Blog

Home   >   Casement Windows   >   Top 10 Ventanas de Aluminio Casement Window Specs to Compare in China

Top 10 Ventanas de Aluminio Casement Window Specs to Compare in China

Ventanas de aluminio - aluminum casement windows with thermal break frames installed on a residential apartment building in China, one sash open with insect screen
ROGENILAN aluminum casement windows (ventanas de aluminio practicable), 24 mm thermal break, double glazing, on a residential building in China.
Ventanas de aluminio reach export buyers as a specification problem before they become a price problem: frame series, wall thickness, thermal break width, glazing stack-up, hardware load, and the test standard the shipment must pass. This article works through the ten specification lines that decide whether a casement window quote from a Chinese factory holds up on site, with measured U-value stack-ups, a worked mullion deflection check, screen free-area math, FOB price tables by series and size, certification routes for the EU, North America and Australia, and a landed-cost case study on 96 windows shipped to Guadalajara.
FOB price
$96–204/m²

Uw range
1.16–3.09 W/m²K

Wall thickness
1.4 / 1.8 / 2.0 mm

MOQ
30 m² mixed

Lead time
25–35 days

Contents
1. What the Spanish Spec Actually Names
2. Aluminum Window Frame: Series and Thermal Break
3. Casement Sash Geometry and Structural Limits
4. Double Glazing: Uw Stack-Up and Condensation
5. Casement Windows with Screens: Free Area
6. Casement Windows to the Australian Standard
7. The Top 10 Spec Lines to Compare
8. FOB Pricing: Series, Size, Options
9. Certification Path by Market
10. Installation: 8 Steps, 3 Failure Points
11. Case Data: 96 Windows to Guadalajara
12. MOQ, Packing, Lead Time
13. RFQ Checklist

What the Spanish Spec Actually Names — and Where Importers Lose Money

A buyer searching ventanas de aluminio usually holds a Spanish-language drawing from a local architect. The factory quote that follows is only as good as the translation of eleven terms that carry real cost. The table below maps the terms we receive on Latin American and Spanish RFQs to the English spec line a Chinese fabricator will actually machine.

Spanish term on drawing English spec line What it changes in the quote
Ventana practicable Casement window (side-hung) Hinge side, friction stay length, sash width limit
Ventana practicable hacia arriba Top-hung / awning window Stay type changes; sash can be wider, hardware rated differently
Hoja Sash / leaf Determines weight per hinge; drives hardware class
Marco Frame (outer fixed profile) Profile series depth, wall thickness
Premarco Sub-frame (installation frame) Adds 8–12 USD/m perimeter; changes site waterproofing detail
Rotura de puente térmico Thermal break (PA66 GF25 strip) Strip width 14/24/34 mm changes Uf and price non-linearly
Doble vidrio / cámara Double glazing / insulated glass unit Cavity 12 or 16 mm; argon and Low-E are separate line items
Mosquitero Insect screen Roller vs fixed frame; changes free area, see Section 5
Herrajes Hardware (hinges, stays, handles) Brand tier shifts 12–25 USD/m²
Gomas / junquillo Gaskets / glazing bead EPDM vs TPE; bead type fixes glazing from inside or outside
Sellado perimetral Perimeter sealing Silicone vs MS polymer; site detail, not factory

Handing and Opening Direction Conventions

Spanish drawings mark handing as “hoja derecha” (right-hand leaf). Chinese fabricators work to the convention “viewed from outside, hinge side named first”. These two conventions are mirror images for casement pairs: a Spanish right-hand-first drawing quoted as a Chinese right-hand casement puts both hinges on the wrong side, and the error is only discovered at installation. We re-draw every RFQ in a top-view elevation with hinge sides marked before quotation; ask any factory to do the same and attach the re-drawn elevation to the proforma invoice.

The Three Terms Most Often Quoted Wrong

Aluminum Window Frame: Series, Wall Thickness and Thermal Break Width

Chinese casement systems are sold by frame depth in millimetres (60, 70, 80, 90 series). The number is a starting point only: two “70 series” frames from different extruders can differ by 40% in frame area share, which is what actually sets the U-value. What is comparable across quotes is wall thickness, thermal break strip width, and the resulting frame U-value Uf.

Series (frame depth) Typical wall thickness Thermal break strip Typical Uf (W/m²K) Max sash weight FOB range (USD/m²)
60 series 1.4 mm none / 14 mm 5.7 (no break) / 3.4 40 kg 55–85
70 series 1.4–1.8 mm 14–24 mm PA66 GF25 2.6 at 24 mm 65 kg 95–145
80 series 1.8–2.0 mm 24 mm PA66 GF25 2.4–2.6 80 kg 130–175
90 series 2.0 mm 34 mm PA66 + foam 2.0–2.1 110 kg 170–220

Alloy is 6063-T5 or 6063-T6 extruded to EN 12020-2 or GB/T 8478 (the Chinese product standard for aluminum windows, which sets minimum wall thickness at 1.4 mm for frame members on exterior openings). Powder coating is polyester TGIC-free, 60–80 µm, cured at 180–200 °C; PVDF (for coastal or high-UV sites) is an option uplift, not a base build.

Thermal Break Width Drives Uf Non-Linearly

The PA66 GF25 strip is the single most consequential line in the frame. Widening it is cheap at the die and expensive to change later, because the whole system (gaskets, glazing bead, hardware screw boss) is keyed to it. Measured frame U-values on the same 70-series geometry: 14 mm strip → Uf 3.4; 24 mm → 2.6; 34 mm with foam infill → 2.0–2.1. Going from 14 to 24 mm costs roughly 6–9 USD/m² of profile and buys 0.8 W/m²K of frame U; going from 24 to 34 mm costs 12–15 USD/m² and buys 0.4–0.6. The first step is the efficient one, and it is also the step that unlocks Low-E argon units without condensation risk (Section 4).

Wall Thickness: What the Certificate Must Show

GB/T 8478 requires ≥1.4 mm on main load-bearing members; European jobs quote EN 12020-2 tolerances with 1.2–1.4 mm common on sliding and 1.4–2.0 mm on casements. Two failure modes push buyers to 1.8–2.0 mm: screw pull-out on heavy sashes (Section 3) and transport damage. If a quote shows 1.2 mm on a 70-series casement frame, the friction-stay screws have 2 mm of engagement per wall instead of 2.6–3.0 mm, and stay pull-out under wind load becomes the weak link. Ask for a section drawing with wall thickness called out, not a photo.

Aluminium Casement Windows: Sash Geometry and Structural Limits

Casement geometry fails on deflection, not on stress. The centre mullion of a two-sash casement carries wind from both sashes; at 2.0 kPa design pressure (a common commercial spec) and a 1.2 m tributary width, the load is 2.4 kN/m over a 1.5 m span. The table below is a worked check on rectangular reinforcement sections in 6063-T6 (E = 70,000 MPa, allowable stress taken at 70 MPa for window hardware-supported members, deflection limit L/200):

Reinforcement section I (mm⁴) W (mm³) Bending stress σ (MPa) Deflection δ (mm) Verdict vs L/200 = 7.50 mm
60×40×2.0 102,272 5,114 132.0 22.10 FAIL (δ = 2.9× limit)
80×44×2.0 162,560 7,389 91.4 13.90 FAIL
100×50×1.8 239,158 9,566 70.6 9.45 FAIL (both marginal)
100×50×3.0 374,392 14,976 45.1 6.04 PASS
120×60×3.0 664,092 22,136 30.5 3.40 PASS (2.2× margin)

The practical read: a two-sash 70-series casement at 1.5 m height needs the 100×50×3.0 mullion, not the 60×40 profile that most quotes at this size default to. Stress is not the binding check — 60×40×2.0 sits at 132 MPa against a 160 MPa yield, looks fine on a stress report, and still deflects 22 mm, which bows the meeting stiles apart, opens the gasket line, and shows up as the water leak in year two.

Sash Weight and the Friction Stay

A 600×1400 mm sash with 4-16-4 double glazing weighs: glass 0.655 m² × 2.5 kg/mm·m² × 8 mm = 13.1 kg, plus sash frame 4.0 m perimeter × 1.15 kg/m = 4.6 kg → 17.7 kg total. The stay must also carry wind: at 2.0 kPa the load on that sash is 1.68 kN, producing about 1.68 kN of axial force in the stay arm at a 300 mm attachment offset. Four 4.8×32 screws in a 2.0 mm wall give 3.2–4.8 kN of pull-out capacity, so the screw count — not the stay rating — is what sets the limit. This is why the same hardware line is quoted with different screw schedules at 1.4 mm and 2.0 mm wall thickness.

Opening Angle and Wind Catch

A casement sash open at 90° presents its full area to suction as well as pressure; the stay and hinges see a reversed load in a gust. Stays are rated for the sash in the closed position and are not equivalent in the open state. For typhoon-exposed sites we restrict casement sashes to 600 mm width, keep the friction stay ≤ 400 mm, and fit a limit arm (restrictor) rated to hold the sash at 100 mm opening — a 3–6 USD item that removes the most common wind-season failure.

For deeper frame and hardware data on the same category, see our aluminium windows and doors frame and glazing breakdown and the casement window factory spec sheet.

Double Glazed Aluminium Windows: What the Cavity Really Buys

The glazing stack-up and the frame are priced separately and must be quoted separately, because the same “double glazed” label covers a 3:1 spread in window U-value. The stack-up below is computed per EN ISO 10077-1 for a 1,200×1,500 mm casement (frame area share 0.45 m², glass 1.35 m², glass edge length 4.8 m) — the geometry of the most common export size:

Configuration Uf (W/m²K) Ug (W/m²K) Spacer psi (W/mK) Uw (W/m²K)
No thermal break, 4 mm single glass, aluminum spacer 5.70 5.80 0.08 5.99
14 mm PA66 strip, 4-12-4 air fill, aluminum spacer 3.40 2.70 0.08 3.09
24 mm PA66 strip, 4-16-4 Low-E argon, steel spacer 2.60 1.10 0.06 1.64
24 mm PA66 strip, 4-16-4 Low-E argon, warm edge 2.60 1.10 0.04 1.58
34 mm PA66 + foam, 4-16-4 Low-E argon, warm edge 2.10 1.10 0.04 1.46
34 mm PA66 + foam, triple Low-E argon, warm edge 2.10 0.70 0.04 1.16

Read the jumps: single-glazed non-thermal to 14 mm strip with air cavity is a 2.9 W/m²K improvement for roughly 25–30 USD/m²; from there, 24 mm strip + Low-E argon + steel spacer buys another 1.45 W/m²K for 35–45 USD/m²; the warm-edge spacer alone (psi 0.06 → 0.04) is worth 0.05 W/m²K on this window for 2–4 USD/m² — the cheapest line item in the whole table. Triple glazing buys 0.42 W/m²K more but adds 9–12 kg per sash, which pushes the hardware class up (Section 3).

Condensation: The Number That Rejects Frames on Site

Interior condensation is what buyers actually complain about, and it is computable. Surface temperature of the inner face, θsi = 20 °C − (Rsi/Rtot)·ΔT with Rsi = 0.13 m²K/W and a 0/°C exterior, gives the following thresholds. The dew point at 20 °C / 65% RH is 13.2 °C; at 75% it is 15.4 °C; at 85% it is 17.4 °C.

Uw (W/m²K) θsi at 20/°C outside Condensation begins above Practical climate verdict
3.09 11.97 °C 59.9% RH Damp-heat climates only; coastal Spain / Gulf coast will sweat
1.64 15.75 °C 76.6% RH Temperate interiors; ventilate kitchens and baths
1.58 15.94 °C 77.6% RH Same class; warm edge is cheap insurance
1.46 16.21 °C 78.8% RH Safe for most occupied buildings
1.16 16.99 °C 82.8% RH Safe including pool rooms and humidified interiors
0.70 (glass only) 18.18 °C 89.3% RH Passive-house glass; frame edge becomes the weak point
Where condensation actually forms: not at glass centre but at the glass edge, where the aluminum spacer bridges the cavity. The θsi rows above are whole-window averages; the spacer line runs 3–5 °C colder. Warm-edge spacers exist for exactly this failure, which is why we default to them on every Low-E argon build even though they add only $2–4/m².

Double Glazed Aluminium Windows: Specification Lines to Fix in the PI

For the glazing-cost side (double vs triple per W/K) see our double glazed and triple glazing cost analysis.

Casement Windows with Screens: Free Area, Not Just Mesh

Screens are quoted as an accessory and evaluated as an afterthought, then blamed for “the window does not ventilate”. The physics: a standard fiberglass 18×16 mesh with 0.23 mm wire has 71.4% open area. A 600×1400 mm sash presents 0.84 m² of openable area; behind the screen that drops to 0.60 m² of free area — a 29% ventilation cut before the insect pressure starts.

Mesh (per inch) Wire dia. (mm) Open area Free area of a 0.84 m² sash Typical use
18×16 fiberglass 0.23 71.4% 0.601 m² Standard residential, mosquito pressure
16×16 fiberglass 0.25 72.3% 0.607 m² Coarser, better airflow, lets pollen through
20×20 polyester 0.20 72.3% 0.607 m² Pet-resistant blends, higher tensile
Stainless 12×12 0.35 73.5% 0.618 m² Security screening, heavier (0.9 kg/m²)

Screen Frame Options and What They Cost

Fixed-frame screens (clip into the sash) cost 6–8 USD/m² and take 10 minutes to fit, but they occupy the sash and must be removed to clean glass. Roller (retractable) screens cost 10–14 USD/m², hide when not needed, and fail at the cassette spring after 3–5 years in dusty sites. Plisse (pleated) screens run 16–22 USD/m² and are the only option that works on oversize casement sashes where a roller cassette exceeds the frame depth. For casements specifically, the screen must sit on the exterior side of the sash (outswing) or interior side (inswing) — confirm which, because the screen frame profile is mirrored and cannot be swapped after order.

The Free-Area Rule We Apply

When a client specifies “natural ventilation” for a room, we size openable area against the screen-degraded number, not the sash area: bedroom 5% of floor area free, living 10%. A 12 m² bedroom needs 0.6 m² of screened free area — one 600×1400 sash exactly meets it, two would oversize the order by 40%. This rule has killed more over-ordering on Latin American residential projects than any price negotiation.

Casement Windows to the Australian Standard (AS 2047 / AS 4055)

Australia is the market where casement specifications are most codified, and Chinese factories win or lose on whether they can produce the test file. The chain runs: site wind classification per AS 4055 (housing) or AS 1170.2 (other buildings) → window design pressure → testing per AS 2047 with AS 4420 methods → glass selection per AS 1288.

AS 4055 wind class Regional wind speed (m/s) q = 0.6V² (kPa) Structural test at 1.5× (kPa) Typical exposure
N1 34 0.69 1.04 Sheltered inland sites
N2 40 0.96 1.44 Most suburban housing
N3 45 1.22 1.82 Open terrain, hills
N4 50 1.50 2.25 Exposed coastal
N5 55 1.82 2.72 Exposed coastal, topographic lift
N6 / C1 60 2.16 3.23 Severe exposure; cyclonic needs debris screen

What Australian Certifiers Ask For

The Two Frequent Rejections

First, reports from non-ILAC labs are simply not accepted; a factory that quotes “AS 2047 tested” should name the lab and the report number. Second, cyclonic regions (C classes) require debris-impact screening of the whole window assembly, which changes glass to laminated and adds screen/track reinforcement — quoting an N-class unit into a C-class site is the classic error. We map every Australian RFQ to a wind class from the site address before quoting, and we publish the same logic in our aluminium doors and windows AS 2047 data overview.

The Top 10 Spec Lines We Compare on Every RFQ

Ten lines cover 95% of the price and performance spread between a factory quote that works and one that does not. We score every incoming quote against this sheet; two quotes that differ by 30% in price are almost always separated by lines 2, 5 and 9, not by margin.

Lines 1–5: The Performance Core

# Spec line What to demand in writing Cost spread it hides
1 Profile series and wall thickness Section drawing with wall called out per member (1.4/1.8/2.0 mm) 8–14 USD/m²
2 Thermal break strip width 14 / 24 / 34 mm PA66 GF25, strip brand and pour/bridge process 6–15 USD/m²
3 Glazing makeup Digits: 4-16-4, Low-E coat position, argon %, cavity mm 15–45 USD/m²
4 Spacer type Warm edge vs aluminum; psi value declared 2–4 USD/m²
5 Hardware brand, stay length, screw schedule Brand tier, stay 250–400 mm, screws per stay and wall thickness basis 12–25 USD/m²

Lines 6–10: The Project-Risk Core

# Spec line What to demand in writing Cost spread it hides
6 Design wind pressure and test standard kPa + standard (EN 12210 class / NAFS PG / AS 2047 class) quote validity, not just price
7 Screen type and free area Mesh spec, frame type, fixed/roller, interior or exterior side 6–22 USD/m²
8 Finish RAL code, polyester vs PVDF, film 60–80 µm, salt-spray hours 3–14 USD/m²
9 Drainage detail Weephole size and count per mullion, sill cap, pressure-equalized cavity 0–6 USD/m²
10 Packing and labelling Per-opening carton labels, foam corners, crate vs loose cartons 2–5 USD/m²

Lines 1–5 are the performance core (Sections 2–4 of this article). Lines 6–10 are the project-risk core: a cheap quote with no declared test standard is not a price advantage, it is a different product. For a worked example of how these lines move a landed cost, see the Guadalajara case in Section 11.

FOB Pricing: Series, Size Effect and Option Uplifts

Casement window cost is perimeter-driven: the frame is bought by the metre and the glass by the square metre, so price per m² falls as openings grow. The model below prices a 70-series frame (24 mm thermal break, 2.0 mm wall) with 4-16-4 Low-E argon at a 26 USD/m fabricated frame rate, 34 USD/m² glass rate, plus 18 USD/unit of hardware and labour:

Size Effect: Price per m² Falls as Openings Grow

Opening (W×H, m) Area (m²) Frame perimeter (m) Cost per unit (USD) Cost per m² (USD)
0.6×0.9 0.54 3.00 110 204
0.9×1.2 1.08 4.20 156 144
1.2×1.5 1.80 5.40 206 115
1.5×1.8 2.70 6.60 261 97
2.4×1.5 (2 sashes) 3.60 7.80 316 88

Same product, 2.3× price per m² between the smallest and largest opening. Any factory quote given as a single $/m² number without size classes is either averaged across your bill of sizes (fine) or quoting the largest size (optimistic). Send the actual schedule of sizes; a 40-opening project quotes 12–18% lower per m² than a 6-opening one at identical specification because fixed costs spread.

Option Uplifts (added to the base build)

Option Uplift (USD/m² unless noted) Note
Tempered glass (both panes) 5–8 Mandatory above 1.5 m² in most codes
Laminated 6.38 PVB 12–16 Fall safety, sound, cyclonic debris
Triple glazing (4-12-4-12-4) 35–45 Adds 9–12 kg/sash; hardware class up
Argon fill 4–6 vs air at same cavity
Warm-edge spacer 2–4 Default on our Low-E builds
Fixed-frame insect screen 6–8 Fiberglass 18×16
Roller (retractable) screen 10–14 Cassette in frame head
PVDF coating (vs polyester) 8–14 Coastal / high-UV
Custom RAL (non-stock) 3–5 Stock RAL 9016/7016 no charge
Limit arm / restrictor 3–6 per sash Wind-season hardware insurance
Premarco (sub-frame) 8–12 per m perimeter Changes installation detail
Budget planning: a 120 m² house window package in 70 series, 24 mm break, Low-E argon double glazing, screens included, lands in the $13,000–17,000 FOB band at typical size mixes — about $110–140/m². The same package in 90 series triple glazing runs $21,000–26,000. The delta is real thermal performance (Uw 1.16 vs 1.58) but only pays back in heating or cooling-dominated climates; ask for the degree-day math before upsizing the spec.

Certification Path: Which File Goes With Which Market

Chinese casement windows ship with four families of documentation. Getting the right family before the PO is cheaper than retrofitting: test bodies quote 3–5 week lead times and $4,000–18,000 per family, and the paperwork attaches to a tested configuration, not to whatever the factory builds that month.

The Documentation Families by Market

Market Framework What must be declared Typical cost & lead time
European Union CE per EN 14351-1 (DoP, AVCP system 3) Uw, air EN 12207 class, water EN 12208 class, wind EN 12210 class, danger of glass, release of Cd/Pb $4,000–8,000 per family; 3–4 weeks
North America NFRC 100/200 rating + NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) U-factor and SHGC (NFRC), Performance Grade PG in psf (structural test at 1.5× DP; water at 15% DP for R class) $6,000–12,000; 4–6 weeks
Florida / HVHZ Miami-Dade NOA or Florida Product Approval (TAS 201/202/203) Large/small missile impact, cyclic pressure, water $10,000–18,000; 8–16 weeks
Australia AS 2047 + AS 1288 (+ WERS for energy) Wind class test file, glass schedule, installation compliance $5,000–10,000 per class; 4–6 weeks
China export baseline GB/T 8478 Grade sheets: air, water, wind, sound, thermal Factory-held; free with RFQ

Certificate Gaps That Cost Money Later

How these classes map onto a sliding-system sister product is covered in our GB/T 8478 and EN 12210 window spec data article.

Installation: 8 Steps and the 3 Points That Leak

Casement water failures are installation failures in about 80% of warranty claims we process. The factory-side sequence below assumes a masonry opening with premarco; the three failure points that follow account for nearly every claim.

Step Operation Specification / tolerance
1 Check opening dimensions Width/height +10 / +5 mm vs premarco; diagonal ≤ 3 mm
2 Fix premarco (if specified) Anchors every 500 mm, ≥100 mm from corners; laser level ≤ 1 mm/m
3 Set window into premarco Shim at hinge line and lock points only; never at mid-span
4 Anchor the frame Ø6–8 screw anchors every 450–600 mm; no plastic plugs in hollow block
5 Seal perimeter stage 1 Backer rod + MS polymer joint 8–12 mm; never fill full depth with foam
6 Flashing / sill detail Sill flashing lapped ≥50 mm over frame upstand; end dams 20 mm
7 Interior seal stage 2 Acoustic sealant interior; vapor-tight inside, vapor-open outside
8 Commissioning Open/close 5 cycles per sash; water hose test on 10% of units; weepholes clear

The Three Failure Points

Adjustment on Site

Friction stays carry an eccentric adjustment: turn the stay cam screw to move the sash 1–2 mm toward or away from the frame. A sash that rattles in wind is under-compressed (turn +), a sash that takes two hands to lock is over-compressed and will chew the gasket in one season. Target: even drag when opening, gasket compression 3–4 mm visible on the seal line, and no daylight between sash and frame at the lock side when closed.

Case Data: 96 Casement Windows to Guadalajara, Mexico

A 42-unit residential building, 96 units of 1,200×1,500 mm casement (two 600 mm sashes each), 70 series, 24 mm thermal break, 4-16-4 Low-E argon, warm-edge spacers, fixed-frame screens on bedroom units. Total glazed area 172.8 m². The client benchmarked a local fabricator at 262 USD/m² installed-materials.

Landed Cost Stack vs the Local Fabricator

Cost line Amount (USD) Per m² (USD)
FOB China (172.8 m² at 142 USD/m²) 24,538 142.0
Ocean freight, 20′ GP to Manzanillo 1,650 9.5
Marine insurance (0.4%) 105 0.6
Import duty (15% on CIF, tariff line 7610.10 — confirm with broker) 3,944 22.8
Customs brokerage and documents 480 2.8
Inland transport to Guadalajara site 720 4.2
Landed, delivered 31,437 181.9

Against the local benchmark of 262 USD/m², the imported package saved 80 USD/m² — 30.6% — before installation, which was contracted locally at the same rate either way. The duty line is the largest controllable variable; at a 5% tariff the saving reaches 40%, so the tariff check is worth a broker call before the PO, not after.

Schedule and Inspection Results

Milestone Duration Cumulative (days)
Shop drawing approval (top-view handing elevations) 5 5
Profile extrusion + powder coating 12 17
IGU fabrication (glass, spacer, argon) 4 21
Machining, hardware assembly, QC 3 24
Packing and container loading 2 26
Ocean to Manzanillo 30 56
Customs clearance + inland 7 63

Arrival QC: 94 of 96 units passed on visual and hardware check. One unit had a glass scratch (replaced by local glazier, 210 USD credited), one had a paint rub on a sill cap (field-repaired with touch-up). On-site hose testing on 10% of units found one jamb leak traced to the premarco substitution detail, corrected with MS polymer and a revised end-dam detail for the remaining 42 openings. Site defect rate across the batch: 2.1% by unit, 0.0% structural.

MOQ, Packing and Container Math

Our MOQ for mixed-size casement orders is 30 m² or 20 units. Below that, setup costs (die changes, glazing line stops, hardware kits) push the effective price 15–25% higher — small orders are quoted honestly but they are a different product economically.

What Actually Fits a Container

Parameter Value
Packed carton, 1,200×1,500 unit 1.28 × 1.58 × 0.12 m = 0.243 m²³
Unit weight (70 series, double glazed) 35 kg
40′ HQ capacity (76 m³) 313 units by volume / 743 by weight → volume-limited
Freight per unit at $2,800/40′ HQ 8.94 USD/unit = 4.97 USD/m²
Triple-glazed variant 41 kg/unit → still volume-limited at 634 units
LCL minimum 5 m³, crated in 5-ply plywood at 45 USD/m³

Payment, Inspection and Lead Time

RFQ Checklist: 8 Data Points and 6 Questions

Send these eight items with any ventanas de aluminio request and quotes come back comparable in 48 hours instead of ten days of back-and-forth:

Eight Data Points That Make Quotes Comparable

And the six questions that separate a system factory from a workshop:

Six Questions That Filter the Factory

Bring the answers to the top-10 sheet in Section 7 and the decision writes itself. For the sliding counterpart to this casement analysis, see our aluminum sliding window frame and performance data, the Spanish-market CTE analysis in ventanas de aluminio y cristal with CTE Uw data, and the category overview at ROGENILAN casement windows. Quote requests with the schedule of openings go to our RFQ desk with a 48-hour turnaround on a fully specified 70-series casement package.

[footer_contact_form]