Buyers use the words sunroom, glass house, conservatory and glass greenhouse interchangeably in enquiries. On a Chinese factory order sheet they are four different products, with four different glazing ratios, four different heating assumptions and four different price bands. Getting the classification wrong at enquiry stage is the single most expensive mistake in this category, because it is discovered after the profiles have been extruded.
Rather than argue about vocabulary, specifiers can separate the four types on three measurable variables. The first is occupancy class — is the space a habitable room (a room people sit in, with furniture and a floor finish) or a growing structure (a room plants live in, with benches, irrigation and 70-95% relative humidity)? The second is heating setpoint — 20-22°C year-round, seasonal 12-18°C, or frost-free only at 4-6°C. The third is glazing ratio, the share of the envelope that is transparent: 45-60% for a conservatory with dwarf walls, 75-90% for a glass room, 95-100% for a greenhouse.
Once those three numbers are on paper, the correct product follows mechanically. A 100% glazing ratio with a 20°C setpoint is physically possible but thermally indefensible — the heating load will exceed 250 W/m² of floor area in a temperate winter, which is roughly three times what a residential room uses. That is why the practical pairings in the table below cluster the way they do.
A 24 m² lean-to quoted as a 3-season glass room and then used as a 4-season habitable space produces a heating load of roughly 4.4 kW at a -5°C design temperature, against 1.7 kW for a correctly specified envelope. The retrofit is not a matter of changing glass: the wall profiles will have a 14.8 mm thermal break where a 24-30 mm break was needed, the roof rafters will have no condensation channel, and the slab will have no perimeter insulation. Total rebuild cost typically lands at 85-110% of the original kit value.
The enquiry phrase sun room glass house outdoor usually describes a freestanding structure in a garden: not attached to the dwelling, no shared wall, four exposed elevations. That changes three things relative to a lean-to. Wind exposure rises from sheltered to open country (basic velocity pressure roughly 1.3-1.6× the sheltered value), the structure has no thermal buffer from the house, and the base has to be a full slab or a ring beam on pad foundations rather than a strip footing against an existing wall.
Practically, freestanding units are built with a 120×60×3 mm perimeter ring beam, M12 cast-in anchors at 900 mm centres, and a 150 mm reinforced slab with 100 mm XPS perimeter upstand. Freight also changes: a freestanding kit has roughly 1.35× the profile length of a comparable lean-to, which raises the FOB figure by 12-18% per m² even though the glass area is nearly identical.
A glass roof is a structural element that happens to be transparent. The failure mode in the field is rarely breakage — it is deflection. A rafter that sags 20 mm over a 2.4 m span will not collapse, but it will load the insulating glass unit in bending, and IGUs tolerate very little of that before the edge seal starts to leak.
Take a representative module: rafter span 2.4 m, rafter spacing 0.9 m, dead 0.42 kN/m² plus snow 1.00 kN/m². Line load w = 1.42 × 0.9 = 1.28 kN/m. Bending moment M = wL²/8 = 0.92 kN·m.
6063-T6 extrusion has a characteristic yield of 170 MPa. With a partial factor of 1.65 the allowable stress is about 103 MPa. Both candidate sections clear the stress check easily — the governing criterion is stiffness, not strength.
The 100×50×3 rafter is at 61.5 MPa — 60% of allowable — and still unusable. Anyone sizing a glazed roof on stress alone will specify a section that sags L/114. Note also that 120×60×3 at L/202 clears the common L/180 limit but would fail a specification written as L/200, which is why the limit has to be stated in the enquiry, not assumed.
Net uplift on a 20 m² glazed roof at -1.2 kN/m² wind minus 0.42 kN/m² dead is 0.78 × 20 = 15.6 kN. That load is carried entirely by the fixings into the wall plate or slab, because the roof weighs less than the wind trying to remove it. Six M10 chemical anchors in C25/30 concrete at 100 mm embedment give roughly 12-14 kN allowable tension each, or 75-84 kN total — a utilisation of about 20%, which is the correct order of magnitude once you account for edge distance and cracked-concrete reduction factors.
The glass itself is retained against uplift by pressure plates or structural silicone, not by gravity. For roof glazing, specify a continuous mechanically fixed pressure plate system with a captive gasket; a heel-bead-only silicone installation has no defined uplift resistance and is not accepted by most European notified bodies.
Every enquiry for a glass room eventually turns into the same argument: the client wants maximum daylight and a low heating bill, and those two pull in opposite directions. The number that resolves it is the g-value (EN 410) — total solar energy transmittance — called SHGC in the NFRC system. U-value tells you what happens at night; g-value tells you what happens at 14:00 in July.
A clear double-glazed unit has a g-value of about 0.72 and a light transmittance of 0.79. Aggressive solar-control coatings will take g down to 0.30-0.36, but light transmittance falls to 0.48-0.60 and the glass visibly tints. The selectivity index (LT/g) is the honest way to compare: 0.79/0.72 = 1.10 for clear glass, 0.60/0.36 = 1.67 for a modern selective coating. A coating with a selectivity index above 1.4 is worth the surcharge; below 1.25 you are buying darkness, not control.
Note the roof rows. A single laminated roof pane has a Ug of 5.4 W/m²K — worse than single glazing in a wall, because it is horizontal and warm air sits against it. Where the space is heated, the roof must be an insulating unit with a laminated inner pane, not a single pane. Where the space is a growing structure, the 5.4 figure is irrelevant, which is exactly the classification point from the first section.
Solar gain is linear in g: Q = A × g × I. Using a 32 m² glazed area facing the equator and a design irradiance of 700 W/m², clear glass gives 32 × 0.72 × 700 = 16.1 kW of instantaneous gain. Moving to a 0.36 coating cuts that to 8.1 kW — a 8.0 kW reduction for a glass surcharge of $640-830 on a 32 m² project. Mechanical cooling to remove 8 kW of gain costs roughly $2,400-3,600 in equipment and 3,000-4,500 kWh per season. The coating pays for itself inside one cooling season in any climate with a design temperature above 30°C.
The persistent myth in this category is that a glass room overheats because it is under-ventilated, and that more opening area solves it. The arithmetic says otherwise, and this is worth showing before a client spends money on motorised vents they do not need.
Driving pressure difference Δp = g · h · (ρout − ρin). With a 2.5 m stack height and an 8 K indoor-outdoor difference (ρ = 1.197 and 1.165 kg/m³), Δp = 9.81 × 2.5 × 0.032 = 0.78 Pa. Theoretical velocity v = √(2Δp/ρ) = 1.16 m/s; after discharge and inlet losses, the realistic figure is 0.55-0.70 m/s. With 1.5 m² of low-level inlet and 1.5 m² of ridge outlet, the effective area is A = 1.5/√2 = 1.06 m², giving roughly 0.7 m³/s.
That airflow removes Q = ρcV̇ΔT = 1.2 × 1005 × 0.7 × 5 = 4.2 kW at a 5 K indoor-outdoor differential. Set that against the 16.1 kW of clear-glass solar gain and the conclusion is unavoidable: ventilation cannot fix a clear-glazed sunroom. It is off by a factor of nearly four.
Applied in that order the three levers cost about $4,300-6,100 on a 32 m² room and bring peak temperature within 4-6 K of ambient. Applied in reverse — vents first, glass last — the same budget produces a room that is still 12-15 K above ambient at peak, because the ventilation lever is capped by physics while the g-value lever is not.
Habitable spaces use 6-10% of floor area as openable area; growing structures use 15-20% because the humidity load, not the temperature, is what has to be removed. A gable-mounted exhaust fan rated at 1.2-1.8 m³/s adds forced ventilation for the 6-10 weeks per year when stack effect alone is insufficient.
Roughly one in six enquiries for a glass house turns out to be a horticultural build. The frame geometry is similar, so it is tempting to ship the same kit. It should not be: three specification items diverge sharply, and the warranty claims come from them.
Horticultural glass is 4 mm float with a high light transmittance (0.88-0.90) and deliberately low solar reflectance; it is not an insulating unit and not safety glass by default. Residential glazing is a sealed IGU with a Low-E coating. Where a growing structure is glazed with residential Low-E units, photosynthetically active radiation drops by 12-18% and measured yield follows. Where a habitable room is glazed with 4 mm float, the U-value is 5.8 W/m²K and the heating bill is roughly 4×.
Inside a growing structure, relative humidity sits at 70-95% and the glass is the coldest surface in the enclosure, so condensation is continuous rather than occasional. The roof needs a minimum fall of 1.5% (about 0.86°) so condensate runs to the gutter rather than dripping onto the crop; a glazed roof with integrated condensation channels allows the fall to drop to 1.0%. Gutter capacity should be sized for 100% of roof area draining in one hour at the local rainfall intensity — for 80 m² at 60 mm/h that is 4.8 m³/h, which needs a 100 × 75 mm gutter and two 63 mm downpipes.
All aluminium in contact with that environment must be either powder-coated to Qualicoat Class 2 (or AAMA 2604) or anodised to 15 µm minimum. Mill-finish extrusion in a greenhouse will show white oxide bloom within 18-24 months and the claim will be rejected as an environment issue, not a product defect.
The G3-to-G4 jump is not a pricing anomaly — it is the difference between an unheated growing structure and a heated, thermally broken, safety-glazed habitable envelope. For buyers who need both, the usual answer is a partition: a G3 growing bay with a G4 seating area, sharing one ridge but with separate drainage and separate glazing specs. See the glass greenhouse build data for the horticultural side and the veranda and patio enclosure drainage detail for the habitable side.
A conservatory is a glass room with its lower 500-900 mm replaced by a solid wall. That one change moves the glazing ratio from 85% to about 55%, cuts the heating load by 30-40%, and — more importantly for European compliance — brings the structure within reach of Part L / GEG limits that a full-height glazed room cannot meet.
The price rises 37-89% while the heat loss falls 27-42%. Whether that is worth it depends entirely on the heating degree-days and the local energy price; at 3,400 HDD and $0.19/kWh the 900 mm dwarf wall pays back in 7-9 years on heating alone, at 1,800 HDD it does not. This is a calculation the buyer should do with their own energy price, not a spec the factory should impose.
Sunroom and glass house frames are extruded from the 6xxx series. The three variables the factory needs confirmed before cutting a die are alloy temper, nominal wall thickness and thermal break width.
6063 is chosen over 6061 for almost everything despite the lower strength, because its extrusion speed is 2-3× higher and its surface quality after anodising is better. Using 6061 in a sunroom frame adds roughly 30-40% to the profile cost for no benefit unless a member is genuinely span-limited.
The break is a polyamide strip, PA66 with 25% glass fibre (PA66GF25), crimped between the inner and outer aluminium halves. Its width is the single strongest lever on frame U-value.
Powder coating is applied after chrome-free pre-treatment (zirconium/titanium conversion, or chrome passivation where the client accepts it). Film thickness 60-80 µm measured per ISO 2360, cured at 190-200°C metal temperature for 12-15 minutes. Qualicoat Class 1 gives 1,000 h neutral salt spray and 1 year Florida exposure; Class 2 (or AAMA 2605 for the US) gives 2,000 h and 5-year gloss retention above 50%. Anodising to 15-20 µm (AA15/AA20) is used for coastal and greenhouse environments because it does not chalk.
Walls and roofs of a glass house do not follow the same glazing rules. A wall unit is a vertical insulating element; a roof unit is a horizontal element that must also carry a person, shed water, and survive impact from above.
The laminated interlayer thickness matters: 0.76 mm PVB is the common minimum, but roof units in snow regions should be 1.52 mm or SGP (ionomer), which retains roughly 5× the stiffness of PVB at 50°C. SGP adds $14-22 per m² of roof glass.
Condensation forms when the internal glass surface drops below the dew point. At 21°C and 50% RH the dew point is 10.2°C. Internal surface temperature is Tsi = Ti − (U/Rsi)(Ti − To) with Rsi = 0.13 m²K/W. For clear double glazing at U = 2.8 and To = 0°C: Tsi = 21 − (2.8/0.13 × … ) — more usefully, Tsi = 21 − (0.13 × 2.8 × 21) = 13.4°C, above dew point. For single roof laminate at U = 5.4: Tsi = 21 − (0.13 × 5.4 × 21) = 6.3°C, below the 10.2°C dew point — the roof will run with water. That is the arithmetic behind the common complaint “my sunroom roof drips”.
Two systems are used. Mechanically retained: an aluminium pressure plate screwed to the rafter at 250-300 mm centres, with EPDM gaskets both sides and a snap cover. Structurally bonded: neutral-cure silicone (usually two-part, e.g. a 2-part structural silicone to ETAG 002) bonding the unit to the rafter with a temporary mechanical restraint. Bonded systems look cleaner but require documented substrate adhesion testing and a defined cure regime; for export projects with local installers, mechanical retention is the lower-risk choice and costs $9-16/m² more.
Quotations in this category are normally given per m² of floor area for a complete kit, and per m² of glass for glazing upgrades. All figures below are FOB Foshan / Guangzhou, in USD, for orders of 60 m² or more, on a 30/70 T/T basis, excluding tooling for new profiles.
Sunroom kits are light for their volume: 22-28 kg/m² of floor area against a container payload of about 26 t. A 40HQ (68 m³ usable) fills at 420-560 m² of kit, weighing 13-17 t — volume-limited, using 92-96% of the box and 55-65% of the payload. Ocean freight on a Foshan-to-Rotterdam or Foshan-to-Houston move therefore lands at $16-31 per m² of floor area at recent rate levels, but swings to $52-78/m² in a peak season. On a $250/m² kit, freight is 6-12% of FOB in a normal market and up to 31% in a bad one — a far bigger swing than any glazing upgrade in the table above.
Sunroom orders are engineering projects rather than catalogue purchases. The commercial terms below are what a Foshan factory will normally agree to on a repeat basis.
A complete glass house is a structure, so it sits awkwardly between two regulatory worlds: the load-bearing aluminium frame falls under construction products rules, and the opening windows and doors inserted into it fall under fenestration rules. Many suppliers mark the whole assembly CE and hope the inspector does not look closely.
Three gaps appear repeatedly. First: EN 14351-1 test results are size-dependent. A window tested at 1,200 × 1,500 mm and reported at Class 4 air permeability and Class E900 watertightness does not carry those classes to a 2,400 × 2,400 mm unit of the same series; the standard permits extrapolation only within defined limits, and most buyers never check. Second: NFRC simulations are per-configuration — change the spacer or the glass thickness and the label is void. Third: EN 1090-1 covers the aluminium members but says nothing about the glazing infill, so a “CE-marked sunroom” may have a certified frame and uncertified glass.
Ask for three documents with any quotation above 100 m²: the DoP (Declaration of Performance) with its declared values and the standard cited, the raw test report with test specimen dimensions, and the certificate’s validity dates. Ten minutes with those three will tell you more than any brochure.
Site problems outnumber factory problems in this category by a wide margin. The sequence below is the one used on export projects with local installation crews, and it is ordered deliberately: nothing that is difficult to reach is installed early.
Before handover: every opening sash operates with a force under 60 N (EN 13115 class 2); every locking point engages with the handle at 90°; weeps run free when tested with 200 ml of water; ridge vent opens and closes through full travel with a current draw within 10% of the motor rating; all glass units are free of edge defects visible at 1 m in reflected light; drainage carries 100% of roof area at design rainfall for 10 minutes with no ponding deeper than 2 mm. Documenting these eight items takes 45 minutes and removes most post-handover disputes.
The following are representative export builds shipped from Foshan in the last 24 months, with the specification that was ordered and the performance that was measured afterwards.
C3 specification: 24 mm PA66GF25 thermal break, 2.0 mm walls, 5 + 12Ar + 5 Low-E walls, 6 + 12Ar + 6.38 laminated roof with a 0.38 g-value, 150 mm RC slab with 100 mm XPS upstand. Kit FOB $10,240 ($320/m²); freight and duty to Munich $3,180; local base and installation $8,900. Envelope U-value measured in situ by heat-flux meter: 1.71 W/m²K. Auxiliary heating demand at the -12°C design point was 2.1 kW against the 5.9 kW the client’s previous full-height double-glazed room needed. Annual heating consumption 2,140 kWh at 3,600 HDD, i.e. 67 kWh/m²·yr — about half the German single-family average, which is what a 4-season classification is supposed to deliver.
C4 specification with a motorised louvre roof over 24 m² (shading coefficient 0.42 when closed) and 0.32 g-value selective glazing throughout. Kit FOB $52,800 ($550/m²); the louvre roof alone was $3,600 of that. Monitored over one August: peak interior temperature 29.1°C at 38.4°C ambient and 940 W/m² horizontal irradiance. Without the louvre closed the same day reached 36.8°C — so the shading lever was worth 7.7 K, against 4.2 K from the ventilation package (4 ridge vents + 2 gable fans, 0.9 m³/s measured). Combined cooling load 2.4 kW, which a single mini-split handles.
G3 configuration: 100×50×3 posts, 120×60×3 rafters at 2.4 m span, 4 mm horticultural glass with tempered ridge panes, 22% vent area (46 m², of which 14 m² motorised ridge), 1.5% roof fall, AA20 anodised finish rather than powder. Kit FOB $29,400 ($140/m²); 40HQ shipped 210 m² at 62 m³ and 5.8 t — 91% of volume, 22% of payload. Measured annual heating 41 kWh/m² against the 58 kWh/m² of the previous polycarbonate structure it replaced, a 29% reduction attributable to the higher light transmittance and the tighter gasket system rather than to the U-value, which barely differs.
Two patterns are consistent across all three. Freight per m² is 4.6-8.4× higher on the LCL move (Case A) than on the consolidated container (Case C), which is why orders below 8-10 m³ should be consolidated with other product lines. And local base plus installation runs at 62-87% of kit FOB — buyers who budget only for the kit will be roughly 70% short.
Aluminium dominates the export market for glass houses, but it is not the right answer everywhere. The comparison below uses delivered frame cost, not glazing, and holds the glazing specification constant so the frame differences are visible.
uPVC wins on frame U-value and on price, and it is the correct answer for a small 3-season glass room in a temperate climate where nobody needs a 3.6 m rafter. It loses on sightline width and on freight weight — 155% of the aluminium figure means a 40HQ hits the payload limit before the volume limit, which quietly raises the freight per m². Steel is the only material that reaches 5 m spans with a 40 mm sightline, which is why it appears in orangerie lantern roofs, but at 240% of the freight weight it is expensive to ship.
These are the recurring items in post-installation claims on glass room projects, in rough order of frequency, with the specification change that prevents each one.
Mechanism: internal roof surface below dew point, as calculated in the glazing section — single laminate at U 5.4 gives Tsi = 6.3°C against a 10.2°C dew point. Fix: insulating roof unit to Ug 1.2, warm-edge spacer, and 0.3-0.5 ACH background ventilation. A genuine leak, by contrast, wets the same spot every time it rains regardless of indoor humidity; a condensation complaint appears on cold still mornings with no rain.
Mechanism: rafter or ridge sized on stress instead of deflection, giving L/114 rather than L/180 or better. Fix: state the deflection limit in the enquiry; require the supplier to return Ix and the calculated mid-span deflection for the governing load case, not just “complies with the standard”.
Mechanism: concrete breakout cone. An M10 at 30 mm edge distance retains only 45-60% of the capacity it has at 60 mm. Fix: 60 mm minimum edge distance, 100 mm embedment, and a perimeter thickening to 300 × 300 mm where fixings land near the slab border.
Mechanism: acetic acid released during cure migrates into the PVB interlayer and produces edge haze and eventual delamination, typically visible 6-18 months after handover. Fix: specify neutral-cure (alkoxy or oxime) silicone in writing on the glazing schedule, and reject any tube on site that is not labelled.
Mechanism: shear creep above 60-70°C, which a dark powder-coated frame reaches in summer. The two aluminium halves progressively separate; the symptom is a door that drops and will not latch. Fix: require the EN 14024 report and the strip manufacturer’s name, and add a 1.5 kN/m shear test to the incoming inspection for orders above 200 m².
Mechanism: gutter sized for half the roof area, or a downpipe sized for the average rainfall rather than the 2-minute design intensity. Fix: size for 100% of plan area at the local 1-in-5-year 5-minute intensity; on a 40 m² plan in a 60 mm/h zone that is 2.4 m³/h, needing 75 × 50 mm gutter and one 63 mm downpipe per 20 m of eaves.
Mechanism: 16.1 kW of peak gain against 4.2 kW of achievable ventilation removal. Fix: g-value 0.30-0.38 on the equator-facing and roof planes, 0.55-0.65 on the polar-facing plane where winter gain is useful, and external shading before internal blinds. Internal blinds reject 20-35% of the energy; external shading rejects 55-70%, because the heat never enters the room.
A glass room is assembled from the same component families as the rest of the fenestration package. The links below point to the specification data for each part, so the wall openings, the roof glazing and the shading can be specified consistently.