebated into the slab
0 mm with 30 mm rebate
3A-4A
Yes
Requires the slab to be set out for it
The trade is direct: every millimetre of threshold buys water performance and costs accessibility. French accessibility texts apply a ressaut limit of 20 mm, or 40 mm with a 1:2 chamfer, and a clear passage commonly taken as 900 mm. A bottom-rolling folding set at 25-45 mm therefore fails the accessible-route requirement unless the terrace is designed with a ramp, which is a landscape decision and not a door decision.
Terrace drainage arithmetic: capacity is never the problem, level is
A flush threshold only works if the water that lands on the terrace cannot reach it. The inflow is Q = A x r / 3600, with A in square metres and r in mm/h, giving litres per second. The drain capacity is an orifice calculation, Q = Cd x A x sqrt(2gh), with Cd taken as 0.62.
Terrace area
50 mm/h
75 mm/h
108 mm/h
150 mm/h
8 m2
0.11
0.17
0.24
0.33
12 m2
0.17
0.25
0.36
0.50
20 m2
0.28
0.42
0.60
0.83
30 m2
0.42
0.62
0.90
1.25
Terrace inflow in litres per second. A 12 m2 terrace in a 108 mm/h convective storm delivers 0.36 L/s.
Channel length
Grating width
Water head
Capacity at 25% open area
2.4 m
60 mm
5 mm
6.99 L/s
2.4 m
60 mm
10 mm
9.89 L/s
2.4 m
60 mm
20 mm
13.98 L/s
2.4 m
80 mm
5 mm
9.32 L/s
2.4 m
80 mm
10 mm
13.18 L/s
2.4 m
80 mm
20 mm
18.64 L/s
2.4 m
100 mm
5 mm
11.65 L/s
2.4 m
100 mm
10 mm
16.48 L/s
2.4 m
100 mm
20 mm
23.30 L/s
3.6 m
60 mm
5 mm
10.49 L/s
3.6 m
60 mm
10 mm
14.83 L/s
3.6 m
60 mm
20 mm
20.97 L/s
3.6 m
80 mm
5 mm
13.98 L/s
3.6 m
80 mm
10 mm
19.77 L/s
3.6 m
80 mm
20 mm
27.96 L/s
3.6 m
100 mm
5 mm
17.48 L/s
3.6 m
100 mm
10 mm
24.72 L/s
3.6 m
100 mm
20 mm
34.95 L/s
4.8 m
60 mm
5 mm
13.98 L/s
4.8 m
60 mm
10 mm
19.77 L/s
4.8 m
60 mm
20 mm
27.96 L/s
4.8 m
80 mm
5 mm
18.64 L/s
4.8 m
80 mm
10 mm
26.36 L/s
4.8 m
80 mm
20 mm
37.28 L/s
4.8 m
100 mm
5 mm
23.30 L/s
4.8 m
100 mm
10 mm
32.96 L/s
4.8 m
100 mm
20 mm
46.61 L/s
The smallest channel in the table, 2.4 m at 60 mm with 5 mm of head, passes 4.4 L/s against a terrace inflow of 0.36 L/s. Capacity is an order of magnitude above demand, so sizing the drain is not the engineering task. The task is the level: the grate must sit below the threshold, the terrace must fall away from the door at 1-2%, and the channel must have an access point for cleaning. A linear drain costs USD 30-62 per metre and is the cheapest item in the package – and the one whose absence is noticed in the first sustained rainfall.
Sealed joint length: why folding sets leak more than sliding doors
Watertightness depends on the total length of seal that has to stay compressed. A sliding door has the perimeter plus one meeting stile. A folding set has the perimeter plus two full-height seals at every leaf joint, and each of those joints moves every time the set is opened.
Leaves
Sealed length, folding
Sealed length, 2-leaf sliding
Ratio
2
18.8 m
19 m
1.00x
4
28.0 m
19 m
1.49x
6
37.2 m
19 m
1.98x
7
41.8 m
19 m
2.22x
A six-leaf set has 37.2 m of seal against 18.8 m for a two-leaf sliding door of the same opening, roughly double, and every moving joint is a compression seal that has to survive the cycle duty from section 4. This is the mechanical reason the service call rate on folding sets runs at 1.4-1.9 times a sliding door over the first 24 months.
7. Glazing, Safety and Acoustics
Glass build-ups and areal mass
Code
Build-up
Areal mass (kg/m2)
Ug (W/m2K)
When specified
F
6-16Ar-6, no coating
30.0
2.60
Interior or unheated enclosure only
D
6-16Ar-6 Low-E
30.0
1.10
Export default for heated buildings
T
6-12Ar-6-12Ar-6 Low-E
45.0
0.72
Cold climates and RE2020-driven projects
A
6-1.52PVB-6 / 16Ar / 6 Low-E
46.6
1.08
Road noise, or overhead-adjacent leaves
Glass mass is 2.5 kg/m² per millimetre of thickness, so the build-up is a direct input to the hanger load in section 4 and the lintel load in section 3. Upgrading from Low-E double to triple adds 15 kg/m², which on a 4.8 m six-leaf set is an extra 98 kg hanging from the head – a 30% increase in the load the lintel has to be checked for. This is the most common specification change that is made without rechecking the structure.
Glass thickness, wind span and human impact
Each leaf is a four-sided supported pane spanning between its own rails and stiles, so the span is the leaf glass width from section 2, not the opening width. Under EN 16612 the resistance is checked with the plate bending expression, and the stress varies with the square of the span, so halving the leaf width roughly quarters the stress. This is a second reason more leaves is the safer answer on an exposed elevation. Where a leaf is within reach of a floor level, or where the set gives access to a pool, the inner pane is specified as laminated and the leaves are toughened to EN 12150 with heat-soak testing to EN 14179; the spontaneous breakage rate of nickel sulphide inclusions is 0.1-0.2%, which on a 40-set project is a call-out every year or two.
Acoustics: the gap arithmetic
Leaves
Sealed length
Continuous gap
Gap as share of area
Rw from a 36 dB leaf
Rw from a 31 dB leaf
2
18.8 m
0.2 mm
0.034%
32.3 dB
29.5 dB
2
18.8 m
0.5 mm
0.085%
29.6 dB
27.8 dB
2
18.8 m
1.0 mm
0.170%
27.1 dB
26.0 dB
2
18.8 m
2.0 mm
0.341%
24.4 dB
23.8 dB
6
37.2 m
0.2 mm
0.067%
30.3 dB
28.3 dB
6
37.2 m
0.5 mm
0.168%
27.1 dB
26.1 dB
6
37.2 m
1.0 mm
0.337%
24.4 dB
23.8 dB
6
37.2 m
2.0 mm
0.674%
21.6 dB
21.2 dB
A gap is treated as an area with a transmission coefficient of 1, so the resulting Rw is -10 log of the area-weighted sum. A 1 mm continuous gap along 37.2 m of seal is 0.337% of the opening area and it takes a 36 dB leaf down to 24.4 dB. That is a 11.6 dB loss for a defect that is invisible from a metre away. It is also why acoustic performance on a folding set is a commissioning item, not a product item: the leaf build-up matters far less than whether the meeting stiles actually compress.
8. Profile, Alloy and Coating
Why folding doors are 6063 and not the stronger alloys
Alloy and temper
Rp0.2 (MPa)
Allowable stress, gammaM1 = 1.10 (MPa)
Typical extrusion pressure (MPa)
Used for folding sets
6060-T6
150
136
250-280
Yes, simple profiles
6063-T6
170
155
280-320
Yes, the export default
6061-T6
240
218
400-460
Rarely; pressure limit
6082-T6
260
236
420-480
Rarely; pressure limit
6005A-T6
215
195
380-420
Sometimes for heavily loaded stiles
The choice is not about strength. A folding leaf is deflection-controlled, not stress-controlled, and the stiles reach their L/200 or L/300 limit while the stress is still below 40% of allowable. The choice is about extrudability and surface quality. On a 152 mm billet, a 780 mm² folding profile has an extrusion ratio of about 23, and the press force is the extrusion pressure times the billet area: roughly 524 tonnes for 6063 against 815 tonnes for 6082. That difference removes roughly half the factories that can quote the profile, which shows up as price and as lead time rather than as a number on a datasheet.
T5 against T6 is the second decision. T5 is air-quenched and naturally aged, giving Rp0.2 of 110 MPa; T6 is water-quenched and artificially aged at 170-180 degrees C for 6-8 hours, giving 170 MPa. Because the leaf is deflection-controlled, T5 is sufficient for the frame; T6 is specified where the profile is loaded in bearing, which on a folding set means the hanger fixings and the hinge seats.
Wall thickness and the tolerance that actually matters
Element
Wall thickness (mm)
Why
Outer frame
1.8-2.0
Fixing pull-out and transport handling
Leaf stiles and rails
1.8-2.2
Hinge and hanger bearing, corner crimping
Meeting stiles
2.0-2.2
Locking point bearing and racking stiffness
Head track
2.5-3.0
Carries the set; fixings at 400 mm
Sill / bottom rail
2.5-3.0
Bottom-rolling: carries the set and foot traffic
The tolerance that causes field failures is not the profile outline, which is covered by EN 755-9 at +/- 0.15-0.35 mm. It is the knurling groove that grips the polyamide thermal break strip, held at +/- 0.05 mm. A groove worn 0.1 mm oversize by a tired tool does not bite, the composite shear strength falls, and the failure is delayed: the leaf drops over a heating season and then the lock will not engage. Ask for the shear test report by die batch, not by profile series.
Coating and corrosivity category
Standard / label
What it covers
Typical film or class
Where specified
Qualicoat Class 1
Powder coating, inland
60-80 microns
Standard inland orders
Qualicoat Class 2 (Seaside)
Powder coating, coastal
60-80 microns + pre-treatment
Within 3 km of coast or pool
Qualanod AA15 / AA20 / AA25
Anodising
15 / 20 / 25 microns
Architectural, high UV
AAMA 2604 / 2605
US performance spec
5 / 10 year Florida
North American projects
Qualideco
Sublimated wood effect
Over Qualicoat base
Residential, wood-look
ISO 9223 C2-C5-M
Corrosivity category
C2 inland to C5-M marine
Selecting the coating class
ISO 9227 neutral salt spray is a batch ranking test, not a life prediction: a 1,000 hour result compares two batches to each other and says nothing about a 20-year facade. On a folding set the corrosion risk is concentrated in the sill and the bottom of the meeting stiles, where water sits, and in the fasteners. A2-304 stainless is adequate inland; A4-316 is required in C4 and C5-M and beside pools. Brass and copper are anodic to aluminium and must not be used in contact with the frame, and wet concrete at pH 12-13 attacks aluminium directly, so the sill must be isolated from fresh mortar.
9. CE, DoP and What Each Certificate Does Not Cover
EN 14351-1, AVCP System 3 and the tested specimen
An external pedestrian door set without fire or smoke properties is covered by EN 14351-1 under AVCP System 3: the factory declares performance on the basis of initial type testing and factory production control, and issues a declaration of performance under CPR 305/2011. The declaration is only as good as the specimen that was tested, and this is where folding door documentation needs checking.
Ask for the tested specimen dimensions. A DoP based on a 2.4 m two-leaf set does not cover a 4.8 m six-leaf set; the classification does not extend by similarity in the way suppliers often imply.
Ask for the tested configuration: leaf count, glass build-up, threshold detail and the locking arrangement. Changing any of them invalidates the claim.
Ask whether the class reported for watertightness is the A series or the B series – see below.
Ask whether the declaration covers the set or only the profiles.
AEV classes and the A/B series trap
Property
Standard
Class meaning
Typical folding set
Air permeability
EN 12207
Class 0 (not tested) to 4
Class 2-3
Watertightness
EN 12208
A series 1A-9A, B series 1B-7B
4A-6A
Wind resistance
EN 12210
C1-C5 with deflection A/B/C
C3-C5
Operating effort
EN 12046-1
Measured force to move the leaf
Reported on request
Mechanical durability
EN 12400 / EN 1191
Cycle class
Must be stated on the order
EN 12208 has two series and the number does not carry across. Class 7A is 600 Pa; class 7B is 300 Pa, and 7B is the top of the unprotected series. A supplier quoting “class 7” has reported a protected test condition that the installed door may not reproduce. Always ask for the letter. The ventanas de aluminio article gives the same warning for aluminium windows and shows how EN 12208 and AAMA figures compare.
Burglar resistance: RC classes and the N suffix
Class
Attack tool and time
Feasible on a folding set
RC1N / RC1
Body force only, 0 / 3 min
Yes
RC2N / RC2
Screwdriver, pliers, wedge, 3 / 15 min
RC2 with laminated glass
RC3
Crowbar and second screwdriver, 20 min
Yes, with a full hardware package
RC4
Axe, hammer, chisel, cordless drill, 30 min
Rarely; cost is disproportionate
The N suffix means the glazing was not attack-tested. A folding set that is 76% glass and declared RC2N has no meaningful burglar rating, because the glass is the obvious route. The class is also a system property: the lock seats, the cylinder to EN 1303, the hinges to EN 1935, the glazing beads and the panel core all have to be rated, so changing the door leaf alone does not change the class. For folding sets the weak point is the meeting stile, and it needs a locking point top and bottom at every joint, not just at the traffic leaf. Hardware for folding sets is covered by EN 1527; ask for the test report against that standard.
10. Production Flow and the Inspection Points That Matter
Twelve steps and where the days go
Step
Days
Share of lead time
Note
Drawings and approval
5-7
18%
The only step the buyer can compress
Extrusion
3-5
11%
Die already exists for standard series
Thermal break assembly
2-3
7%
Knurling and crimping; see section 8
Cutting and machining
2-3
7%
Handing is fixed here
Surface treatment
2-3
7%
Pre-treatment quality governs coating life
Powder coating / anodising
2-3
7%
Batch colour consistency
Glazing unit production
3-5
11%
Often bought in
Assembly of leaves
2-3
7%
Corner crimping and sealing
Hardware fitting
1-2
4%
Hangers, hinges, locks
Pre-assembly test fold
1
4%
Highest value inspection step
Packing
1-2
4%
Crate engineering
Container loading
1-2
4%
See section 12
Total is 26-38 days against a quoted 30-45, and the buyer holds 18% of it. Approving drawings in 48 hours instead of seven days is the single largest saving available on the schedule, and it costs nothing.
Inspection points that catch the expensive errors
Dry-assemble one complete set at the factory and fold it. Photograph every configuration. This step catches more errors than all the others combined.
Check handing against the drawing: stacking side, traffic leaf side, opening direction.
Check the knurl shear report by die batch.
Check glass build-up against the leaf rebate depth – a 32 mm unit into a 28 mm rebate is the most common assembly error.
Run the set through a full open-and-close cycle with the hangers loaded and record the force.
Check the drainage path by pouring water, not by looking at it.
Check crate labelling against the packing list; sets are frequently split across crates.
The aluminium window supply article sets out the same inspection logic for aluminium windows, including the dry-assembly photograph step and why it outranks dimensional spot checks.
11. FOB Pricing by Configuration and Volume
Seven configurations at four order sizes
Configuration (FOB USD/m²)
30 m2 (1-2 sets)
100 m2
300 m2
800 m2
C1 2-panel, 20 mm break, float double
$148
$139
$130
$121
C2 3-panel, 24 mm break, Low-E
$177
$166
$156
$145
C3 4-panel, 30 mm break, Low-E
$193
$181
$170
$158
C4 5-panel, 34 mm break, Low-E
$211
$198
$186
$173
C5 6-panel, 34 mm break, Low-E, warm edge
$218
$205
$192
$179
C6 6-panel, 34 mm break, triple Low-E
$266
$250
$234
$218
C7 6-panel, 34 mm break, acoustic laminated
$252
$237
$222
$207
The spread between the cheapest and the dearest configuration is USD 104/m² at the 30 m² tier and USD 85/m² at 800 m², and almost all of it is glazing and break width rather than hardware. The leaf-count effect is smaller than most buyers expect: going from four to six leaves adds USD 13/m², which is less than the warm-edge spacer it is often traded against. What leaf count does change is the structural package – the lintel in section 3 is not in this price.
What the FOB price includes, and what it does not
Included in FOB
Not included
Profiles, thermal break, gaskets
Lintel, steel beam or structural works above the opening
Glazing units as specified
Installation labour and site equipment
Hangers, hinges, locks, handles
Crane or glass lifting equipment
Factory pre-assembly and test fold
Linear drain, terrace falls, landscaping
Export crating to the port
Freight, insurance, duty, anti-dumping duty
Standard documentation
Project calculations and engineered drawings – USD 8-18/m² below 150 m²
Spare hardware if ordered
Local certification or NF-type assessment
The most common false comparison in this product is between a Chinese FOB price and a European supply-and-install price. The European number normally includes the structural check, the project documentation and the installation. The FOB number includes none of them. The landed cost model in section 13 puts them on the same basis.
Options priced per square metre or per set
Option
Cost (USD/m² unless stated)
Qualicoat Class 2 (Seaside) powder
$8-14
Anodising Qualanod AA25 instead of powder
$18-30
A4-316 stainless fasteners and track insert
$9-16
Stainless steel running track insert
$11-19
Concealed multi-point locking on every meeting stile
$12-22
RC2 / RC3 hardware package
$26-55
Low threshold detail (recessed 5 mm + linear drain)
$30-62
Traffic leaf (porte de service) as 4th/5th panel
$45-95
Trickle / corner post (opening without a jamb)
$120-260
Acoustic laminated inner pane
$30-55
Triple glazing upgrade
$55-78
Integrated venetian blinds in the glazing cavity
$75-130
Curved / angled bay configuration
$90-165
Reduced stile sightline 35 mm (slim series)
$22-40
Steel-reinforced head beam
$12-26
Pre-assembled panel shipping (glass fitted)
$6-12
Spare hardware kit (2% of sets)
$4-9
Project documentation pack (DoP, calcs, drawings)
$8-18
Items marked as set-level pricing – the traffic leaf at USD 45-95 and the corner post at USD 120-260 – are the ones that most often appear as a variation order, because they are handed decisions that have to be made before extrusion. The door and window accessories article covers the hardware options for sliding and folding accessories in more detail, including roller and track specification.
12. MOQ, Lead Time, Payment, Packing and Warranty
Commercial terms
Term
Standard offer
Notes
MOQ
30 m² or 6 sets
Below this the die and set-up cost dominates
Lead time
30-45 days after drawing approval
Add 7-10 days for anodising
Payment
30% deposit, 70% before shipment
L/C at sight accepted above USD 50,000
Incoterms
FOB Shenzhen or Guangzhou (Nansha)
CIF available on request
Sample set
One set at 1.5x unit price
Credited against the first order above 100 m²
Packing
Plywood crate, leaves nested flat
Crate dimensions in the table below
Warranty
10 years coating, 5 years hardware
Excludes coastal sites without Class 2
Spare parts
2% hardware kit recommended
Rollers, hinges, gaskets, one lock
Documentation
DoP, test reports, drawings
Project calculation pack: USD 8-18/m²
Container loading: volume is the limit, not weight
Opening
Leaves
Crate (L x W x H)
Crate volume
Crate mass
Sets by volume
Sets by payload
Sets per 40HQ
Area per container
3.0 m
3
2.34 x 1.04 x 0.41 m
0.98 m3
249 kg
69
94
69 (volume)
478 m2
3.6 m
4
2.34 x 0.94 x 0.49 m
1.07 m3
290 kg
63
81
63 (volume)
524 m2
4.2 m
4
2.34 x 1.09 x 0.49 m
1.25 m3
331 kg
54
70
54 (volume)
527 m2
4.8 m
5
2.34 x 1.00 x 0.58 m
1.34 m3
372 kg
50
63
50 (volume)
559 m2
4.8 m
6
2.34 x 0.84 x 0.66 m
1.29 m3
372 kg
52
63
52 (volume)
580 m2
6.0 m
6
2.34 x 1.04 x 0.66 m
1.60 m3
454 kg
42
51
42 (volume)
585 m2
6.0 m
7
2.34 x 0.90 x 0.75 m
1.56 m3
454 kg
43
51
43 (volume)
601 m2
Folding sets are volume-limited on every configuration tested: a 40 ft high-cube takes 42-69 sets, using the whole 68 m³ of usable volume while using only 70-85% of the payload. That conclusion has a practical consequence, because a light-out, volume-out container is the ideal partner for a heavy cargo: sharing a container with tiles, stone or hardware can cut the freight allocation by 8-12%. Knock-down is not available for glazed folding leaves, so the levers are crate height, separator thickness and whether the glass is factory-fitted.
Below 8-10 m³ – roughly five sets – LCL freight runs at 3.0-3.5 times the per-unit cost of a full container. If the first order is small, either consolidate with another product from the same factory or accept that the freight is a sample cost, not a unit cost.
13. Landed Cost into the EU and the Anti-Dumping Lever
A worked model on a six-leaf set
Step
USD/m²
Note
FOB Shenzhen
$212
C5 configuration, 34 mm break, Low-E
Sea freight and insurance
$14.2
40HQ, volume-limited load
CIF European port
$226.2
Customs duty, 6%
$12.7
Classification-dependent
EU anti-dumping on aluminium extrusions
$47.1
Rate depends on the exporter
Landed at port
$286.0
Installation
$48
Crew of three, two sets per day
Installed total
$334.0
Against a European supply-and-install figure of USD 480/m² for an equivalent thermally broken aluminium folding set, the installed total of USD 334/m² is 30.4% lower. The saving is real but it is smaller than the FOB comparison suggests, and most of the difference between the two numbers is freight plus duty plus anti-dumping, which together add USD 74/m² – more than the entire difference between the cheapest and the most expensive configuration in section 11.
Sensitivity: the tariff lever is bigger than the product lever
Anti-dumping rate
Duty (USD/m²)
Landed
Installed
Saving vs local
0.0%
$0.0
$238.9
$286.9
40.2%
6.0%
$12.7
$251.6
$299.6
37.6%
12.1%
$25.7
$264.6
$312.6
34.9%
22.2%
$47.1
$286.0
$334.0
30.4%
32.1%
$68.1
$307.0
$355.0
26.0%
The anti-dumping line moves the installed price by roughly USD 65/m² across its plausible range. That is larger than the difference between any two configurations in section 11, and roughly four times the sea freight. The practical rule is the same one that applies to aluminium windows and verandas: settle the customs classification and the exporter rate first, because it moves the price more than any product decision, and then optimise the product. The double glazed windows article reaches the same conclusion for aluminium windows into the EU.
14. Installation Sequence and Commissioning
Nine steps, in order
Verify the lintel before anything is unpacked: section capacity, deflection class and the fixing substrate. Record it.
Set the head track on a continuous packing line and shim to the lintel at 400 mm centres; the track must not be used to pull a wavy lintel straight.
Fix the jambs and the sill, checking diagonal and level; dry-fit the frame without glass first.
Hang the leaves from the stacking side outwards, two people per leaf up to 80 kg, four beyond that.
Fit the hinge joints between leaves and set the leaf-to-leaf gap before tightening.
Set the locking points and the keeps; each stile must compress evenly top and bottom.
Fit gaskets, then the drainage channel and the external flashing or membrane terminations.
Glaze if the leaves were shipped unglazed, using setting blocks and not gluing the unit to the frame.
Commission: cycle the set five times under load, record the operating force, pour water on the threshold and watch where it goes.
Commissioning checks that predict the first year
Check
Method
Pass criterion
Track deflection
Straightedge along the track with the set hung
No gap over 1 mm/m
Leaf-to-leaf gap
Feeler gauge at three heights
Even within 1 mm top to bottom
Operating force
Spring balance at the handle, EN 12046-1
Within the declared class
Lock engagement
Cycle and check each point
Every point carries load, none free
Threshold drainage
Pour water on the terrace side
Water leaves; no standing water at the track
Seal continuity
Paper test: pull a strip through each seal
Resistance at every point
Cycle test
Five full cycles loaded
No binding, no drift in leaf alignment
The paper test on the seals is the cheapest acoustic and air-tightness check available and it takes two minutes per set. Section 7 shows what a 1 mm gap costs: 11.6 dB.
15. Failure Modes: Which Ones Are Bought, Not Installed
Six failure modes and where they are decided
Failure
Symptom
Root cause
Decided at
Leaves dragging after one season
Increasing operating force, then binding
28 mm steel wheel on a bare aluminium track, contact pressure above yield
Specification
Leaf drop at the lock
Lock will not engage after a heating season
Knurl groove oversize, composite shear strength loss
Die batch
Head track sagging
Visible gap at the head, leaves jump
Lintel not checked; 100 x 50 x 3 gives 19.6 mm on 4.8 m
Design
Water at the threshold
Staining inside after sustained rain
Level, not capacity: no drain, or terrace falls toward the door
Design
Glass upgrade without a structural recheck
Track deflection after a triple-glazing change
+15 kg/m² on the hung load
Variation order
Corrosion at the sill
Filiform corrosion under the coating, seized rollers
A2 fasteners in C4-C5-M, or wet concrete contact
Specification
Four of the six are decided before the set is manufactured. That is the pattern across all wide-opening products: the expensive failures are specification errors, and installation errors are the cheaper ones to fix.
What to put in the purchase order
Wheel diameter and material, and the track material, stated separately.
Lintel capacity confirmed in writing by the project engineer, with the deflection class named.
Threshold height, drainage provision and the finished floor levels on the drawings.
Coating class and fastener grade matched to the ISO 9223 category of the site.
Cycle class of the hardware for the actual duty from section 4.
Handing: stacking side and traffic leaf side, confirmed on the approved drawing.
A clause covering structural re-verification if the glazing build-up is changed after approval.
16. Two Delivered Projects
Bordeaux brasserie terrace: eight top-hung sets
Item
Value
Sets / opening
8 sets, 4.2 x 2.3 m, 5 leaves, top-hung
Total glazed area
77.3 m²
Configuration
34 mm break, 6-16Ar-6 Low-E, warm edge, traffic leaf
Structure
Existing steel lintel verified and upgraded to 150 x 100 x 5 RHS
Threshold
20 mm low threshold with a 100 mm linear drain outside
Coating
Qualicoat Class 2, A4-316 fasteners, site 12 km from the coast
FOB
$214/m²
CIF
$228.2/m²
Duty 6% + anti-dumping 22.2%
$12.8 + $47.5/m²
Landed
$288.5/m²
Installed
$336.5/m²
Local equivalent
$480/m² installed
Saving
29.9%, USD 11,086
18-month record
3 service calls (2 lock adjustments, 1 roller), no water ingress
The linear drain was USD 42/m and USD 1,344 in total, the smallest line in the package. It is also the reason the 20 mm threshold has no water complaints across two winters. The lintel upgrade was the largest single non-door cost and it was identified before the order, which is the only way it stays cheap.
Lyon residential retrofit: six bottom-rolling sets
Item
Value
Sets / opening
6 sets, 3.0 x 2.3 m, 4 leaves, bottom-rolling
Total glazed area
41.4 m²
Configuration
30 mm break, 6-16Ar-6 Low-E, 25 mm bottom rail
Structure
Existing concrete lintel not verifiable; load taken on the slab instead
Why bottom-rolling
Avoided structural engineering at USD 1,400-2,600 per opening
Threshold
25 mm, private house with no accessible-route requirement
FOB
$196/m²
CIF
$210.2/m²
Duty 6% + anti-dumping 22.2%
$11.8 + $43.5/m²
Landed
$265.5/m²
Installed
$313.5/m²
Local equivalent
$445/m² installed
Saving
29.6%, USD 5,445
18-month record
2 service calls, both sand in one bottom rail
The decision in this project was structural, not product-led. Bottom-rolling cost 6% less in hardware and removed a lintel verification that would have consumed most of the saving. The price was a 25 mm threshold, acceptable here because the house has no accessibility obligation; on a project with an accessible route the same opening would have needed a top-hung set and the structural works that come with it.
17. Porte Accordon Against Porte Coulissante, Galandage and Porte-Fenetre
Ten rows that matter
Property
Porte accordon (folding)
Porte coulissante (sliding)
Porte a galandage
Porte-fenetre
Clear opening of the structural bay
88-96%
50-67% (2-panel) / 67-75% (3-rail)
92-95% (pocket)
100% (no fixed panel)
Frame area fraction (4.8 m opening)
18-23%
12-16%
14-18%
10-14%
Uw, 34 mm break + Low-E
1.48-1.62
1.35-1.48
1.40-1.55
1.30-1.45
Air permeability, EN 12207
Class 2-3
Class 3-4
Class 2-3
Class 3-4
Watertightness, EN 12208
4A-6A
6A-8A
3A-5A
7A-8A
Sealed joint length (4.8 x 2.3 m)
37-49 m
19-24 m
24-30 m
15-19 m
Threshold height available
0-20 mm (top-hung) / 25-45 mm (bottom-rolling)
20-45 mm
0-5 mm
15-25 mm
Structural demand above the opening
Lintel sized for the hung load
None (weight on sill)
Pocket wall must be built
None
Hardware count per bay
4-10 hangers + 2-6 hinges per leaf
4-8 rollers
2-4 rollers
3 hinges
Service call rate, first 24 months
1.4-1.9x a sliding door
Baseline 1.0x
1.2-1.5x
0.7-0.9x
FOB index (per m2)
118-155
100
150-190
85-110
What the table actually decides
Most of these rows are noise once four questions are answered. Read the table only against these:
Is there a verifiable lintel, or a budget to create one? If not, folding top-hung is off the list – take bottom-rolling or sliding.
Is an accessible route required through the opening? If yes, the threshold row decides it: folding top-hung at 0-20 mm, or galandage, and bottom-rolling folding is out.
Is the opening cycled more than about 30 times a day? If yes, the service call row and the hardware cycle row dominate every thermal row in the table.
Is the opening above roughly 6 m, or is it a corner? If yes, two sets or a corner post is the decision, and leaf count is secondary.