Blog

Home   >   Sliding Doors   >   Porte Coulissante Wholesale in China: Porte Coulissante en Aluminium, Porte Automatique Coulissante, Baie Vitre Coulissante et Prix FOB

Porte Coulissante Wholesale in China: Porte Coulissante en Aluminium, Porte Automatique Coulissante, Baie Vitre Coulissante et Prix FOB

Porte coulissante en aluminium on a residential terrace in China - two-panel sliding door with slim thermal break frames, low PMR threshold and a linear drain channel
Two-panel aluminium porte coulissante on a timber terrace – slim thermal break frames, 20 mm PMR threshold and a linear caniveau set in front of the sill.
A porte coulissante is not a glazed frame that happens to slide. It is four interfaces at once: a rolling interface, a water interface at the terrace, an access interface at the threshold, and – when it is a porte automatique coulissante – a safety interface with sensors and a duty cycle. Every field problem we see on a porte coulissante comes from one of those four, and almost never from the glass. This page gives the numbers behind each of them: clear opening as a function of panel count and track count, panel mass against the handling crew you can actually get on site, the 2 690 mm container height that caps panel height at roughly 2 540 mm, Uw from 1.10 to 3.62 W/m2K computed with EN ISO 10077-1 on a 2 400 x 2 300 reference door, the 20 mm PMR threshold against a blocked terrace drain, operator force from 123 to 435 N, and FOB pricing from 108 to 312 USD/m2 with the option adders that actually move a quote.
FOB / m2
108 – 312 USD
Uw range
1.10 – 3.62
Panel mass
68 – 200 kg
MOQ
40 m2
Lead time
28 – 35 d
Sommaire / Contents
1. Why a Porte Coulissante Is a Building Interface
2. Panel Count, Tracks and Clear Opening
3. Baie Vitre Coulissante: Size Limits Set by Site Access
4. Porte Coulissante en Aluminium: Alloys and Coating
5. Uw for a Sliding Door (EN ISO 10077-1)
6. Seuil, Terrace Water and the PMR 20 mm Rule
7. Air, Water, Wind: AEV Classes and What They Cover
8. Porte Automatique Coulissante: Operator Sizing
9. Locking, RC Grades and Cylinders
10. Portes Pliantes vs Porte Coulissante
11. Fabrication Sequence and Lead Time
12. FOB Pricing
13. MOQ, Lead Time, Payment, Packing
14. Landed Cost
15. Installation Sequence and Failure Modes
16. Project Cases
17. Material Comparison and What It Decides
18. RFQ Checklist
19. Glossary and Standards Index

Why a Porte Coulissante Is a Building Interface

The four interfaces that decide whether the door works

Specify a porte coulissante as a glazed panel and you will buy a panel. Specify it as an interface and you buy a system that survives its first winter. The four interfaces are:

What this page gives you

Every table below is computed from the parameters stated next to it, so you can reproduce the numbers with your own geometry. Where a number depends on a test result rather than a formula (AEV classes, Acotherm, RC grades) the table states what the test does and does not cover, because those are the two places where a porte coulissante specification usually goes wrong.

Two failure patterns account for most service calls on a porte coulissante in France and Spain: water at the sill after a blocked terrace drain, and a leaf that has gone heavy because the glass was upgraded without re-specifying the carriages. Both are decided at order time, not on site.

For the sliding-window version of the same engineering – per-wheel Hertz contact stress against an aluminium rail, drain slot capacity against a 2 L/min/m2 spray rate – see fentres coulissantes en aluminium. For the Spanish market equivalent with CTE DB-HE1 limits, see ventanas de aluminio y cristal.

Panel Count, Tracks and Clear Opening

Clear opening is a ratio, not a dimension

The first question on a porte coulissante is how much of the structural opening you actually get to walk through. It is a function of how many panels the unit has and how many of them can stack in one direction. A two-panel unit on one track gives you 50 per cent. Nothing about the frame changes that. The table below is the arithmetic for a 2 400 mm opening; the ratio column is what you should argue about with the architect, because the ratio is fixed long before the millimetres are.

Config Panels Tracks Arrangement Clear opening
C1 2 1 1 vantail fixe + 1 coulissant 50.0 %
C2 3 2 1 fixe lateral + 2 coulissants 66.7 %
C3 4 2 2 fixes lateraux + 2 coulissants centraux 50.0 %
C4 4 4 4 vantaux empilables d un cote 75.0 %
C5 6 3 3 fixes + 3 coulissants 50.0 %
C6 6 6 6 vantaux empilables d un cote 83.3 %
C7 2 2 2 vantaux a galandage (poches) 92.0 %
C8 3 3 angle rencontre, ouverture d angle 100.0 %

Panel width and clear opening for four structural widths

Config Opening W (mm) Panel width (mm) Clear opening (mm) Ratio
C1 2400 1200 1200 50.0 %
C1 3600 1800 1800 50.0 %
C1 4800 2400 2400 50.0 %
C1 6000 3000 3000 50.0 %
C2 2400 800 1601 66.7 %
C2 3600 1200 2401 66.7 %
C2 4800 1600 3202 66.7 %
C2 6000 2000 4002 66.7 %
C3 2400 600 1200 50.0 %
C3 3600 900 1800 50.0 %
C3 4800 1200 2400 50.0 %
C3 6000 1500 3000 50.0 %
C4 2400 600 1800 75.0 %
C4 3600 900 2700 75.0 %
C4 4800 1200 3600 75.0 %
C4 6000 1500 4500 75.0 %
C5 2400 400 1200 50.0 %
C5 3600 600 1800 50.0 %
C5 4800 800 2400 50.0 %
C5 6000 1000 3000 50.0 %
C6 2400 400 1999 83.3 %
C6 3600 600 2999 83.3 %
C6 4800 800 3998 83.3 %
C6 6000 1000 4998 83.3 %
C7 2400 1200 2208 92.0 %
C7 3600 1800 3312 92.0 %
C7 4800 2400 4416 92.0 %
C7 6000 3000 5520 92.0 %
C8 2400 800 2400 100.0 %
C8 3600 1200 3600 100.0 %
C8 4800 1600 4800 100.0 %
C8 6000 2000 6000 100.0 %

Two things fall out of the table. First, going from C3 (four panels, two tracks) to C4 (four panels, four tracks) costs one extra track and buys 25 percentage points of clear opening – that is the cheapest opening-width upgrade available. Second, C7 (galandage, panels slide into a pocket in the wall) reaches 92 per cent but moves four decisions into the shell package: the pocket has to be built before the door is measured, the pocket interior is outside the thermal envelope, only the head of the pocket is serviceable, and the pocket mouth is a single-line seal that caps water tightness around 5A.

Where each configuration belongs

Baie Vitre Coulissante: Size Limits Set by Site Access

Panel mass against the crew you can actually get

A baie vitre coulissante is sized by the factory up to about 3 200 x 3 000 mm. It is sized on site by something much smaller: the number of glaziers who can legally lift the panel and the route they have to carry it along. The table below uses a 100 mm sash sightline, 3.9 kg/m of profile and 4.5 kg of hardware per leaf. Note what happens between the standard float double glazing and the acoustic laminate: the panel grows by 30 to 50 kg, which is the difference between a two-person carry and a trolley.

Panel Glazing Glass area (m2) Mass (kg) Weight (N) Handling
P-01 1000 x 2150 5-16Ar-5 Low-E 1.56 68.1 668 2 handlers + suction cups
P-01 1000 x 2150 6-16Ar-44.2 acoustic 1.56 86.8 851 see crew table
P-02 1200 x 2300 5-16Ar-5 Low-E 2.10 84.3 827 4 handlers + suction cups
P-02 1200 x 2300 6-16Ar-44.2 acoustic 2.10 109.5 1074 see crew table
P-03 1500 x 2400 5-16Ar-5 Low-E 2.86 106.4 1044 4 handlers + suction cups
P-03 1500 x 2400 6-16Ar-44.2 acoustic 2.86 140.7 1381 see crew table
P-04 1800 x 2500 5-16Ar-5 Low-E 3.68 130.0 1276 4 handlers + suction cups
P-04 1800 x 2500 6-16Ar-44.2 acoustic 3.68 174.2 1709 see crew table
P-05 2000 x 2600 5-16Ar-5 Low-E 4.32 148.4 1456 4 handlers + suction cups
P-05 2000 x 2600 6-16Ar-44.2 acoustic 4.32 200.2 1964 see crew table

Handling column is computed for the Low-E build-up: up to 80 kg is two handlers with suction cups, up to 160 kg is four handlers, up to 260 kg needs a glazing trolley or mini-crane, and above that you need a lift plan. The acoustic build-up pushes P-04 and P-05 out of the four-handler range entirely.

The access route table

Ask for this table before you fix the panel size, not after. It is the cheapest constraint to design around and the most expensive to discover on delivery day.

Route Max panel (mm) Max mass (kg) What actually limits it
Escalier, palier a 90 deg, 900 mm wide 1900 x 900 80 panel must turn on the landing; diagonal rules the plan
Ascenseur 8 personnes 1000 x 1250 x 2200 mm 2100 x 1400 160 panel travels tilted; door opening 800 mm is the real gate
Monte-charge 1600 x 2400 mm 2600 x 1800 250 booking window and loading dock height decide the day
Grue / robot de vitrage exterieur 3200 x 2800 450 no route limit, but needs a road closure or a mast climber

Container height caps panel height at about 2 540 mm

A standard 40 ft high-cube container has an internal height of 2 690 mm. A sliding panel travels standing up in an A-frame crate, and you need roughly 150 mm of timber and handling clearance under and around it. That puts the practical maximum panel height inside a standard container at about 2540 mm. Above that the door has to ship open-top or on a flat rack, which adds 1,200 – 2,400 USD per container and restricts the carriers that will take it.

Panel Crate height (mm) Fits 40HQ Shipping mode
P-01 1000 x 2150 2300 yes 40HQ standard
P-02 1200 x 2300 2450 yes 40HQ standard
P-03 1500 x 2400 2550 yes 40HQ standard
P-04 1800 x 2500 2650 yes 40HQ standard
P-05 2000 x 2600 2750 no open top / flat rack
P-05 at 2 600 mm does not fit a standard 40HQ. If the design needs that height, decide it at quotation stage: the surcharge is a container-level cost, so on a single-unit order it can exceed the value of the door. Splitting the opening into two stacked units with a fixed transom is almost always the cheaper answer.

For the glazing engineering behind the acoustic build-ups used above, see double glazed windows and soundproof windows.

Porte Coulissante en Aluminium: Alloys, Sections and Coating

Alloy selection and allowable stress

Door profiles are almost always 6060 or 6063, and the reason is not strength. A 2 500 mm door leaf is controlled by deflection and by hardware pull-out, not by yielding, so the extra strength of 6061 or 6082 buys nothing that a door needs – while the higher extrusion pressure roughly halves the number of presses that can produce the profile. The table gives EN 755-2 characteristic values and the allowable stress with a partial factor of 1.10 per EN 1999-1-1.

Alloy-temper Rp0.2 (MPa) Rm (MPa) Allowable (MPa) Press force Note
6060-T66 150 195 136 x0.95 thin-wall, best surface, sash-friendly
6063-T5 110 175 100 x1.00 air quench, standard for frames
6063-T6 170 215 155 x1.00 water quench + age, corners and lock seats
6061-T6 240 290 218 x1.62 high strength, needs 60-75 % more press force
6082-T6 260 310 236 x1.70 structural, limited extrusion envelope

Wall thickness and where it matters

Coating specification by exposure

Powder coating and anodising are specified by exposure class, not by colour. The thickness numbers below are the ones to write into the order; the salt-spray hours are a batch ranking tool, not a service-life prediction.

Standard Film / layer Test reference Where it is used
Qualicoat Class 1 60 – 80 um 1,000 h standard inland
Qualicoat Class 2 Seaside 60 – 80 um 2,000 h coastal < 3 km
Qualanod AA15 10 um sealed interior / mild
Qualanod AA20 15 um sealed standard facade
Qualanod AA25 20 um sealed coastal and pool
AAMA 2604 50 um 5 yr Florida North America mid
AAMA 2605 60 um 10 yr Florida North America coastal
PVDF 70 % 35 – 45 um 10 yr Florida high UV, desert
ISO 9227 salt spray ranks batches against each other. It does not predict how long a coating lasts on a building. If you need a service-life statement, use the exposure class in ISO 12944-6 (C2 to C5-M) and the corresponding Qualicoat or Qualanod class, and write both into the order.

Colour is a thermal decision on a door as much as an aesthetic one. A dark frame on a south-facing porte coulissante reaches 70 – 80 deg C in summer, which is close to the softening range of a PVC thermal break. PA66 GF25 polyamide is the default for that reason; see fentre aluminium profile systems for the Uf curve and the strip width trade-off.

Uw for a Sliding Door (EN ISO 10077-1)

Reference geometry

All the Uw numbers below use EN ISO 10077-1 on a two-panel reference door of 2400 x 2300 mm: glass area Ag = 4.20 m2, frame area Af = 1.32 m2, glazing perimeter lg = 12.4 m, interlock junction li = 2.3 m. Glass covers 76.1 % of the opening, which is lower than a window because a door has a taller interlock and a deeper bottom rail.

The Uw matrix: strip width x glazing x spacer

Glazing Strip Aluminium spacer Stainless spacer TPS warm edge
4-16Ar-4 float 0 mm 3.62 3.58 3.54
4-16Ar-4 float 14 mm 2.98 2.94 2.90
4-16Ar-4 float 20 mm 2.82 2.78 2.74
4-16Ar-4 float 24 mm 2.75 2.70 2.66
4-16Ar-4 float 30 mm 2.66 2.62 2.58
4-16Ar-4 float 34 mm 2.61 2.57 2.53
5-16Ar-5 Low-E 0 mm 2.45 2.40 2.36
5-16Ar-5 Low-E 14 mm 1.81 1.76 1.72
5-16Ar-5 Low-E 20 mm 1.65 1.61 1.57
5-16Ar-5 Low-E 24 mm 1.57 1.53 1.49
5-16Ar-5 Low-E 30 mm 1.49 1.44 1.40
5-16Ar-5 Low-E 34 mm 1.44 1.40 1.36
4-16Ar-4-16Ar-4 Low-E 0 mm 2.19 2.15 2.11
4-16Ar-4-16Ar-4 Low-E 14 mm 1.55 1.51 1.47
4-16Ar-4-16Ar-4 Low-E 20 mm 1.39 1.35 1.31
4-16Ar-4-16Ar-4 Low-E 24 mm 1.31 1.27 1.23
4-16Ar-4-16Ar-4 Low-E 30 mm 1.23 1.19 1.15
4-16Ar-4-16Ar-4 Low-E 34 mm 1.18 1.14 1.10

Read the matrix by rows and by columns. Down a column (strip 0 -> 34 mm, glazing held constant) the Uw falls by about 1.2 to 1.5. Across a row (float -> Low-E -> triple, strip held constant) it falls by about 1.5 to 2.0. So on a door, as on a window, the glazing is worth more than the frame – and it costs less: 12 – 18 USD/m2 for Low-E against 24 – 58 USD/m2 to widen the frame from 20 to 34 mm. Buy the glass first.

Warm edge: what you are actually buying

Strip Glazing Aluminium spacer TPS warm edge Delta Uw
14 mm 4-16Ar-4 float 2.98 2.90 0.081
14 mm 5-16Ar-5 Low-E 1.81 1.72 0.081
14 mm 4-16Ar-4-16Ar-4 Low-E 1.55 1.47 0.081
24 mm 4-16Ar-4 float 2.75 2.66 0.081
24 mm 5-16Ar-5 Low-E 1.57 1.49 0.081
24 mm 4-16Ar-4-16Ar-4 Low-E 1.31 1.23 0.081
34 mm 4-16Ar-4 float 2.61 2.53 0.081
34 mm 5-16Ar-5 Low-E 1.44 1.36 0.081
34 mm 4-16Ar-4-16Ar-4 Low-E 1.18 1.10 0.081

A warm edge spacer moves Uw by 0.05 to 0.09 on this door. That is poor value as a U-value purchase. What it does buy is edge temperature: roughly 3 to 5 K warmer at the glass edge, which is where condensation starts. On a porte coulissante the bottom rail and the interlock are the cold surfaces that generate complaints, so the warm edge belongs in a condensation specification, not in an energy specification.

Regulatory targets the door has to meet

Programme / zone Uw limit (W/m2K) Note
France RE2020 / RT2012 renovation (CEE BAR-EN-105) 1.30 Uw <= 1.3 for the grant
France RE2020 new build, maison individuelle 1.50 Uw <= 1.5 typical door target
Spain CTE DB-HE1 2019 zone D / E 1.80 Uw <= 1.8
Spain CTE DB-HE1 2019 zone alpha / A 3.20 Uw <= 3.2 for the loosest zone
Passive house component (PHI) 0.80 Uw <= 0.80 with installed Psi
The 1.3 W/m2K figure attached to French renovation grants is a common trap. It is the threshold for the CEE BAR-EN-105 energy-saving certificate, not a universal French requirement. A door that reaches 1.3 qualifies for the grant; a door at 1.5 does not, but it can still be code-compliant. Write the actual target into the order, not “RE2020”.

Seuil, Terrace Water and the PMR 20 mm Rule

Threshold height against water tightness class

The threshold (seuil) is where the water and the accessibility rule meet head-on. Raise it and you keep water out; raise it and you create a step. The table is the practical mapping between upstand height and the EN 12208 class a porte coulissante can realistically achieve, with the exposure each one is good for.

Upstand EN 12208 Threshold type Suitable exposure
0 mm 1A – 2A seuil encastre, PMR total interior only or fully roofed > 1.5 m
5 mm 2A – 3B seuil plat 5 mm roofed terrace, linear drain in front
15 mm 4B – 6A seuil 15 mm + relevage standard exposed residential
20 mm 5B – 7A seuil PMR 20 mm PMR compliant exposed residential
25 mm 6A – 8A seuil 25 mm + caniveau coastal / zone 3-4
45 mm 8A – 9A seuil 45 mm + relevage very exposed, drain behind

The 20 mm PMR threshold has no margin against a blocked drain

Run the arithmetic. A 12 m2 terrace in front of the door, at a design rainfall intensity of 108 mm/h (the figure used for exposed French coastal sites), delivers 21.6 L/min of water to the terrace surface. If the terrace is built level instead of falling away, and the linear drain is blocked, that water stands on the slab. The depth is simply the rainfall depth:

Rain duration Standing depth Overtops 20 mm seuil Overtops 45 mm seuil
5 min 9.0 mm no no
10 min 18.0 mm no no
20 min 36.0 mm yes no
30 min 54.0 mm yes yes
60 min 108.0 mm yes yes
Twenty minutes of design rain puts 36 mm of water on a level terrace. A 20 mm PMR threshold is overtopped. This is not a product defect – it is a drained-area detail. The three fixes are, in order of cost: build a 1 – 2 per cent fall away from the facade; size the linear drain for the terrace area rather than for the door width; and add a roofed reveal of at least 300 mm. Only the third one costs real money, and it is the one that also protects the glass and the coating.

Linear drain sizing

A caniveau in front of the sill is cheap and it is the element everybody undersizes. Grating inlet capacity by orifice flow (discharge coefficient 0.62, 25 per cent open area, 2.4 m length) at three water depths:

Drain width At 5 mm head At 10 mm head At 20 mm head
80 mm 9.3 L/s 13.2 L/s 18.6 L/s
100 mm 11.7 L/s 16.5 L/s 23.3 L/s
150 mm 17.5 L/s 24.7 L/s 35.0 L/s
200 mm 23.3 L/s 33.0 L/s 46.6 L/s

At 10 mm of head even an 80 mm drain passes 13 L/s, which is far more than the 0.36 L/s the terrace delivers. Capacity is never the problem; level is. The drain has to sit lower than the threshold upstand, the grate has to be removable without lifting the leaf, and the outlet has to be accessible from the terrace rather than from inside the wall. Specify those three and the width is secondary.

Capillary break under the leaf

Gap under the leaf / at the joint Capillary rise h = 2 sigma / (rho g d)
1.5 mm 9.9 mm
2 mm 7.4 mm
3 mm 4.9 mm
4 mm 3.7 mm
5 mm 3.0 mm
6 mm 2.5 mm
8 mm 1.9 mm
10 mm 1.5 mm

Water climbs a narrow gap by surface tension. A 3 mm gap under the leaf lifts water 4.9 mm, which matters next to a 5 mm flush threshold and is irrelevant next to a 20 mm one. It is still worth writing a capillary break into the sill detail: a drip notch on the underside of the leaf, a drained cavity under the sill pan, and an EPDM or silicone interface that is not continuous with the interior floor build-up. Without the break, a flush threshold will wick even with no standing water at all.

Sill pan and the French installation context

Air, Water, Wind: AEV Classes and What They Cover

Air permeability and water tightness

EN 12207 class Pressure band at which the limit is met
Class 0 < 600 Pa, no requirement
Class 1 150 – 600 Pa
Class 2 300 – 600 Pa
Class 3 600 – 1050 Pa
Class 4 >= 1050 Pa

Water tightness has two series and the difference is the single most common mis-specification in the door market. The A series is tested with the specimen protected; the B series is tested unprotected. A supplier quoting 7A is quoting a protected result.

A series (protected) Pressure B series (unprotected) Pressure
1A 0 Pa 1B 0 Pa
2A 50 Pa 2B 50 Pa
3A 100 Pa 3B 100 Pa
4A 150 Pa 4B 150 Pa
5A 200 Pa 5B 200 Pa
6A 250 Pa 6B 250 Pa
7A 300 Pa 7B 300 Pa
8A 450 Pa Pa
9A 600 Pa Pa
7B is 300 Pa and it is the ceiling of the unprotected series – there is no 8B or 9B. If a quote says “Class 7” without the letter, it is meaningless: 7A is 600 Pa and 7B is 300 Pa, and on an exposed west-facing terrace the number that applies is the B one.

Wind resistance and French wind zones

EN 12210 class Test pressure band
C1 400 – 800 Pa
C2 800 – 1200 Pa
C3 1200 – 1600 Pa
C4 1600 – 2000 Pa
C5 >= 2000 Pa
French wind zone Characteristic pressure Pa Typical situation
Zone 1 0.32 kN/m2 320 Pa plaine, interieur
Zone 2 0.39 kN/m2 390 Pa littoral interieur, altitude 250 m
Zone 3 0.47 kN/m2 470 Pa littoral < 10 km
Zone 4 0.56 kN/m2 560 Pa littoral expose, Corse

The EN 12210 class also carries a deflection sub-class: A is L/150, B is L/200, C is L/300. On a sliding door the deflection that matters is not the one in the standard – it is the interlock engagement. Two leaves have to stay meshed by at least 8 – 12 mm through the whole load cycle; once the interlock opens past that, the seal line is gone and the AEV result on the certificate stops describing the door you bought.

Certification: what each document proves

For the sliding-window side-by-side of these classes and the trap in each one, see fentres coulissantes en aluminium. For the Spanish AEV equivalents under CTE, see ventanas de aluminio y cristal.

Porte Automatique Coulissante: Operator Sizing and Safety

Force, power and what actually sizes the operator

A porte automatique coulissante is sized by four resistances that add together: rolling resistance of the carriages, seal drag, friction added by wind pressing the leaf against its guides, and the inertia of accelerating the leaf. With a rolling coefficient of 0.03, seal drag of 40 N, acceleration of 0.40 m/s2 and a nominal leaf speed of 0.40 m/s, the required operator force and mechanical power are:

Leaf mass Wind pressure Required force Mechanical power at 0.40 m/s
120 kg 0 Pa 123 N 49 W
120 kg 200 Pa 140 N 56 W
120 kg 500 Pa 165 N 66 W
120 kg 1000 Pa 206 N 82 W
180 kg 0 Pa 165 N 66 W
180 kg 200 Pa 182 N 73 W
180 kg 500 Pa 206 N 83 W
180 kg 1000 Pa 248 N 99 W
250 kg 0 Pa 214 N 85 W
250 kg 200 Pa 230 N 92 W
250 kg 500 Pa 255 N 102 W
250 kg 1000 Pa 296 N 119 W
350 kg 0 Pa 283 N 113 W
350 kg 200 Pa 300 N 120 W
350 kg 500 Pa 324 N 130 W
350 kg 1000 Pa 366 N 146 W
450 kg 0 Pa 352 N 141 W
450 kg 200 Pa 369 N 148 W
450 kg 500 Pa 394 N 158 W
450 kg 1000 Pa 435 N 174 W

The numbers are small – 49 to 174 W of mechanical power – and that is the point. On a sliding door the operator is never sized by the weight alone. It is sized by the duty cycle and by the environment. A 250 kg leaf on a shop entrance needs a bigger drive than a 450 kg leaf in a house, and the reason is cycles per day, not kilograms.

Duty cycle classes

Application Cycles per day Rated life (cycles) Leaf speed Typical build
Residential, 1 – 2 occupants 10 – 30 0.5 M 0.3 – 0.5 m/s belt drive, IP54, no heating
Small office / clinic 100 – 300 1 M 0.4 – 0.6 m/s belt drive, IP54, radar + presence
Retail entrance 600 – 1,500 3 M 0.5 – 0.7 m/s belt or rack, IP54, double radar
Supermarket / station 2,000 – 5,000 5 M 0.6 – 0.8 m/s rack drive, IP65, redundant controller
Airport / hospital corridor 8,000 – 15,000 10 M 0.7 – 1.0 m/s linear drive, IP65, hot standby
A cycle is one open plus one close. Residential use is 10 – 30 cycles per day; a retail entrance is 600 – 1,500. Putting a residential operator on a retail door is the single most common automation failure, and it shows up as a controller fault at roughly month nine. Size on cycles, then check the mass.

Safety standards and the force limits that matter

Reference Scope What it requires of the installation
EN 16005 Powered pedestrian doorsets – safety in use presence detection on the secondary closing edge, kinetic energy and force limits, escape route behaviour
EN 12453 Powered gates and doors – safety in use 400 N sustained, 1,400 N peak dynamic, 150 N residual after reversal
EN 12635 Installation and use commissioning record, logbook, maintenance intervals
EN 60335-2-103 Particular requirements for drives for gates, doors and windows electrical safety of the drive unit
IP rating IEC 60529 IP54 minimum outdoors, IP65 where the operator sits in the splash zone

The EN 12453 force limits are the ones to write into the commissioning record, because they are measurable on site with a force gauge: 400 N sustained, 1,400 N peak dynamic, 150 N residual after reversal, measured at 50, 300, 500, 1,200 and 1,800 mm above floor level. On a door that is also an escape route, EN 16005 governs the behaviour in use: presence detection on the secondary closing edge, force and kinetic-energy limits, and defined behaviour on power failure. If your fire strategy relies on the door, a break-out kit is not optional.

Exterior environment for the operator

Locking, RC Grades and Cylinders

Multi-point locking and anti-lift

A sliding leaf locks at the interlock, not at the frame. The lock has to pull the two leaves together, resist the leaf being lifted out of its track, and resist the interlock being levered apart. In practice that means:

RC grades and the N suffix

EN 1627 grade Attack tools Glass Typical use
RC1N opportunist, 50 N tools no glass attack test shed, garage
RC2N screwdriver, pliers, wedge no glass attack test N variant: glass not tested
RC2 as RC2N + glass attack 3 min glass included standard residential
RC3 crowbar + second screwdriver, 5 min glass included insurer default in FR/ES
RC4 axe, chisel, hammer, drill, 10 min glass included high value, jewellery
The N suffix means the glazing was not attack-tested. On a porte coulissante, which is 76 per cent glass, an RC2N certificate describes a door whose weakest element has not been tested at all. If you need a security grade, specify the non-N variant with a laminated build-up and confirm the grade applies to the tested glazing.

The grade is produced by five components together – lock seats, cylinder, hinges or carriages, glazing beads and panel core. Replacing the leaf does not upgrade the grade. French and Spanish insurers commonly require RC3, and retrofitting RC2 to RC3 after handover costs close to the price of a new door.

Portes Pliantes vs Porte Coulissante

The numbers side by side

Attribute Portes pliantes (bifold) Porte coulissante inline Coulissant a levage
Clear opening 90 – 95 % 50 – 75 % 92 – 100 %
Panel width 700 – 900 mm 1000 – 2000 mm 1000 – 1800 mm
Air permeability Class 3 – 4 Class 2 – 3 Class 3 – 4
Water tightness 5A – 7A 3A – 5A 6A – 8A
Moving parts per m2 high (hinges + pivots) low (carriages) medium
Threshold 20 – 45 mm, continuous 0 – 45 mm 20 – 25 mm + drain
Cost index 130 – 165 100 190 – 240
Service call rate 1.4 – 1.8 x sliding 1.0 1.6 – 2.0 x sliding
Best for wide opening, sheltered sheltered to moderate, big glass exposed, high performance

Portes pliantes win on clear opening and on air permeability, because each leaf is hung and compressed rather than sliding on a brush seal. They lose on moving parts, on service calls, and on cost. A bifold set has a hinge or pivot per leaf plus a carrier per leaf; a sliding unit has two or four carriages total, regardless of how many panels it has.

What the comparison actually decides

Full bifold engineering including panel-count arithmetic and U-values is in aluminum bifold and accordion systems and accordion door systems.

Fabrication Sequence and Lead Time

Where the days go

A made-to-order porte coulissante takes 28 production days plus 7 days of buyer-controlled time, so 35 days from deposit to container. The buyer-controlled block is the drawing approval loop, and it is the only part of the schedule that a buyer can compress.

Operation Days Share What happens
Decoupe et usinage des profils 4 11.4 % CNC, percages drainage, fraisage seuil
Sertissage barrette polyamide 3 8.6 % rainurage, sertissage, echantillon cisaillement
Assemblage dormants et ouvrants 3 8.6 % sertissage mecanique, equerres, collage
Pose joints, brosses et seuil PMR 2 5.7 % EPDM, brosse polypropylene, seuil 20 mm
Traitement de surface 2 5.7 % degraissage, conversion zirconium-titane
Pulverisation poudre / anodisation 3 8.6 % 60-80 um, etuvage 190-200 C
Vitrage et scellement IGU 2 5.7 % intercalaire, argon, scellement secondaire
Montage galets et reglage 2 5.7 % chariots, rail inox, reglage hauteur et aplomb
Motorisation (si porte automatique) 3 8.6 % cable, capteurs, EN 16005 reglages
Controle dimensionnel et essais 2 5.7 % jeux, EN 12046-1 effort, cycle moteur
Emballage et mise en caisse 2 5.7 % cornieres, film, caisse contreplaquee

Drawing approval is 20.0 % of the total. Everything else is machine time that cannot be reduced by asking. If the programme is tight, the lever is returning the approved shop drawing in 24 hours rather than seven days, and freezing the glazing and hardware schedule before the profile is cut.

Inspection points worth paying for

  1. Composite shear test on the thermal break, reported by die batch. A knurl seat worn 0.1 mm over size drops the shear strength and the symptom is a dropped leaf one season later.
  2. A dry-build of one unit of every configuration, photographed. This single step catches more errors than all the other inspections combined – most commonly a 32 mm glazing unit ordered into a 28 mm rebate.
  3. EN 12046-1 operating force measurement. If the leaf needs more than the specified force, the carriage or the rail is wrong, and no amount of site adjustment will fix it.
  4. Drain path check with water on the dry-built unit, not a visual check. The water has to exit at the weep slots, not into the sill cavity.
  5. Glazing: EN 1279 dew point, EN 12150 fragment count on tempered panes, and EN 14179 heat-soak certificates where they were specified. Nickel sulphide inclusions break about 1 pane in 500 to 1,000; heat soak costs 4 – 7 USD/m2 and removes the risk.
  6. Coating: film thickness to the specified class, cross-cut adhesion (ISO 2409), and a colour delta check against the approved panel. For anodising, sealing quality.
  7. For a porte automatique coulissante: a 50-cycle run-in with the force profile recorded, plus the EN 12453 force measurements at the five heights.
  8. Packing: A-frame restraint, corner protection, and a crate height that matches the container you are actually booking.

FOB Pricing

Configuration matrix

Configuration (2 400 x 2 300 reference) 60 m2 200 m2 600 m2 1500 m2
C1 inline, 20 mm strip, float DGU 118 142 124 108
C2 inline, 24 mm strip, Low-E DGU 142 172 150 132
C3 a levage, 24 mm strip, Low-E 186 224 196 172
C4 a levage, 34 mm strip, Low-E + warm edge 218 262 232 206
C5 a levage, 34 mm strip, triple Low-E 268 312 282 250

The 118 to 268 USD/m2 spread is driven by three things: the strip width, the glazing, and whether the door is inline or a levage. Going from C2 to C3 – the same frame, the lift-and-slide mechanism instead of a brush seal – is about 30 per cent. Going from C4 to C5 – Low-E double to Low-E triple – is about 22 per cent for roughly 0.4 of Uw.

Option adders

Option Adder (USD/m2 unless stated)
Warm edge TPS spacer 6 – 9
Laminated inner pane 44.2 11 – 16
Acoustic asymmetric 6-16Ar-44.2 18 – 26
Stainless rail insert on bottom track 7 – 11
Twin-wheel tandem carriage 14 – 22
Concealed inox roller carriage 12 – 18
Automatic operator + radar + presence 420 – 980 /leaf
Automatic operator, IP65 rack drive, MCBF 5 M 1,150 – 2,400 /leaf
Break-out kit for escape route 180 – 340 /leaf
Seuil PMR 20 mm with capillary break 22 – 38 /m
Linear caniveau 100 mm + grate 30 – 55 /m
Galandage pocket cassette 85 – 140 /leaf
Pleated retractable moustiquaire 38 – 62 /m2
Sliding screen panel on inner track 45 – 78 /m2
Motorised lift-and-slide drive 260 – 420 /leaf
RAL 7016 / custom powder (Qualicoat Class 1) 4 – 8
Qualicoat Class 2 Seaside / Qualanod AA25 9 – 15
NF CSTB + CEKAL dossier (per project) 1,400 – 3,600 /project
Acotherm AC1-AC4 registration 900 – 2,400 /project
Heat-soak test EN 14179 4 – 7
Crate engineering for panels > 2 500 mm 12 – 20
Open-top / flat-rack surcharge (per container) 1,200 – 2,400
Certification dossiers, wind-load calculations and heat-soak testing are per-project costs. They do not fall with volume. On an order under 150 m2 they add 8 – 18 USD/m2. A European quotation often includes them and a Chinese FOB quotation usually does not – which is the most common reason two quotes look further apart than they are.

MOQ, Lead Time, Payment, Packing

Commercial terms

Container loading

In a 40 ft high cube (68 m3 usable, 22 t payload) a crated 2 400 x 2 300 unit gives:

Metric Value
Units by volume 37 units
Units by weight 123 units
Controlling limit volume
Glazed area per container 204 m2
Volume utilisation 97.9 %
Payload utilisation 29.9 %

The consignment is volume-limited and uses only 30 % of the payload. That has two consequences. Knock-down packing does not help – a sliding door has no volume to save, the glass cannot be nested and the panels are already flat. And the consignment is an ideal partner for a heavy product in a shared container: pairing with stone, tiles or a glass balustrade lifts container utilisation by 8 – 12 per cent. Below about 8 – 10 m3, LCL is the right answer; above it, wait for a full container – five units shipped LCL cost 3.0 – 3.5 times more per unit than 37 units in a 40HQ.

Landed Cost

A worked import model

Step USD/m2
FOB Shenzhen / Foshan (C3 configuration, 200 m2 tier) 186.0
Ocean freight + THC (40HQ, 204 m2) 15.2
Marine insurance (0.6 % of CIF) 1.2
CIF European port 202.4
Customs duty (6 % – verify the HS code) 12.1
Anti-dumping on Chinese aluminium extrusions (22.2 %) 44.9
Landed, before installation 259.5
Installation and sealing 48.0
Delivered and installed 307.5
Local European equivalent 372.0

That is 307.5 against 372.0 for a locally sourced equivalent, a saving of 17.3 %. Note where the money goes: freight is 15.2 USD/m2, about 8 per cent of FOB. Duty plus anti-dumping is 57.0 USD/m2, about 28 per cent of FOB.

Sensitivity: the tariff line is bigger than the product

Customs duty Cost
0 % 0.0 USD/m2
6 % 12.1 USD/m2
15 % 30.4 USD/m2
25 % 50.6 USD/m2
Anti-dumping rate Cost
0.0 % 0.0 USD/m2
8.0 % 16.2 USD/m2
22.2 % 44.9 USD/m2
32.1 % 65.0 USD/m2
The anti-dumping swing from 0 to 32.1 per cent is 65.0 USD/m2, which is larger than the entire price difference between configuration C1 and C5, and four times the ocean freight. For any European project, settle the tariff classification and the current anti-dumping measure before you optimise the product specification. Confirm the HS code and the TARIC measure with your broker in writing.

Installation Sequence and Failure Modes

Eight steps

  1. Check the structural opening against the shop drawing on all four dimension bases. Confirm the finished floor level at the threshold: the 20 mm PMR dimension is measured from the finished floor, not from the slab.
  2. Set the sill. Bed it on a continuous non-shrink mortar or a proprietary sill support, never on packers alone. Fit the sill pan and the capillary break before the frame goes in.
  3. Fit the outer frame. Shim at fixing points only, never at mid-span; pack behind the fixing lugs and do not distort the profile. Fixings must not pass through the thermal break.
  4. Level the bottom rail to 1 mm/m. This is the single setting that decides how the door feels for the next twenty years; a rail out of level makes every other adjustment a compromise.
  5. Install the linear drain in front of the sill, at a level below the threshold upstand, with the outlet accessible from the terrace. Test it with a bucket before the terrace is finished.
  6. Hang the leaves, fit the anti-lift blocks, and set the carriage height so that the interlock engages by at least 12 mm over the full travel.
  7. Glaze. Set blocks under the glass, never let the pane sit on the frame, and leave the specified edge clearance so the panel can drain.
  8. Seal and commission. Outer seal is vapour-open tape; the sill gets a membrane turned up at the ends. Silicone alone at the sill is the most common leak. For a porte automatique coulissante, run the force profile and record the EN 12453 measurements at all five heights.

Six failure modes, four of them decided at order time

Project Cases

Montpellier, 34 units, residential terraces

A 34-unit development 4 km from the coast, wind zone 3 (0.47 kN/m2), every unit with a 2 400 x 2 300 two-panel porte coulissante onto a terrace. Configuration C4: 34 mm strip, Low-E double glazing with a warm edge, levage mechanism, 20 mm PMR threshold with a capillary break, and a 100 mm caniveau in front of every sill. Qualicoat Class 2 Seaside with A4 stainless fixings because the site is inside the 3 km coastal band.

Nantes, 12 units, renovation with accessibility retrofit

A 1970s block converted to accessible apartments. The constraint was not thermal – it was the 20 mm PMR threshold on terraces that were built level and drained only by a single point gully. Configuration C3, 24 mm strip, Low-E double glazing, inline mechanism, 20 mm threshold, and a new 150 mm linear drain across the full width of each terrace tied into the existing gully.

Material Comparison and What It Decides

Aluminium, uPVC, timber and steel-clad

Attribute Aluminium (thermal break) uPVC Timber / alu-clad Steel
Uw achievable on a 2.4 x 2.3 door 1.10 – 1.80 1.20 – 1.70 1.00 – 1.40 1.60 – 2.40
Max leaf height 2 600 – 3 000 mm 2 200 – 2 400 mm 2 300 – 2 500 mm 2 600 – 3 200 mm
Sightline at the interlock 40 – 60 mm 90 – 120 mm 80 – 100 mm 35 – 50 mm
Coastal 3 km durability good with Class 2 / AA25 good, UV-sensitive high maintenance poor unless galvanised + coated
Fire performance non-combustible melts, smoke combustible non-combustible
Maintenance cycle 10 yr coating check 10 yr gasket / hardware 2 – 4 yr refinish 5 yr coating check
Recycled content 60 – 80 % typical low renewable high
FOB index 100 70 – 85 140 – 190 120 – 160

What the comparison actually decides

Do not read the Uw row first. On a porte coulissante the material choice is decided by four questions, and if any one of them is answered the wrong way the material is forced:

Aluminium is the wrong answer when the opening is small and sheltered and the budget is the binding constraint, when the frame will sit in contact with wet concrete or CCA-treated timber without a separation layer, or when the site uses sulphur fumigation that will attack the anodic layer. In those cases say so at quotation stage rather than discovering it in year three.

RFQ Checklist

Eight technical items

  1. Structural opening on all four dimension bases, plus the finished floor level at the threshold and the terrace finish level.
  2. Configuration: number of panels, number of tracks, stacking direction, and whether it is inline, a levage or a galandage.
  3. Wind zone and the design pressure in Pa, with the height and terrain coefficients. Not “wind zone 3” – the number.
  4. Glazing build-up including spacer type, gas fill, coating, and whether heat soak and lamination are required.
  5. Threshold height required by the accessibility rule that applies (20 mm PMR in France, 13 mm at 1:2 under ADA 404.2.5, 5 mm under AS 1428.1), plus the drained area in front of it.
  6. AEV performance required, with the A or B series stated for water.
  7. For a porte automatique coulissante: cycles per day, required opening width on escape, power supply, IP rating, and whether break-out is required.
  8. Coating class and colour, with the distance to the sea and the pool.

Eight commercial items

  1. Quantity in square metres and in units, per configuration.
  2. Target FOB port and Incoterms version.
  3. Whether the quote includes certification dossiers, wind calculations and heat soak, or whether they are priced separately.
  4. Spare parts allowance (2 per cent of carriages and gaskets is standard).
  5. Packing standard and whether panels over 2 500 mm are included, with the open-top surcharge stated if they are.
  6. Payment terms and whether an LC is required.
  7. Warranty in years per component, and the coastal exclusion in writing.
  8. Lead time measured from which event – deposit, or approved drawing.

If you are comparing this against a broader supplier shortlist, the evaluation method in how to evaluate a China supplier and Foshan doors and windows suppliers covers the factory-audit side. For window packages ordered with the doors, see aluminium windows and doors and windows and doors wholesale.

Glossary and Standards Index

French – English product terms

French English Why it matters
porte coulissante sliding door the product; “coulissant” alone can mean a window
vantail / ouvrant leaf / sash panel count is quoted in vantaux
dormant outer frame the part fixed into the opening
seuil threshold / sill where water and accessibility meet
seuil PMR 20 mm 20 mm accessible threshold French accessibility limit
caniveau linear drain / channel drain the cheapest item that prevents most leaks
rail bottom track the load path; level it to 1 mm/m
galet / chariot roller / carriage the wearing part; re-specify when glass changes
crémone / condamnation lock / locking on a slider it locks at the interlock
barrette thermal break strip PA66 GF25, 14 – 34 mm
meneau / traverse mullion / transom adding one halves the span
baie vitrée glazed bay / large glazed opening the wide-opening variant
porte automatique coulissante automatic sliding door adds EN 16005 and a duty cycle
portes pliantes folding / bifold doors the alternative when opening width wins
à galandage pocket / slide-away 92 % clear opening, four shell-package conditions
a levage lift-and-slide compresses a gasket instead of dragging a brush
prise de cotes site measuring four dimension bases, or a 40 – 60 mm error
pose en applique / tunnel / feuillure three installation positions per DTU 36.5; the AEV claim depends on it

Standards referenced on this page

Reference Subject
EN 14351-1 Doors and windows – product standard, AVCP System 3 for standard doors
EN ISO 10077-1 Thermal transmittance calculation – frame, glazing and linear losses
EN ISO 13788 Internal surface temperature and the fRsi condensation criterion
EN 12207 Air permeability, classes 0 – 4
EN 12208 Water tightness, A series (protected) and B series (unprotected), 7B = 300 Pa ceiling
EN 12210 Wind resistance, classes C1 – C5 with deflection sub-class A/B/C
EN 12046-1 Operating force measurement
EN 755-2 Mechanical properties of extruded aluminium alloys
EN 1999-1-1 Design of aluminium structures, partial factor 1.10
EN 12020-1 / -2 Tolerances for precision profiles
EN 16005 Powered pedestrian doorsets – safety in use
EN 12453 Powered doors and gates – force limits 400 / 1 400 / 150 N
EN 12635 Installation and use of powered doors – commissioning and logbook
EN 1627 Burglar resistance grades RC1N – RC6, N = glazing not tested
EN 1303 Cylinder requirements and durability grades
EN 1279 Insulating glass units – dew point and gas leakage
EN 12150 / EN 12600 / EN 14179 Tempered glass, impact classification, heat soak
EN 673 Determination of the U value of glazing
Qualicoat / Qualanod / AAMA 2603-2605 Coating specifications by exposure class
ISO 12944-6 / ISO 9227 Corrosivity classes; salt spray as a batch ranking tool
DTU 36.5 French installation of windows and doors
CEE BAR-EN-105 French energy-saving certificate operation, Uw 1.3 for grant eligibility

Related reading on this site

[footer_contact_form]