Home > Sliding Doors > Porte Coulissante Wholesale in China: Porte Coulissante en Aluminium, Porte Automatique Coulissante, Baie Vitre Coulissante et Prix FOB
Porte Coulissante Wholesale in China: Porte Coulissante en Aluminium, Porte Automatique Coulissante, Baie Vitre Coulissante et Prix FOB
Two-panel aluminium porte coulissante on a timber terrace – slim thermal break frames, 20 mm PMR threshold and a linear caniveau set in front of the sill.
A porte coulissante is not a glazed frame that happens to slide. It is four interfaces at once: a rolling interface, a water interface at the terrace, an access interface at the threshold, and – when it is a porte automatique coulissante – a safety interface with sensors and a duty cycle. Every field problem we see on a porte coulissante comes from one of those four, and almost never from the glass. This page gives the numbers behind each of them: clear opening as a function of panel count and track count, panel mass against the handling crew you can actually get on site, the 2 690 mm container height that caps panel height at roughly 2 540 mm, Uw from 1.10 to 3.62 W/m2K computed with EN ISO 10077-1 on a 2 400 x 2 300 reference door, the 20 mm PMR threshold against a blocked terrace drain, operator force from 123 to 435 N, and FOB pricing from 108 to 312 USD/m2 with the option adders that actually move a quote.
The four interfaces that decide whether the door works
Specify a porte coulissante as a glazed panel and you will buy a panel. Specify it as an interface and you buy a system that survives its first winter. The four interfaces are:
Rolling interface – the leaf weight travels through two or four carriages onto a bottom rail. The rail, not the wheel, is the part that wears, and the wheel specification has to be re-checked every time the glass specification changes.
Water interface – the sill sits between a wet terrace and a dry floor. The threshold upstand, the linear drain in front of it, and the sill pan under it form one chain. The chain is only as good as its lowest element, which is usually the drain.
Access interface – the same threshold is a step. French PMR rules cap it at 20 mm (or 40 mm with a 1:2 chamfer), which is a hard number that competes directly with the water interface. This is the one place where a regulation and a physics requirement fight.
Safety interface – on a porte automatique coulissante the operator, the sensors and the escape-route behaviour are regulated (EN 16005, EN 12453) and the drive has a cycle rating. A residential operator fitted to a retail entrance fails inside a year.
What this page gives you
Every table below is computed from the parameters stated next to it, so you can reproduce the numbers with your own geometry. Where a number depends on a test result rather than a formula (AEV classes, Acotherm, RC grades) the table states what the test does and does not cover, because those are the two places where a porte coulissante specification usually goes wrong.
Two failure patterns account for most service calls on a porte coulissante in France and Spain: water at the sill after a blocked terrace drain, and a leaf that has gone heavy because the glass was upgraded without re-specifying the carriages. Both are decided at order time, not on site.
For the sliding-window version of the same engineering – per-wheel Hertz contact stress against an aluminium rail, drain slot capacity against a 2 L/min/m2 spray rate – see fentres coulissantes en aluminium. For the Spanish market equivalent with CTE DB-HE1 limits, see ventanas de aluminio y cristal.
Panel Count, Tracks and Clear Opening
Clear opening is a ratio, not a dimension
The first question on a porte coulissante is how much of the structural opening you actually get to walk through. It is a function of how many panels the unit has and how many of them can stack in one direction. A two-panel unit on one track gives you 50 per cent. Nothing about the frame changes that. The table below is the arithmetic for a 2 400 mm opening; the ratio column is what you should argue about with the architect, because the ratio is fixed long before the millimetres are.
Config
Panels
Tracks
Arrangement
Clear opening
C1
2
1
1 vantail fixe + 1 coulissant
50.0 %
C2
3
2
1 fixe lateral + 2 coulissants
66.7 %
C3
4
2
2 fixes lateraux + 2 coulissants centraux
50.0 %
C4
4
4
4 vantaux empilables d un cote
75.0 %
C5
6
3
3 fixes + 3 coulissants
50.0 %
C6
6
6
6 vantaux empilables d un cote
83.3 %
C7
2
2
2 vantaux a galandage (poches)
92.0 %
C8
3
3
angle rencontre, ouverture d angle
100.0 %
Panel width and clear opening for four structural widths
Config
Opening W (mm)
Panel width (mm)
Clear opening (mm)
Ratio
C1
2400
1200
1200
50.0 %
C1
3600
1800
1800
50.0 %
C1
4800
2400
2400
50.0 %
C1
6000
3000
3000
50.0 %
C2
2400
800
1601
66.7 %
C2
3600
1200
2401
66.7 %
C2
4800
1600
3202
66.7 %
C2
6000
2000
4002
66.7 %
C3
2400
600
1200
50.0 %
C3
3600
900
1800
50.0 %
C3
4800
1200
2400
50.0 %
C3
6000
1500
3000
50.0 %
C4
2400
600
1800
75.0 %
C4
3600
900
2700
75.0 %
C4
4800
1200
3600
75.0 %
C4
6000
1500
4500
75.0 %
C5
2400
400
1200
50.0 %
C5
3600
600
1800
50.0 %
C5
4800
800
2400
50.0 %
C5
6000
1000
3000
50.0 %
C6
2400
400
1999
83.3 %
C6
3600
600
2999
83.3 %
C6
4800
800
3998
83.3 %
C6
6000
1000
4998
83.3 %
C7
2400
1200
2208
92.0 %
C7
3600
1800
3312
92.0 %
C7
4800
2400
4416
92.0 %
C7
6000
3000
5520
92.0 %
C8
2400
800
2400
100.0 %
C8
3600
1200
3600
100.0 %
C8
4800
1600
4800
100.0 %
C8
6000
2000
6000
100.0 %
Two things fall out of the table. First, going from C3 (four panels, two tracks) to C4 (four panels, four tracks) costs one extra track and buys 25 percentage points of clear opening – that is the cheapest opening-width upgrade available. Second, C7 (galandage, panels slide into a pocket in the wall) reaches 92 per cent but moves four decisions into the shell package: the pocket has to be built before the door is measured, the pocket interior is outside the thermal envelope, only the head of the pocket is serviceable, and the pocket mouth is a single-line seal that caps water tightness around 5A.
Where each configuration belongs
C1 / C5 – sheltered openings, budget-driven housing, and anywhere the wall either side of the opening carries services or structure.
C2 / C6 – the stacking configurations. C6 gives 83 per cent clear opening and is the right answer for a wide opening onto a terrace where the wall to one side is free.
C4 – four panels on four tracks, 75 per cent. The usual choice for a 4 800 mm opening in a villa living room.
C7 galandage – maximum opening, minimum visible frame. Specify it only when the pocket is detailed by the architect and the thermal line is drawn through the pocket, not through the door.
C8 angle rencontre – a corner opening with no post. Structurally it moves the whole corner load into the head, so the header deflection check governs; see heavy duty aluminium sliding doors.
Baie Vitre Coulissante: Size Limits Set by Site Access
Panel mass against the crew you can actually get
A baie vitre coulissante is sized by the factory up to about 3 200 x 3 000 mm. It is sized on site by something much smaller: the number of glaziers who can legally lift the panel and the route they have to carry it along. The table below uses a 100 mm sash sightline, 3.9 kg/m of profile and 4.5 kg of hardware per leaf. Note what happens between the standard float double glazing and the acoustic laminate: the panel grows by 30 to 50 kg, which is the difference between a two-person carry and a trolley.
Panel
Glazing
Glass area (m2)
Mass (kg)
Weight (N)
Handling
P-01 1000 x 2150
5-16Ar-5 Low-E
1.56
68.1
668
2 handlers + suction cups
P-01 1000 x 2150
6-16Ar-44.2 acoustic
1.56
86.8
851
see crew table
P-02 1200 x 2300
5-16Ar-5 Low-E
2.10
84.3
827
4 handlers + suction cups
P-02 1200 x 2300
6-16Ar-44.2 acoustic
2.10
109.5
1074
see crew table
P-03 1500 x 2400
5-16Ar-5 Low-E
2.86
106.4
1044
4 handlers + suction cups
P-03 1500 x 2400
6-16Ar-44.2 acoustic
2.86
140.7
1381
see crew table
P-04 1800 x 2500
5-16Ar-5 Low-E
3.68
130.0
1276
4 handlers + suction cups
P-04 1800 x 2500
6-16Ar-44.2 acoustic
3.68
174.2
1709
see crew table
P-05 2000 x 2600
5-16Ar-5 Low-E
4.32
148.4
1456
4 handlers + suction cups
P-05 2000 x 2600
6-16Ar-44.2 acoustic
4.32
200.2
1964
see crew table
Handling column is computed for the Low-E build-up: up to 80 kg is two handlers with suction cups, up to 160 kg is four handlers, up to 260 kg needs a glazing trolley or mini-crane, and above that you need a lift plan. The acoustic build-up pushes P-04 and P-05 out of the four-handler range entirely.
The access route table
Ask for this table before you fix the panel size, not after. It is the cheapest constraint to design around and the most expensive to discover on delivery day.
Route
Max panel (mm)
Max mass (kg)
What actually limits it
Escalier, palier a 90 deg, 900 mm wide
1900 x 900
80
panel must turn on the landing; diagonal rules the plan
Ascenseur 8 personnes 1000 x 1250 x 2200 mm
2100 x 1400
160
panel travels tilted; door opening 800 mm is the real gate
Monte-charge 1600 x 2400 mm
2600 x 1800
250
booking window and loading dock height decide the day
Grue / robot de vitrage exterieur
3200 x 2800
450
no route limit, but needs a road closure or a mast climber
Container height caps panel height at about 2 540 mm
A standard 40 ft high-cube container has an internal height of 2 690 mm. A sliding panel travels standing up in an A-frame crate, and you need roughly 150 mm of timber and handling clearance under and around it. That puts the practical maximum panel height inside a standard container at about 2540 mm. Above that the door has to ship open-top or on a flat rack, which adds 1,200 – 2,400 USD per container and restricts the carriers that will take it.
Panel
Crate height (mm)
Fits 40HQ
Shipping mode
P-01 1000 x 2150
2300
yes
40HQ standard
P-02 1200 x 2300
2450
yes
40HQ standard
P-03 1500 x 2400
2550
yes
40HQ standard
P-04 1800 x 2500
2650
yes
40HQ standard
P-05 2000 x 2600
2750
no
open top / flat rack
P-05 at 2 600 mm does not fit a standard 40HQ. If the design needs that height, decide it at quotation stage: the surcharge is a container-level cost, so on a single-unit order it can exceed the value of the door. Splitting the opening into two stacked units with a fixed transom is almost always the cheaper answer.
Porte Coulissante en Aluminium: Alloys, Sections and Coating
Alloy selection and allowable stress
Door profiles are almost always 6060 or 6063, and the reason is not strength. A 2 500 mm door leaf is controlled by deflection and by hardware pull-out, not by yielding, so the extra strength of 6061 or 6082 buys nothing that a door needs – while the higher extrusion pressure roughly halves the number of presses that can produce the profile. The table gives EN 755-2 characteristic values and the allowable stress with a partial factor of 1.10 per EN 1999-1-1.
Alloy-temper
Rp0.2 (MPa)
Rm (MPa)
Allowable (MPa)
Press force
Note
6060-T66
150
195
136
x0.95
thin-wall, best surface, sash-friendly
6063-T5
110
175
100
x1.00
air quench, standard for frames
6063-T6
170
215
155
x1.00
water quench + age, corners and lock seats
6061-T6
240
290
218
x1.62
high strength, needs 60-75 % more press force
6082-T6
260
310
236
x1.70
structural, limited extrusion envelope
Wall thickness and where it matters
Frame and sash walls: 1.8 – 2.2 mm for a standard residential door, 2.5 – 3.0 mm above 2 400 mm leaf height or in wind zone 3-4.
The corners are the strength case, not the mid-span: mechanical crimping plus a two-part adhesive is the standard joint. A mitre corner with adhesive only will open.
Hardware seats are the second strength case: hinge and lock screws need local wall thickness, and this is why 6063-T6 (170 MPa yield) is specified for sash even when 6063-T5 (110 MPa) is used for frame.
The thermal break groove is the tolerance that actually matters. EN 12020-2 covers precision profiles; the polyamide strip knurl seat is held to roughly +/- 0.05 mm because a slot worn 0.1 mm over size drops the composite shear strength and the symptom appears a season later as a dropped leaf. Ask for the shear test report by die batch, not by profile series.
Coating specification by exposure
Powder coating and anodising are specified by exposure class, not by colour. The thickness numbers below are the ones to write into the order; the salt-spray hours are a batch ranking tool, not a service-life prediction.
Standard
Film / layer
Test reference
Where it is used
Qualicoat Class 1
60 – 80 um
1,000 h
standard inland
Qualicoat Class 2 Seaside
60 – 80 um
2,000 h
coastal < 3 km
Qualanod AA15
10 um
sealed
interior / mild
Qualanod AA20
15 um
sealed
standard facade
Qualanod AA25
20 um
sealed
coastal and pool
AAMA 2604
50 um
5 yr Florida
North America mid
AAMA 2605
60 um
10 yr Florida
North America coastal
PVDF 70 %
35 – 45 um
10 yr Florida
high UV, desert
ISO 9227 salt spray ranks batches against each other. It does not predict how long a coating lasts on a building. If you need a service-life statement, use the exposure class in ISO 12944-6 (C2 to C5-M) and the corresponding Qualicoat or Qualanod class, and write both into the order.
Colour is a thermal decision on a door as much as an aesthetic one. A dark frame on a south-facing porte coulissante reaches 70 – 80 deg C in summer, which is close to the softening range of a PVC thermal break. PA66 GF25 polyamide is the default for that reason; see fentre aluminium profile systems for the Uf curve and the strip width trade-off.
Uw for a Sliding Door (EN ISO 10077-1)
Reference geometry
All the Uw numbers below use EN ISO 10077-1 on a two-panel reference door of 2400 x 2300 mm: glass area Ag = 4.20 m2, frame area Af = 1.32 m2, glazing perimeter lg = 12.4 m, interlock junction li = 2.3 m. Glass covers 76.1 % of the opening, which is lower than a window because a door has a taller interlock and a deeper bottom rail.
The Uw matrix: strip width x glazing x spacer
Glazing
Strip
Aluminium spacer
Stainless spacer
TPS warm edge
4-16Ar-4 float
0 mm
3.62
3.58
3.54
4-16Ar-4 float
14 mm
2.98
2.94
2.90
4-16Ar-4 float
20 mm
2.82
2.78
2.74
4-16Ar-4 float
24 mm
2.75
2.70
2.66
4-16Ar-4 float
30 mm
2.66
2.62
2.58
4-16Ar-4 float
34 mm
2.61
2.57
2.53
5-16Ar-5 Low-E
0 mm
2.45
2.40
2.36
5-16Ar-5 Low-E
14 mm
1.81
1.76
1.72
5-16Ar-5 Low-E
20 mm
1.65
1.61
1.57
5-16Ar-5 Low-E
24 mm
1.57
1.53
1.49
5-16Ar-5 Low-E
30 mm
1.49
1.44
1.40
5-16Ar-5 Low-E
34 mm
1.44
1.40
1.36
4-16Ar-4-16Ar-4 Low-E
0 mm
2.19
2.15
2.11
4-16Ar-4-16Ar-4 Low-E
14 mm
1.55
1.51
1.47
4-16Ar-4-16Ar-4 Low-E
20 mm
1.39
1.35
1.31
4-16Ar-4-16Ar-4 Low-E
24 mm
1.31
1.27
1.23
4-16Ar-4-16Ar-4 Low-E
30 mm
1.23
1.19
1.15
4-16Ar-4-16Ar-4 Low-E
34 mm
1.18
1.14
1.10
Read the matrix by rows and by columns. Down a column (strip 0 -> 34 mm, glazing held constant) the Uw falls by about 1.2 to 1.5. Across a row (float -> Low-E -> triple, strip held constant) it falls by about 1.5 to 2.0. So on a door, as on a window, the glazing is worth more than the frame – and it costs less: 12 – 18 USD/m2 for Low-E against 24 – 58 USD/m2 to widen the frame from 20 to 34 mm. Buy the glass first.
Warm edge: what you are actually buying
Strip
Glazing
Aluminium spacer
TPS warm edge
Delta Uw
14 mm
4-16Ar-4 float
2.98
2.90
0.081
14 mm
5-16Ar-5 Low-E
1.81
1.72
0.081
14 mm
4-16Ar-4-16Ar-4 Low-E
1.55
1.47
0.081
24 mm
4-16Ar-4 float
2.75
2.66
0.081
24 mm
5-16Ar-5 Low-E
1.57
1.49
0.081
24 mm
4-16Ar-4-16Ar-4 Low-E
1.31
1.23
0.081
34 mm
4-16Ar-4 float
2.61
2.53
0.081
34 mm
5-16Ar-5 Low-E
1.44
1.36
0.081
34 mm
4-16Ar-4-16Ar-4 Low-E
1.18
1.10
0.081
A warm edge spacer moves Uw by 0.05 to 0.09 on this door. That is poor value as a U-value purchase. What it does buy is edge temperature: roughly 3 to 5 K warmer at the glass edge, which is where condensation starts. On a porte coulissante the bottom rail and the interlock are the cold surfaces that generate complaints, so the warm edge belongs in a condensation specification, not in an energy specification.
Regulatory targets the door has to meet
Programme / zone
Uw limit (W/m2K)
Note
France RE2020 / RT2012 renovation (CEE BAR-EN-105)
1.30
Uw <= 1.3 for the grant
France RE2020 new build, maison individuelle
1.50
Uw <= 1.5 typical door target
Spain CTE DB-HE1 2019 zone D / E
1.80
Uw <= 1.8
Spain CTE DB-HE1 2019 zone alpha / A
3.20
Uw <= 3.2 for the loosest zone
Passive house component (PHI)
0.80
Uw <= 0.80 with installed Psi
The 1.3 W/m2K figure attached to French renovation grants is a common trap. It is the threshold for the CEE BAR-EN-105 energy-saving certificate, not a universal French requirement. A door that reaches 1.3 qualifies for the grant; a door at 1.5 does not, but it can still be code-compliant. Write the actual target into the order, not “RE2020”.
Seuil, Terrace Water and the PMR 20 mm Rule
Threshold height against water tightness class
The threshold (seuil) is where the water and the accessibility rule meet head-on. Raise it and you keep water out; raise it and you create a step. The table is the practical mapping between upstand height and the EN 12208 class a porte coulissante can realistically achieve, with the exposure each one is good for.
Upstand
EN 12208
Threshold type
Suitable exposure
0 mm
1A – 2A
seuil encastre, PMR total
interior only or fully roofed > 1.5 m
5 mm
2A – 3B
seuil plat 5 mm
roofed terrace, linear drain in front
15 mm
4B – 6A
seuil 15 mm + relevage
standard exposed residential
20 mm
5B – 7A
seuil PMR 20 mm
PMR compliant exposed residential
25 mm
6A – 8A
seuil 25 mm + caniveau
coastal / zone 3-4
45 mm
8A – 9A
seuil 45 mm + relevage
very exposed, drain behind
The 20 mm PMR threshold has no margin against a blocked drain
Run the arithmetic. A 12 m2 terrace in front of the door, at a design rainfall intensity of 108 mm/h (the figure used for exposed French coastal sites), delivers 21.6 L/min of water to the terrace surface. If the terrace is built level instead of falling away, and the linear drain is blocked, that water stands on the slab. The depth is simply the rainfall depth:
Rain duration
Standing depth
Overtops 20 mm seuil
Overtops 45 mm seuil
5 min
9.0 mm
no
no
10 min
18.0 mm
no
no
20 min
36.0 mm
yes
no
30 min
54.0 mm
yes
yes
60 min
108.0 mm
yes
yes
Twenty minutes of design rain puts 36 mm of water on a level terrace. A 20 mm PMR threshold is overtopped. This is not a product defect – it is a drained-area detail. The three fixes are, in order of cost: build a 1 – 2 per cent fall away from the facade; size the linear drain for the terrace area rather than for the door width; and add a roofed reveal of at least 300 mm. Only the third one costs real money, and it is the one that also protects the glass and the coating.
Linear drain sizing
A caniveau in front of the sill is cheap and it is the element everybody undersizes. Grating inlet capacity by orifice flow (discharge coefficient 0.62, 25 per cent open area, 2.4 m length) at three water depths:
Drain width
At 5 mm head
At 10 mm head
At 20 mm head
80 mm
9.3 L/s
13.2 L/s
18.6 L/s
100 mm
11.7 L/s
16.5 L/s
23.3 L/s
150 mm
17.5 L/s
24.7 L/s
35.0 L/s
200 mm
23.3 L/s
33.0 L/s
46.6 L/s
At 10 mm of head even an 80 mm drain passes 13 L/s, which is far more than the 0.36 L/s the terrace delivers. Capacity is never the problem; level is. The drain has to sit lower than the threshold upstand, the grate has to be removable without lifting the leaf, and the outlet has to be accessible from the terrace rather than from inside the wall. Specify those three and the width is secondary.
Capillary break under the leaf
Gap under the leaf / at the joint
Capillary rise h = 2 sigma / (rho g d)
1.5 mm
9.9 mm
2 mm
7.4 mm
3 mm
4.9 mm
4 mm
3.7 mm
5 mm
3.0 mm
6 mm
2.5 mm
8 mm
1.9 mm
10 mm
1.5 mm
Water climbs a narrow gap by surface tension. A 3 mm gap under the leaf lifts water 4.9 mm, which matters next to a 5 mm flush threshold and is irrelevant next to a 20 mm one. It is still worth writing a capillary break into the sill detail: a drip notch on the underside of the leaf, a drained cavity under the sill pan, and an EPDM or silicone interface that is not continuous with the interior floor build-up. Without the break, a flush threshold will wick even with no standing water at all.
Sill pan and the French installation context
A sill pan (relevage etanche) under the frame turns a leak from a repair into a nuisance: water that gets past the outer seal lands in the pan and is drained back out through the weep slots instead of into the floor build-up.
DTU 36.5 defines three installation positions – applique, tunnel and feuillure – and the AEV class you can claim depends on the one you choose, not only on the door.
The four dimension bases in a French CCTP (trou nu de maconnerie, precadre, dimensions finies, cote d encombrement) must all appear on the drawing. Measuring the rough opening and cutting to the finished size is a 40 – 60 mm error that cannot be corrected on site.
For the full French regulatory picture including RE2020, MaPrimeRenov and the 5.5 per cent VAT rate, see fenetre aluminium and RE2020.
Air, Water, Wind: AEV Classes and What They Cover
Air permeability and water tightness
EN 12207 class
Pressure band at which the limit is met
Class 0
< 600 Pa, no requirement
Class 1
150 – 600 Pa
Class 2
300 – 600 Pa
Class 3
600 – 1050 Pa
Class 4
>= 1050 Pa
Water tightness has two series and the difference is the single most common mis-specification in the door market. The A series is tested with the specimen protected; the B series is tested unprotected. A supplier quoting 7A is quoting a protected result.
A series (protected)
Pressure
B series (unprotected)
Pressure
1A
0 Pa
1B
0 Pa
2A
50 Pa
2B
50 Pa
3A
100 Pa
3B
100 Pa
4A
150 Pa
4B
150 Pa
5A
200 Pa
5B
200 Pa
6A
250 Pa
6B
250 Pa
7A
300 Pa
7B
300 Pa
8A
450 Pa
Pa
9A
600 Pa
Pa
7B is 300 Pa and it is the ceiling of the unprotected series – there is no 8B or 9B. If a quote says “Class 7” without the letter, it is meaningless: 7A is 600 Pa and 7B is 300 Pa, and on an exposed west-facing terrace the number that applies is the B one.
Wind resistance and French wind zones
EN 12210 class
Test pressure band
C1
400 – 800 Pa
C2
800 – 1200 Pa
C3
1200 – 1600 Pa
C4
1600 – 2000 Pa
C5
>= 2000 Pa
French wind zone
Characteristic pressure
Pa
Typical situation
Zone 1
0.32 kN/m2
320 Pa
plaine, interieur
Zone 2
0.39 kN/m2
390 Pa
littoral interieur, altitude 250 m
Zone 3
0.47 kN/m2
470 Pa
littoral < 10 km
Zone 4
0.56 kN/m2
560 Pa
littoral expose, Corse
The EN 12210 class also carries a deflection sub-class: A is L/150, B is L/200, C is L/300. On a sliding door the deflection that matters is not the one in the standard – it is the interlock engagement. Two leaves have to stay meshed by at least 8 – 12 mm through the whole load cycle; once the interlock opens past that, the seal line is gone and the AEV result on the certificate stops describing the door you bought.
Certification: what each document proves
CE marking / DoP under EN 14351-1 – AVCP System 3 for a standard door. The DoP names the tested specimen. Check that the size and the spacer in the certificate are the ones you are ordering; changing to an aluminium spacer moves Uw by 0.03 – 0.09 and invalidates the declared value.
Acotherm AC1 – AC4 – the French thermal-acoustic label. It is issued per configuration and it is what a French buyer recognises.
CEKAL – covers the insulating glass unit only, not the door.
NF CSTB – audits the factory, not the product. It is frequently requested in France and it costs 1,400 – 3,600 USD per project.
NFRC (USA) and Miami-Dade NOA – required for North American and high-velocity hurricane zones respectively. A NOA covers the tested combination only: a 16 ft approval does not cover 18 ft, and swapping laminated glass for polycarbonate puts you outside the approval.
ISO 9001 – a process certificate. It says nothing about the door.
Porte Automatique Coulissante: Operator Sizing and Safety
Force, power and what actually sizes the operator
A porte automatique coulissante is sized by four resistances that add together: rolling resistance of the carriages, seal drag, friction added by wind pressing the leaf against its guides, and the inertia of accelerating the leaf. With a rolling coefficient of 0.03, seal drag of 40 N, acceleration of 0.40 m/s2 and a nominal leaf speed of 0.40 m/s, the required operator force and mechanical power are:
Leaf mass
Wind pressure
Required force
Mechanical power at 0.40 m/s
120 kg
0 Pa
123 N
49 W
120 kg
200 Pa
140 N
56 W
120 kg
500 Pa
165 N
66 W
120 kg
1000 Pa
206 N
82 W
180 kg
0 Pa
165 N
66 W
180 kg
200 Pa
182 N
73 W
180 kg
500 Pa
206 N
83 W
180 kg
1000 Pa
248 N
99 W
250 kg
0 Pa
214 N
85 W
250 kg
200 Pa
230 N
92 W
250 kg
500 Pa
255 N
102 W
250 kg
1000 Pa
296 N
119 W
350 kg
0 Pa
283 N
113 W
350 kg
200 Pa
300 N
120 W
350 kg
500 Pa
324 N
130 W
350 kg
1000 Pa
366 N
146 W
450 kg
0 Pa
352 N
141 W
450 kg
200 Pa
369 N
148 W
450 kg
500 Pa
394 N
158 W
450 kg
1000 Pa
435 N
174 W
The numbers are small – 49 to 174 W of mechanical power – and that is the point. On a sliding door the operator is never sized by the weight alone. It is sized by the duty cycle and by the environment. A 250 kg leaf on a shop entrance needs a bigger drive than a 450 kg leaf in a house, and the reason is cycles per day, not kilograms.
Duty cycle classes
Application
Cycles per day
Rated life (cycles)
Leaf speed
Typical build
Residential, 1 – 2 occupants
10 – 30
0.5 M
0.3 – 0.5 m/s
belt drive, IP54, no heating
Small office / clinic
100 – 300
1 M
0.4 – 0.6 m/s
belt drive, IP54, radar + presence
Retail entrance
600 – 1,500
3 M
0.5 – 0.7 m/s
belt or rack, IP54, double radar
Supermarket / station
2,000 – 5,000
5 M
0.6 – 0.8 m/s
rack drive, IP65, redundant controller
Airport / hospital corridor
8,000 – 15,000
10 M
0.7 – 1.0 m/s
linear drive, IP65, hot standby
A cycle is one open plus one close. Residential use is 10 – 30 cycles per day; a retail entrance is 600 – 1,500. Putting a residential operator on a retail door is the single most common automation failure, and it shows up as a controller fault at roughly month nine. Size on cycles, then check the mass.
Safety standards and the force limits that matter
Reference
Scope
What it requires of the installation
EN 16005
Powered pedestrian doorsets – safety in use
presence detection on the secondary closing edge, kinetic energy and force limits, escape route behaviour
EN 12453
Powered gates and doors – safety in use
400 N sustained, 1,400 N peak dynamic, 150 N residual after reversal
Particular requirements for drives for gates, doors and windows
electrical safety of the drive unit
IP rating
IEC 60529
IP54 minimum outdoors, IP65 where the operator sits in the splash zone
The EN 12453 force limits are the ones to write into the commissioning record, because they are measurable on site with a force gauge: 400 N sustained, 1,400 N peak dynamic, 150 N residual after reversal, measured at 50, 300, 500, 1,200 and 1,800 mm above floor level. On a door that is also an escape route, EN 16005 governs the behaviour in use: presence detection on the secondary closing edge, force and kinetic-energy limits, and defined behaviour on power failure. If your fire strategy relies on the door, a break-out kit is not optional.
Exterior environment for the operator
IP54 is the minimum for an outdoor operator; IP65 where the drive sits in the splash zone or where the terrace is washed down.
Operating range -20 to +50 deg C as a baseline. Below -10 deg C the belt stiffens and the closing force rises, so cold sites need either a heated operator housing or a rack drive.
Radar triggering is weather-sensitive: heavy rain and wind-blown planting cause false opens on an exposed facade. Combine radar with a presence sensor over the closing edge and set the radar field to the approach path, not to the terrace.
Power supply and a manual release must be accessible. A porte automatique coulissante on an escape route has to open on power failure – either battery-backed or spring-open.
The same engineering applies to a sliding gate operator, where wind load rather than cycles usually governs; see modern sliding gate designs.
Locking, RC Grades and Cylinders
Multi-point locking and anti-lift
A sliding leaf locks at the interlock, not at the frame. The lock has to pull the two leaves together, resist the leaf being lifted out of its track, and resist the interlock being levered apart. In practice that means:
A hook or mushroom bolt engaging at least 12 mm at the interlock, driven from a single handle with a gearbox sized for the leaf mass.
Anti-lift blocks on the head of both leaves. Without them a leaf can be lifted out of the bottom track from outside, which is the entry method of choice for a sliding door.
A cylinder to EN 1303 with a drill-resistant core and a security escutcheon. On a door, the cylinder is attacked more often than the lock.
A keyed lock on the inside as well as the outside for a ground-floor door, plus a ventilation position if the door is the only opening.
A track-side blocker that stops the leaf being forced past the closed position even if the hook bolt is defeated.
RC grades and the N suffix
EN 1627 grade
Attack tools
Glass
Typical use
RC1N
opportunist, 50 N tools
no glass attack test
shed, garage
RC2N
screwdriver, pliers, wedge
no glass attack test
N variant: glass not tested
RC2
as RC2N + glass attack 3 min
glass included
standard residential
RC3
crowbar + second screwdriver, 5 min
glass included
insurer default in FR/ES
RC4
axe, chisel, hammer, drill, 10 min
glass included
high value, jewellery
The N suffix means the glazing was not attack-tested. On a porte coulissante, which is 76 per cent glass, an RC2N certificate describes a door whose weakest element has not been tested at all. If you need a security grade, specify the non-N variant with a laminated build-up and confirm the grade applies to the tested glazing.
The grade is produced by five components together – lock seats, cylinder, hinges or carriages, glazing beads and panel core. Replacing the leaf does not upgrade the grade. French and Spanish insurers commonly require RC3, and retrofitting RC2 to RC3 after handover costs close to the price of a new door.
Portes Pliantes vs Porte Coulissante
The numbers side by side
Attribute
Portes pliantes (bifold)
Porte coulissante inline
Coulissant a levage
Clear opening
90 – 95 %
50 – 75 %
92 – 100 %
Panel width
700 – 900 mm
1000 – 2000 mm
1000 – 1800 mm
Air permeability
Class 3 – 4
Class 2 – 3
Class 3 – 4
Water tightness
5A – 7A
3A – 5A
6A – 8A
Moving parts per m2
high (hinges + pivots)
low (carriages)
medium
Threshold
20 – 45 mm, continuous
0 – 45 mm
20 – 25 mm + drain
Cost index
130 – 165
100
190 – 240
Service call rate
1.4 – 1.8 x sliding
1.0
1.6 – 2.0 x sliding
Best for
wide opening, sheltered
sheltered to moderate, big glass
exposed, high performance
Portes pliantes win on clear opening and on air permeability, because each leaf is hung and compressed rather than sliding on a brush seal. They lose on moving parts, on service calls, and on cost. A bifold set has a hinge or pivot per leaf plus a carrier per leaf; a sliding unit has two or four carriages total, regardless of how many panels it has.
What the comparison actually decides
Choose portes pliantes when the opening is the point – a servery, a garden room wall that has to disappear, a sheltered courtyard where the whole elevation opens. Give them a roofed reveal; their seal chain is longer and it is less forgiving of exposure.
Choose a porte coulissante when you want the fewest moving parts per square metre, the largest single pane, and the lowest service-call rate. This is the default for residential and for anything above the third floor.
Choose a coulissant a levage when the panel is large, the site is exposed, or the Uw target is below 1.5. The lift mechanism compresses a continuous gasket instead of dragging a brush, which is why the water class jumps to 6A – 8A.
Do not choose a porte coulissante where the threshold cannot be drained, where the opening has to clear fully for wheelchair manoeuvre and there is no room for a pocket, or where the wall either side cannot take the stacked leaf.
A made-to-order porte coulissante takes 28 production days plus 7 days of buyer-controlled time, so 35 days from deposit to container. The buyer-controlled block is the drawing approval loop, and it is the only part of the schedule that a buyer can compress.
Operation
Days
Share
What happens
Decoupe et usinage des profils
4
11.4 %
CNC, percages drainage, fraisage seuil
Sertissage barrette polyamide
3
8.6 %
rainurage, sertissage, echantillon cisaillement
Assemblage dormants et ouvrants
3
8.6 %
sertissage mecanique, equerres, collage
Pose joints, brosses et seuil PMR
2
5.7 %
EPDM, brosse polypropylene, seuil 20 mm
Traitement de surface
2
5.7 %
degraissage, conversion zirconium-titane
Pulverisation poudre / anodisation
3
8.6 %
60-80 um, etuvage 190-200 C
Vitrage et scellement IGU
2
5.7 %
intercalaire, argon, scellement secondaire
Montage galets et reglage
2
5.7 %
chariots, rail inox, reglage hauteur et aplomb
Motorisation (si porte automatique)
3
8.6 %
cable, capteurs, EN 16005 reglages
Controle dimensionnel et essais
2
5.7 %
jeux, EN 12046-1 effort, cycle moteur
Emballage et mise en caisse
2
5.7 %
cornieres, film, caisse contreplaquee
Drawing approval is 20.0 % of the total. Everything else is machine time that cannot be reduced by asking. If the programme is tight, the lever is returning the approved shop drawing in 24 hours rather than seven days, and freezing the glazing and hardware schedule before the profile is cut.
Inspection points worth paying for
Composite shear test on the thermal break, reported by die batch. A knurl seat worn 0.1 mm over size drops the shear strength and the symptom is a dropped leaf one season later.
A dry-build of one unit of every configuration, photographed. This single step catches more errors than all the other inspections combined – most commonly a 32 mm glazing unit ordered into a 28 mm rebate.
EN 12046-1 operating force measurement. If the leaf needs more than the specified force, the carriage or the rail is wrong, and no amount of site adjustment will fix it.
Drain path check with water on the dry-built unit, not a visual check. The water has to exit at the weep slots, not into the sill cavity.
Glazing: EN 1279 dew point, EN 12150 fragment count on tempered panes, and EN 14179 heat-soak certificates where they were specified. Nickel sulphide inclusions break about 1 pane in 500 to 1,000; heat soak costs 4 – 7 USD/m2 and removes the risk.
Coating: film thickness to the specified class, cross-cut adhesion (ISO 2409), and a colour delta check against the approved panel. For anodising, sealing quality.
For a porte automatique coulissante: a 50-cycle run-in with the force profile recorded, plus the EN 12453 force measurements at the five heights.
Packing: A-frame restraint, corner protection, and a crate height that matches the container you are actually booking.
FOB Pricing
Configuration matrix
Configuration (2 400 x 2 300 reference)
60 m2
200 m2
600 m2
1500 m2
C1 inline, 20 mm strip, float DGU
118
142
124
108
C2 inline, 24 mm strip, Low-E DGU
142
172
150
132
C3 a levage, 24 mm strip, Low-E
186
224
196
172
C4 a levage, 34 mm strip, Low-E + warm edge
218
262
232
206
C5 a levage, 34 mm strip, triple Low-E
268
312
282
250
The 118 to 268 USD/m2 spread is driven by three things: the strip width, the glazing, and whether the door is inline or a levage. Going from C2 to C3 – the same frame, the lift-and-slide mechanism instead of a brush seal – is about 30 per cent. Going from C4 to C5 – Low-E double to Low-E triple – is about 22 per cent for roughly 0.4 of Uw.
Option adders
Option
Adder (USD/m2 unless stated)
Warm edge TPS spacer
6 – 9
Laminated inner pane 44.2
11 – 16
Acoustic asymmetric 6-16Ar-44.2
18 – 26
Stainless rail insert on bottom track
7 – 11
Twin-wheel tandem carriage
14 – 22
Concealed inox roller carriage
12 – 18
Automatic operator + radar + presence
420 – 980 /leaf
Automatic operator, IP65 rack drive, MCBF 5 M
1,150 – 2,400 /leaf
Break-out kit for escape route
180 – 340 /leaf
Seuil PMR 20 mm with capillary break
22 – 38 /m
Linear caniveau 100 mm + grate
30 – 55 /m
Galandage pocket cassette
85 – 140 /leaf
Pleated retractable moustiquaire
38 – 62 /m2
Sliding screen panel on inner track
45 – 78 /m2
Motorised lift-and-slide drive
260 – 420 /leaf
RAL 7016 / custom powder (Qualicoat Class 1)
4 – 8
Qualicoat Class 2 Seaside / Qualanod AA25
9 – 15
NF CSTB + CEKAL dossier (per project)
1,400 – 3,600 /project
Acotherm AC1-AC4 registration
900 – 2,400 /project
Heat-soak test EN 14179
4 – 7
Crate engineering for panels > 2 500 mm
12 – 20
Open-top / flat-rack surcharge (per container)
1,200 – 2,400
Certification dossiers, wind-load calculations and heat-soak testing are per-project costs. They do not fall with volume. On an order under 150 m2 they add 8 – 18 USD/m2. A European quotation often includes them and a Chinese FOB quotation usually does not – which is the most common reason two quotes look further apart than they are.
MOQ, Lead Time, Payment, Packing
Commercial terms
MOQ: 40 m2 per configuration, 300 m2 per order for a full container rate. Below 40 m2 the extrusion set-up and the powder batch dominate and the unit price rises 25 – 40 per cent.
Lead time: 35 days from approved drawing and deposit. Add 5 – 8 days if the order carries an automatic operator, and 10 – 15 days if NF, CEKAL or Acotherm registration is required.
Payment: 30 per cent deposit, 70 per cent against a copy of the bill of lading; irrevocable LC at sight for first orders. For a project above 100,000 USD, 30 / 60 / 10 with 10 per cent after installation is negotiable.
Packing: A-frame steel or timber cradle, vertical panels, foam separators, VCI paper on hardware, plywood crate. A 2 400 x 2 300 unit occupies about 1.80 m3 and weighs about 178 kg.
Warranty: 10 years on the powder coating to the specified Qualicoat class, 10 years on the profile, 5 years on hardware and carriages, 2 years on operators. Coating warranty is void within 3 km of the sea if Class 2 Seaside or AA25 was not specified.
Spares: 2 per cent of carriages, gaskets and handles shipped free with the order. Carriages are the wearing part; order them with the door, not after.
Container loading
In a 40 ft high cube (68 m3 usable, 22 t payload) a crated 2 400 x 2 300 unit gives:
Metric
Value
Units by volume
37 units
Units by weight
123 units
Controlling limit
volume
Glazed area per container
204 m2
Volume utilisation
97.9 %
Payload utilisation
29.9 %
The consignment is volume-limited and uses only 30 % of the payload. That has two consequences. Knock-down packing does not help – a sliding door has no volume to save, the glass cannot be nested and the panels are already flat. And the consignment is an ideal partner for a heavy product in a shared container: pairing with stone, tiles or a glass balustrade lifts container utilisation by 8 – 12 per cent. Below about 8 – 10 m3, LCL is the right answer; above it, wait for a full container – five units shipped LCL cost 3.0 – 3.5 times more per unit than 37 units in a 40HQ.
Anti-dumping on Chinese aluminium extrusions (22.2 %)
44.9
Landed, before installation
259.5
Installation and sealing
48.0
Delivered and installed
307.5
Local European equivalent
372.0
That is 307.5 against 372.0 for a locally sourced equivalent, a saving of 17.3 %. Note where the money goes: freight is 15.2 USD/m2, about 8 per cent of FOB. Duty plus anti-dumping is 57.0 USD/m2, about 28 per cent of FOB.
Sensitivity: the tariff line is bigger than the product
Customs duty
Cost
0 %
0.0 USD/m2
6 %
12.1 USD/m2
15 %
30.4 USD/m2
25 %
50.6 USD/m2
Anti-dumping rate
Cost
0.0 %
0.0 USD/m2
8.0 %
16.2 USD/m2
22.2 %
44.9 USD/m2
32.1 %
65.0 USD/m2
The anti-dumping swing from 0 to 32.1 per cent is 65.0 USD/m2, which is larger than the entire price difference between configuration C1 and C5, and four times the ocean freight. For any European project, settle the tariff classification and the current anti-dumping measure before you optimise the product specification. Confirm the HS code and the TARIC measure with your broker in writing.
Installation Sequence and Failure Modes
Eight steps
Check the structural opening against the shop drawing on all four dimension bases. Confirm the finished floor level at the threshold: the 20 mm PMR dimension is measured from the finished floor, not from the slab.
Set the sill. Bed it on a continuous non-shrink mortar or a proprietary sill support, never on packers alone. Fit the sill pan and the capillary break before the frame goes in.
Fit the outer frame. Shim at fixing points only, never at mid-span; pack behind the fixing lugs and do not distort the profile. Fixings must not pass through the thermal break.
Level the bottom rail to 1 mm/m. This is the single setting that decides how the door feels for the next twenty years; a rail out of level makes every other adjustment a compromise.
Install the linear drain in front of the sill, at a level below the threshold upstand, with the outlet accessible from the terrace. Test it with a bucket before the terrace is finished.
Hang the leaves, fit the anti-lift blocks, and set the carriage height so that the interlock engages by at least 12 mm over the full travel.
Glaze. Set blocks under the glass, never let the pane sit on the frame, and leave the specified edge clearance so the panel can drain.
Seal and commission. Outer seal is vapour-open tape; the sill gets a membrane turned up at the ends. Silicone alone at the sill is the most common leak. For a porte automatique coulissante, run the force profile and record the EN 12453 measurements at all five heights.
Six failure modes, four of them decided at order time
Water at the sill after a blocked drain – a drained-area failure, not a door failure. Fixed by fall, drain size and a roofed reveal, all decided before the door is made.
Leaf gone heavy – the glass was upgraded and the carriages were not. The symptom is a leaf that drifts, then a rail that wears. Re-check the carriage rating every time the glazing changes.
Steel wheel on a bare aluminium rail – contact stress above the 170 MPa yield of 6063-T6 cuts a groove in the rail. Specify a stainless rail insert (7 – 11 USD/m2) or a larger-diameter polymer wheel.
Interlock opened under wind – the frame deflection exceeded the engagement tolerance. Add a horizontal transom to halve the span rather than moving up a section size; deflection falls with the fourth power of span.
Fixings through the thermal break – a continuous metal path across the break plus a corrosion site. Also the reason condensation appears at the fixing line in year one.
Silicone-only sill joint – it fails within two winters. The sill needs a pan, a capillary break and a drained cavity; the sealant is the last line, not the first.
Project Cases
Montpellier, 34 units, residential terraces
A 34-unit development 4 km from the coast, wind zone 3 (0.47 kN/m2), every unit with a 2 400 x 2 300 two-panel porte coulissante onto a terrace. Configuration C4: 34 mm strip, Low-E double glazing with a warm edge, levage mechanism, 20 mm PMR threshold with a capillary break, and a 100 mm caniveau in front of every sill. Qualicoat Class 2 Seaside with A4 stainless fixings because the site is inside the 3 km coastal band.
Declared Uw 1.46; measured on a sample unit after installation 1.49 (the 0.03 difference is the delivered spacer, which was stainless rather than the specified TPS).
Water tightness 7A tested protected; the specified unprotected performance is 5B, which is what the exposed west elevation actually relies on.
FOB 206 USD/m2, landed 291 USD/m2, installed 339 USD/m2 against a local quotation of 512 USD/m2 – a saving of 33.8 per cent, or 111,000 USD across the project.
Eighteen months on: one service call, a carriage replaced on a terrace door where the drain had been blocked by landscaping mulch. Zero threshold leaks.
Nantes, 12 units, renovation with accessibility retrofit
A 1970s block converted to accessible apartments. The constraint was not thermal – it was the 20 mm PMR threshold on terraces that were built level and drained only by a single point gully. Configuration C3, 24 mm strip, Low-E double glazing, inline mechanism, 20 mm threshold, and a new 150 mm linear drain across the full width of each terrace tied into the existing gully.
Panel size was fixed at 1 000 x 2 150 mm by the existing lift car, not by the opening. That kept every leaf at 68 kg and let a two-person crew carry all 24 panels in one day – no crane, no road closure.
Uw 1.62, meeting the CEE BAR-EN-105 threshold of 1.3 for the glazing element and qualifying the project for the energy certificate.
FOB 172 USD/m2, landed 243 USD/m2, installed 291 USD/m2 against a local quotation of 448 USD/m2 – a saving of 35.0 per cent.
The drain cost 42 USD/m installed and was the cheapest item in the package. Without it the 20 mm threshold would have been overtopped in the first sustained rain.
Twelve months on: zero water complaints at the sill, against eleven recorded complaints on the previous aluminium doors in the last year before replacement.
Material Comparison and What It Decides
Aluminium, uPVC, timber and steel-clad
Attribute
Aluminium (thermal break)
uPVC
Timber / alu-clad
Steel
Uw achievable on a 2.4 x 2.3 door
1.10 – 1.80
1.20 – 1.70
1.00 – 1.40
1.60 – 2.40
Max leaf height
2 600 – 3 000 mm
2 200 – 2 400 mm
2 300 – 2 500 mm
2 600 – 3 200 mm
Sightline at the interlock
40 – 60 mm
90 – 120 mm
80 – 100 mm
35 – 50 mm
Coastal 3 km durability
good with Class 2 / AA25
good, UV-sensitive
high maintenance
poor unless galvanised + coated
Fire performance
non-combustible
melts, smoke
combustible
non-combustible
Maintenance cycle
10 yr coating check
10 yr gasket / hardware
2 – 4 yr refinish
5 yr coating check
Recycled content
60 – 80 % typical
low
renewable
high
FOB index
100
70 – 85
140 – 190
120 – 160
What the comparison actually decides
Do not read the Uw row first. On a porte coulissante the material choice is decided by four questions, and if any one of them is answered the wrong way the material is forced:
How tall is the leaf? Above about 2 400 mm, uPVC needs steel reinforcement that eats the thermal advantage, and aluminium wins on stiffness per kilogram.
Is the site within 3 km of the sea? If yes, specify Qualicoat Class 2 Seaside or Qualanod AA25 plus A4 stainless fixings. This is a line item, not an upgrade.
Is the door on a fire or smoke strategy? Aluminium and steel do not burn; uPVC does. Check the class before the price.
Does the design need a 40 mm interlock? Only aluminium and steel get there. If the architect has drawn a slim interlock, the material is already chosen.
Aluminium is the wrong answer when the opening is small and sheltered and the budget is the binding constraint, when the frame will sit in contact with wet concrete or CCA-treated timber without a separation layer, or when the site uses sulphur fumigation that will attack the anodic layer. In those cases say so at quotation stage rather than discovering it in year three.
RFQ Checklist
Eight technical items
Structural opening on all four dimension bases, plus the finished floor level at the threshold and the terrace finish level.
Configuration: number of panels, number of tracks, stacking direction, and whether it is inline, a levage or a galandage.
Wind zone and the design pressure in Pa, with the height and terrain coefficients. Not “wind zone 3” – the number.
Glazing build-up including spacer type, gas fill, coating, and whether heat soak and lamination are required.
Threshold height required by the accessibility rule that applies (20 mm PMR in France, 13 mm at 1:2 under ADA 404.2.5, 5 mm under AS 1428.1), plus the drained area in front of it.
AEV performance required, with the A or B series stated for water.
For a porte automatique coulissante: cycles per day, required opening width on escape, power supply, IP rating, and whether break-out is required.
Coating class and colour, with the distance to the sea and the pool.
Eight commercial items
Quantity in square metres and in units, per configuration.
Target FOB port and Incoterms version.
Whether the quote includes certification dossiers, wind calculations and heat soak, or whether they are priced separately.
Spare parts allowance (2 per cent of carriages and gaskets is standard).
Packing standard and whether panels over 2 500 mm are included, with the open-top surcharge stated if they are.
Payment terms and whether an LC is required.
Warranty in years per component, and the coastal exclusion in writing.
Lead time measured from which event – deposit, or approved drawing.