French buyers searching fentres en aluminium are usually replacing single-glazed timber joinery in an existing wall opening, not fitting a new-build window. That single fact drives every specification decision: the frame has to fit a measured tableau (structural opening) with a 10 mm installation gap, the sash weight has to suit the existing reveal depth, and the finished unit has to carry CE marking under EN 14351-1 with a Declaration of Performance before it can be sold in France. This page sets out the extrusion grades, glazing builds, sliding hardware, French opening sizes, performance classes, FOB price bands and retrofit installation tolerances used by Chinese aluminium window factories supplying French distributors and installers.

FOB price
$118-198 /m2

Uw, double
1.3-1.6 W/m2K

Profile wall
1.4-2.0 mm

MOQ
30 m2 / colour

Lead time
30-40 days

Contents
1. Order sheet terminology
2. Aluminium sliding windows
3. Double glazed builds and Uw
4. Triple glazing weight limits
5. Extrusion and coating data
6. French opening sizes and metré
7. CE marking and AEV classes
8. FOB price tables
9. MOQ, payment, lead time
10. Retrofit installation
11. Landed cost case
12. RFQ checklist

Fentres en Aluminium: What a French Order Sheet Actually Specifies

A quotation request written in French rarely names a product the way an English catalogue does. The buyer sends a measured opening, a colour reference and a performance class, and expects the factory to translate that into a bill of materials. Five terms account for most of the price differences between two quotes for what looks like the same window.

Dormant, Ouvrant, Tapee and the Four Other Terms That Move the Price

French term English equivalent Where it sits on the drawing Typical price effect
Dormant Outer frame / fixed frame Anchored into the tableau Base cost, priced by perimeter
Ouvrant Opening sash Inside the dormant, carries the glass +18-30% per opening leaf
Tapee Reveal cover / facing trim Clips over the gap between frame and wall +$6-11 per metre
Parclose Glazing bead Holds the sealed unit in the sash Included, differs by depth
Rejingot Upstand at the sill (door thresholds) Below the door leaf Aluminium sill +$18-34 per unit
Cremone Multi-point espagnolette lock Sash edge, handle side +$9-16 per sash
Seuil Threshold / sill profile Bottom of door units +$14-28 per metre

The tapee detail is the one that surprises first-time buyers. French renovation work normally keeps the existing plaster return, so the new frame is set back 30-60 mm from the wall face and a 30 mm aluminium facing covers the joint. A factory that quotes without tapee delivers a frame that sits flush and leaves the plasterer to bridge a 40 mm gap with sealant, which fails at the first driving-rain test.

Why the Spelling Fentres Still Produces Quotations

The accented spelling fenetres and the unaccented fentres are the same product. Search terms typed on phones drop the circumflex, and B2B enquiries copied from older purchase orders drop it as well. Factories that only match the accented form lose the enquiry, so both spellings are quoted against the same profile family. What matters commercially is the profile series and the glazing build behind the word, not the diacritic.

Quote check: ask for the price per square metre of frame and the price per linear metre of tapee, sill and shutter box separately. A single lump-sum figure per unit hides the 30-40% spread that exists between a 70 mm and a 90 mm series on the same opening.

Aluminium Sliding Windows: Track Count, Sash Weight and Clear Opening

Sliding units dominate French renovation for one reason: the leaf travels inside the frame plane, so the window needs no swing clearance into the room. The trade-off is that only part of the opening can ever be open at once, and the overlap between leaves reduces the clear opening further. The numbers below are the ones used to size a unit before it is quoted; the wider hardware detail sits in our aluminium sliding window specification page.

Two, Three or Four Tracks: Clear Opening Arithmetic

A two-track unit with two equal leaves gives a clear opening of roughly 46-48% of the frame width. Three tracks with three leaves gives 62-66%. The calculation is not half the width: two leaves must overlap by at least one stile width plus a 6 mm air gap, and the interlock adds another 22-28 mm per pair.

Configuration Frame width Leaf width Clear opening Ratio
2 track / 2 leaf 1800 mm 925 mm 845 mm 47%
2 track / 2 leaf 2400 mm 1225 mm 1145 mm 48%
3 track / 3 leaf 2400 mm 820 mm 1520 mm 63%
3 track / 3 leaf 3000 mm 1020 mm 1920 mm 64%
4 track / 4 leaf 3600 mm 915 mm 2410 mm 67%
2 track / 1 fixed + 1 slide 2100 mm 1050 mm 985 mm 47%

For a habitable room in French residential work, the clear opening must also satisfy the escape route rule in the local safety code: a free width of 600 mm and a free height of 1000 mm, with the unobstructed area no less than 0.35 m2. A 1800 mm two-leaf unit passes at 845 x 1300 mm; a 1500 mm unit fails on width and has to be re-specified.

Roller Assemblies Rated by Sash Weight

Sliding failures in the field are almost always roller failures. The nylon wheel that costs $0.40 carries about 40 kg and starts flat-spotting after 8,000 cycles. Stainless 608 bearings with a polyamide tyre carry 110 kg and hold their roundness past 25,000 cycles, which at two openings a day is 34 years of service.

Roller type Rated load per pair Cycle life Sash weight ceiling Adders per unit
Nylon wheel, plain bore 40 kg 8,000 Up to 35 kg Included
Nylon wheel, steel axle 60 kg 12,000 Up to 55 kg Included
POM wheel, 608 bearing 90 kg 20,000 Up to 80 kg +$4
Stainless 608, polyamide tyre 110 kg 25,000 Up to 100 kg +$7
Tandem stainless, 2×608 160 kg 30,000 Up to 150 kg +$12

Drainage and Brush Seals That Pass EN 12208 Class 9A

Class 9A means no water penetration at 600 Pa test pressure, which is roughly a 40 m/s driving rain. Three details decide whether a given unit reaches it: a 5-8 degree fall on the bottom track, a 30 mm2 spill slot every 500 mm, and an equalising chamber between the inner and outer track that lets pressure build on both sides of the seal. Units with a flat bottom track and no chamber stall at class 5A (300 Pa) regardless of how much sealant is applied on site.

Detail Class 5A build (300 Pa) Class 9A build (600 Pa)
Bottom track fall 0-2 degrees 5-8 degrees
Spill slots 2 per leaf 1 per 500 mm, 30 mm2 each
Equalising chamber None Baffled, 12 mm minimum
Brush seal Single, 5 mm pile Double, 7 mm pile + fin
Corner welds 2-point 3-point with corner gasket

Double Glazed Aluminium Windows: Glass Builds and Calculated Uw

The Uw figure on a quote is the whole-window value, not the centre-of-glass Ug. A unit with Ug 1.1 W/m2K can still deliver Uw 1.6 if the frame is a 60 mm non-thermal-break profile with an aluminium spacer. French thermal regulation assesses the window, so the frame and the edge detail matter as much as the glass.

Five Glass Builds With Their Uw, SHGC and Rw Values

Glass build Ug W/m2K Uw in 70 mm break frame SHGC Rw (C;Ctr) Adder /m2
4-16A-4 clear 2.7 2.9-3.1 0.76 30 (-1;-4) Base
4-20A-4 low-E 1.4 1.6 0.55 31 (-1;-4) +$9
4-24A-4 low-E argon 1.1 1.3-1.4 0.52 32 (-1;-4) +$14
6-18A-6 laminated in / low-E out 1.2 1.4 0.48 35 (-1;-5) +$27
4-14A-4-14A-4 low-E argon triple 0.6 0.9-1.0 0.42 34 (-2;-7) +$46

The 6 mm laminated inner pane is the standard answer for ground-floor and balcony doors in France: it holds together after breakage and satisfies the safety glazing rule without a visible film. It also lifts Rw by 3 to 4 dB because the 0.76 mm PVB interlayer damps the coincidence dip.

Warm-Edge Spacers and the Condensation Margin

The inner surface temperature at the glass edge decides whether a window fogs on a January morning. Aluminium spacers conduct, dropping the edge temperature 2.5-3.5 K below the centre of glass. A hybrid or butyl warm-edge spacer cuts that to 1.0-1.5 K. In a 20 degrees C room at 50% relative humidity the dew point is 9.3 degrees C, so the difference decides whether the edge stays clear or runs water.

Spacer type Linear thermal transmittance Edge temp at -5 degrees C outside Condensation at 20/50%
Aluminium box, 12 mm 0.08 W/mK 10.1 degrees C Marginal, fogs at 60% RH
Aluminium box, 8 mm 0.08 W/mK 9.8 degrees C Fogs at 55% RH
Stainless steel, 12 mm 0.045 W/mK 11.9 degrees C Clear to 65% RH
Hybrid warm-edge 0.032 W/mK 13.2 degrees C Clear to 72% RH
Butyl secondary seal + warm-edge 0.028 W/mK 13.8 degrees C Clear to 75% RH

Argon Retention and Edge Seal Testing

Argon fill loses its benefit if the edge seal allows gas migration. The measurable test is the initial concentration after 24 hours: a two-component polysulphide seal with a butyl primary typically holds 92-95% argon; a silicone seal with the same primary holds 88-91%. EN 1279-3 requires the gas loss to stay under 1 percentage point per year, and a factory claim without a batch test record is not evidence. Ask for the EN 1279-2, -3 and -5 test report numbers, and check that the reported date is inside the last three years.

Triple Glazed Aluminium Windows: Weight, Frame Depth and Hinge Load

Triple glazing adds thermal performance and adds mass. A 44 mm triple unit weighs 30-32 kg per square metre against 20-22 kg for a 24 mm double unit, and the extra 10 kg per square metre lands directly on the hinges, the sash profile and the frame anchorage. Whether the upgrade is worth quoting depends on the opening size and the wall depth available.

Weight per Square Metre by Glass Build

Build Total thickness Weight /m2 Max sash 800 mm wide Max sash 1200 mm wide
4-16A-4 24 mm 20 kg 1,450 mm high 1,250 mm high
4-24A-4 32 mm 20 kg 1,450 mm high 1,250 mm high
6-18A-6 laminated 30 mm 30 kg 1,350 mm high 1,150 mm high
4-14A-4-14A-4 44 mm 30 kg 1,300 mm high 1,100 mm high
6-14A-4-14A-6 laminated triple 50 mm 40 kg 1,150 mm high 950 mm high

Those heights assume two hinges on a casement and a 3 mm/m maximum deflection. A 1,300 mm wide, 1,600 mm high triple-glazed sash weighs 66 kg and needs a third hinge plus a reinforced corner cleat; quoting it as a standard sash guarantees the bottom corner drops within a year.

Frame Depth 70, 80 and 90 mm: What Fits

Series Frame depth Max glass thickness Uw with low-E double Uw with triple Price level
70 mm 70 mm 36 mm 1.4-1.6 Not advisable Lowest
80 mm 80 mm 48 mm 1.3-1.4 1.0-1.1 Mid
90 mm 90 mm 54 mm 1.2-1.3 0.9-1.0 High
Passive 100 mm 100 mm 60 mm 1.1 0.8 Highest

A 70 mm series physically accepts a 36 mm unit, and some factories will sell a 44 mm triple in it by reducing the glazing bead to 3 mm. That bead will bow under wind load and the unit loses its EN 1279 warranty. If the project calls for triple glazing, specify 80 mm or deeper from the start.

Cost Delta and Heating-Saving Payback

Item Double low-E argon Triple low-E argon Delta
FOB price /m2 $146 $192 +$46
Sash and hinge upgrade Included +$11 /m2 +$11
Annual heat loss, 18 m2 flat 1,180 kWh 790 kWh -390 kWh
Annual saving at $0.24/kWh – $94 $94
Simple payback – 11.0 years 11.0 years

Eleven years is the honest figure for a temperate French climate with gas heating. It shortens to 7-8 years where electricity is the heat source, and it lengthens past 15 years in a mild coastal zone where heating demand is low. Selling triple glazing on comfort and acoustic grounds is defensible; selling it on payback alone is not.

Extrusion, Thermal Break and Coating Parameters

Two factories can quote the same 70 mm series and deliver different products. The differences sit in alloy temper, wall thickness at the screw bosses, break width and coating thickness. These are the values to put in the purchase order.

Alloy Temper and Mechanical Values

Alloy / temper Tensile strength Rm Yield Rp0.2 Elongation Typical use
6063-T5 160 MPa min 110 MPa min 8% Standard frames, sashes
6063-T6 205 MPa min 180 MPa min 8% Large sashes, structural mullions
6060-T66 215 MPa min 160 MPa min 8% Thin-wall profiles, tight tolerance
6005A-T6 270 MPa min 225 MPa min 8% Curtain wall, long spans
6061-T6 290 MPa min 240 MPa min 10% Reinforcement, brackets

Wall thickness is measured on the load-bearing face, not on the decorative cover. GB/T 8478 sets 1.4 mm minimum for the main profile; the French CSTB assessment for most exported series assumes 1.5 mm on the frame and 1.4 mm on the sash. Anything advertised at 1.2 mm is a light commercial grade and should not be quoted into a residential tender.

Polyamide Break Width, Crimping and Pour-and-Debridge

The thermal break is a 25% glass-fibre reinforced polyamide strip, either crimped (mechanical) or pour-and-debridge (polyurethane). Crimped strips are 14.8, 20, 24 or 34 mm wide. The width drives Uf: a 24 mm strip in a 70 mm frame gives Uf 2.6 W/m2K, a 34 mm strip in a 90 mm frame gives 1.9 W/m2K. Crimping pressure matters more than width when the strip is under-delivered: knurled teeth that are not fully rolled leave a 0.15 mm gap that shows up as a 0.4 W/m2K penalty in the hot-box test.

Break type Strip width Uf in 70 mm frame Shear strength Notes
Crimped PA66-GF25 14.8 mm 3.2 W/m2K 28 N/mm Entry series only
Crimped PA66-GF25 24 mm 2.6 W/m2K 32 N/mm Standard export
Crimped PA66-GF25 34 mm 2.0 W/m2K 32 N/mm 80-90 mm series
Pour-and-debridge PU 20 mm 2.9 W/m2K 24 N/mm Smooth interior face
Pour-and-debridge PU 30 mm 2.2 W/m2K 24 N/mm Higher tooling cost

Powder, Anodizing and Salt-Spray Data

Finish Thickness Pre-treatment Salt spray, neutral Salt spray, acetic
Polyester powder, Qualicoat class 1 60-80 um Chrome-free conversion 1,000 h 500 h
Polyester powder, Qualicoat class 2 80-120 um Chrome-free + primer 1,500 h 750 h
Anodizing class 15 15 um Etch + desmut 1,000 h Not applicable
Anodizing class 20 20 um Etch + desmut 1,500 h Not applicable
PVDF fluoropolymer 25-35 um Primer + topcoat 2,000 h 1,000 h
Sublimation wood grain 70-90 um Powder base + transfer 1,000 h 500 h

Coastal projects within 1 km of the sea should be quoted at Qualicoat class 2 or anodizing class 20, and the fixing screws should be A2 stainless rather than zinc-plated. Mixing a class 2 finish with plated screws produces rust streaks at every fixing point within two winters, and the complaint lands on the window supplier regardless of who specified the screws.

French Opening Sizes and the Metre Before the Order

French renovation stock sizes are not the same as the metric rounds used in Germany or the imperial sizes used in the UK. A distributor who quotes from a generic price list discovers at survey that half the openings fall outside the standard band and the order needs a re-quote. The table below lists the sizes that account for most of the volume in French residential replacement work.

Standard French Opening Sizes and What They Imply

Tableau (structural opening) Typical unit Leaves Frame size ordered Glass width per leaf
2150 x 1350 mm Porte-fenetre, living room 2 sliding or 2 casement 2130 x 1330 mm 605 mm
2150 x 1205 mm Porte-fenetre, bedroom 1 fixed + 1 slide 2130 x 1185 mm 545 mm
1450 x 1350 mm Bedroom window 2 casement 1430 x 1330 mm 655 mm
1350 x 1350 mm Bedroom or kitchen 2 casement 1330 x 1330 mm 605 mm
1200 x 1200 mm Bathroom, utility 1 casement + 1 fixed 1180 x 1180 mm 530 mm
1000 x 1000 mm Small room, WC 1 casement 980 x 980 mm 890 mm
600 x 600 mm Bathroom, cellar 1 top-hung 580 x 580 mm 490 mm

The frame is ordered 20 mm smaller than the tableau on each dimension for a standard 10 mm joint per side. That gap is not wasted: it takes the foam backer rod, the low-expansion PU and the tapee cover. On a renovation where the old frame is removed down to the masonry, the same 20 mm deduction applies but the joint is closed with a 30 mm tapee instead of plaster.

Measuring a Renovation Opening: Three Readings and a Tolerance Stack

One measurement per dimension is not a survey. Take width at the top, middle and bottom of the reveal and height at the left, middle and right, then use the smallest width and the smallest height. Old masonry openings are rarely square: a 6 mm out-of-square over 2,150 mm is normal, and a frame forced into it will not close on the handle side.

Tolerance item Allowance Consequence if ignored
Joint per side, plastered reveal 10 mm Frame will not enter, or plaster cracks
Joint per side, tiled reveal 7 mm Tile edge chips during insertion
Out-of-square 5 mm/m max Sash rubs, espagnolette misaligns
Reveal twist 4 mm max Visible gap at one corner
Sill level difference L/R 3 mm max Water ponds on the bottom track
Wall thickness variation 10 mm Tapee cannot cover the joint
Frame plumb after fixing 2 mm/m Sliding leaf drifts open

Tapée, Rejingot and Roller Shutter Box Interfaces

A roller shutter box changes the head detail, not the frame. The box sits either inside the reveal above the frame (boxe tunnel) or on the room side (boxe apparente). A tunnel box needs 180-220 mm of head height and a frame with a 20 mm head extension; a surface box needs no frame change but reduces the daylight height by the box depth.

Reveal depth Shutter box option Head loss Frame change
Under 100 mm No box, external shutter only 0 mm None
100-140 mm Surface box 165 mm 165 mm internal None
140-180 mm Tunnel box 180 mm 0 mm Head extension +20 mm
180-240 mm Tunnel box 220 mm with insulation 0 mm Head extension +20 mm
Over 240 mm Tunnel box + independent lintel insulation 0 mm Head extension +35 mm
Survey rule: photograph the reveal with a tape in frame at all four corners. A 40 mm discrepancy between the drawing and the site is common in buildings older than 1960, and the factory cannot absorb it after extrusion.

CE Marking, AEV Classes and the Documents a French Buyer Checks

An aluminium window sold into France needs a Declaration of Performance under EN 14351-1, a CE mark on the product or its packaging, and a technical file that supports every declared value. Distributors are the ones exposed if the file is incomplete, because the importer carries the manufacturer obligation.

CE Marking and the Declaration of Performance

The DoP lists the essential characteristics with the achieved class or value: thermal transmittance, air permeability, watertightness, wind resistance, acoustic performance, impact resistance where relevant, and dangerous substances. A DoP that states only “Uw 1.4 W/m2K” and leaves the other rows blank is not a valid declaration. It must also carry the notified body number when the factory operates under a factory production control system audited to EN 14351-1 Annex ZA.

Characteristic Standard Class or value to declare Typical export series
Air permeability EN 12207 Class 4 (600 Pa) 70-90 mm casement and sliding
Watertightness EN 12208 Class 9A (600 Pa) 80-90 mm with equalised drainage
Wind resistance EN 12210 Class 4 / C4 (2,000 Pa) 90 mm, 1.6 mm wall
Wind resistance, high rise EN 12210 Class 5 / C5 (2,400 Pa) 90 mm with steel reinforcement
Thermal transmittance EN ISO 10077-1 Uw 1.3-1.6 W/m2K Double low-E argon
Acoustic EN ISO 717-1 Rw + Ctr 32-35 dB Asymmetric or laminated build
Impact resistance EN 13049 Class 3 where required Ground floor and doors
Dangerous substances EN 14351-1 Pass All series

AEV Classification in French Tenders

French tenders describe performance in the AEV shorthand: A for air, E for water (eau), V for wind (vent). The string A*4 E*7A V*C2 is a common residential requirement; A*4 E*9A V*C4 appears on exposed coastal sites. The figures after the star are the class numbers, and the letter after that is the deflection class for wind. A unit rated E*7A passes 450 Pa but not 600 Pa, so it cannot be substituted for an E*9A unit without a written derogation.

AEV string Air Water Wind Where it is specified
A*3 E*5A V*C1 Class 3 Class 5A (300 Pa) Class 1 Sheltered inland, low rise
A*4 E*7A V*C2 Class 4 Class 7A (450 Pa) Class 2 Standard residential
A*4 E*9A V*C3 Class 4 Class 9A (600 Pa) Class 3 Exposed facade, 3-8 storeys
A*4 E*9A V*C4 Class 4 Class 9A (600 Pa) Class 4 Coastal, high wind zone
A*4 E*9A V*C5 Class 4 Class 9A (600 Pa) Class 5 High rise over 28 m

Acoustic and Thermal Requirements

Acoustic requirements in French residential work are usually expressed as Rw + Ctr, not Rw alone. The Ctr term penalises low-frequency performance, which is exactly the traffic noise band. A window declared Rw 38 dB with Ctr -5 delivers 33 dB(A) against traffic; a window declared Rw 35 with Ctr -1 delivers 34. The second is the better product for a street facade and often the cheaper one.

On the thermal side, the residential requirement is a maximum Uw of 1.3 W/m2K for windows in most climate zones, tightening to 1.1 in the coldest. A 70 mm series with a 24 mm double low-E argon unit lands at 1.3-1.4 and sits on the limit; the 80 mm series lands at 1.2 and leaves margin for the frame-to-wall junction, which the calculation does not include.

FOB Price Tables for Aluminium Windows from China

The bands below are FOB Foshan for orders of 100-300 m2, powder coated in a standard RAL colour, with hardware, glazing and factory assembly included. They exclude freight, insurance, French import VAT and installation. Prices move with aluminium ingot and with the glass index, so treat them as a range for budgeting and confirm at order.

FOB Price per Square Metre by Series

Series Glazing Uw FOB /m2 Frame + sash only Assembled and glazed
70 mm casement 4-20A-4 low-E 1.6 $118-132 $96 $118
70 mm sliding 4-20A-4 low-E 1.7 $126-140 $102 $126
80 mm casement 4-24A-4 low-E argon 1.3 $142-158 $118 $142
80 mm sliding 4-24A-4 low-E argon 1.4 $148-164 $124 $148
90 mm casement 6-18A-6 laminated 1.2 $168-186 $140 $168
90 mm sliding, 3 track 4-24A-4 low-E argon 1.3 $176-198 $148 $176
80 mm tilt-turn 4-24A-4 low-E argon 1.3 $164-182 $136 $164

Option Adders That Buyers Forget

Option Adder Basis Share of orders that take it
Triple glazing 44 mm +$42-48 /m2 Glass area 18%
Laminated 6 mm inner pane +$13 /m2 Glass area 35%
Qualicoat class 2 powder +$6 /m2 Frame area 22%
Anodizing class 20 +$9 /m2 Frame area 11%
Non-standard RAL colour +$4 /m2 Frame area 48%
Stainless 608 tandem rollers +$12 /unit Per sliding leaf 26%
Multi-point espagnolette +$11 /sash Per opening leaf 72%
Tapee 30 mm aluminium +$8 /m Perimeter 61%
Aluminium sill with rejingot +$22 /unit Per door 44%
Fly screen, retractable +$26 /m2 Screen area 29%
Shutter box, tunnel 180 mm +$54 /unit Per window 39%
Steel reinforcement, mullion +$7 /m Mullion length 15%

40HQ Loading Arithmetic

Freight per square metre is decided by packing density, not by the window price. A 40HQ holds about 68 m3 usable. Casement units crated knocked-down in pairs pack at 0.090 m3/m2, which gives roughly 750 m2 per container. Assembled and glazed units pack at 0.145 m3/m2, giving roughly 470 m2. The difference is $9-12 per square metre of freight, and it is the reason a knocked-down quote sometimes beats a fully assembled one even after the local assembly labour is added.

Packing mode Volume per m2 m2 per 40HQ Crating cost /m2 Freight at $2,400/FEU
Knocked-down, unglazed 0.090 m3 750 m2 $5.5 $3.20
Knocked-down, glazed 0.115 m3 590 m2 $7.0 $4.07
Assembled, unglazed 0.125 m3 540 m2 $9.0 $4.44
Assembled, glazed, corner protectors 0.145 m3 470 m2 $11.0 $5.11
Assembled, glazed, timber crate 0.165 m3 412 m2 $16.0 $5.83

MOQ, Payment and Lead Time

A French distributor ordering 40 windows in three colours is a smaller order than it looks. Colour is the constraint: powder coating runs in batches, and a 30 m2 minimum applies per colour and per finish, not per order. Splitting 120 m2 across four colours can turn a 35-day lead time into 55 days because the coating line is queued four times.

MOQ and Colour Batches

Item Minimum Notes
Order, standard colour 30 m2 One RAL, one finish
Order, custom RAL 60 m2 Powder made to order, +$4/m2
Order, wood grain sublimation 80 m2 Transfer film per batch
Per size within the order 1 unit No size MOQ if total is met
Hardware colour change 20 units Black, white, silver, bronze

Lead Time by Stage

Stage Working days What can go wrong
Drawing approval and shop drawings 3-5 Late survey data, unclear tapee detail
Extrusion and anodizing 7-10 Alloy billet shortage, die change
Powder coating 5-7 Colour batch queue, oven capacity
Cutting, machining, crimping 4-6 Break strip width substitution
Assembly and glazing 4-5 Glass delivery, spacer shortage
QC, packing, crating 2-3 Re-test after water test failure
Total, one colour 30-36 –
Total, three colours 40-48 Coating line queued three times

Packing Specification for Sea Freight

Aluminium frames arrive damaged in transit for three reasons: corner impact, abrasion between units, and compression from a crate stacked too high. The packing specification below closes all three, and it costs about $11 per square metre against a typical damage claim of 4-6% of order value.

Retrofit Installation Sequence and Tolerances

A window that tests at class 9A in the laboratory leaks on site when the installation sequence is wrong. The eight steps below are the sequence used on French renovation sites where the old frame is removed and the new unit is fixed into the masonry reveal with a tapee cover.

Step Sequence and Fixing Torque

  1. Strip the old frame and remove all timber fixings; check the reveal for loose render and repair before survey sign-off.
  2. Set the frame into the opening on 5 mm packers at the quarter points, not at the corners.
  3. Plumb and level to 2 mm/m, then tack the frame with two screws on the hinge side.
  4. Drill the remaining fixings at 150 mm from each corner and at 600 mm centres maximum.
  5. Torque the frame anchors to the value in the table below; over-torque deforms the chamber and breaks the thermal break.
  6. Fill the joint with low-expansion PU foam in two passes, then trim flush after 30 minutes.
  7. Fit the tapee or the internal seal, and seal the external joint with a low-modulus neutral silicone.
  8. Adjust the sash, check the espagnolette engagement, and run a 5-minute hose test at the sill.
Fixing Base material Hole diameter Torque Spacing
Frame anchor 7.5 mm Concrete 7.5 mm 8 Nm 600 mm
Frame anchor 7.5 mm Solid brick 7.5 mm 6 Nm 500 mm
Nylon plug + screw 8 mm Hollow brick 8 mm 4 Nm 400 mm
Chemical anchor M8 Aerated concrete 10 mm 15 Nm 400 mm
Steel bracket M8 Timber frame 9 mm 20 Nm 600 mm
Sash hinge screw Aluminium profile 4.2 mm 3 Nm Per hinge

Waterproofing at the Rejingot and the Jamb

Water reaches the frame from three directions in a French facade: driving rain on the external face, capillary rise from the sill, and condensation on the internal face. The rejingot detail handles the first two. The upstand must sit at least 25 mm above the external paving, the sill must fall 5 degrees outward, and the joint under the sill must be sealed with a pre-compressed tape rather than silicone alone, because silicone bonds to dust and detaches within three seasons.

Adjustment and Handover Checks

Check Acceptance criterion Instrument
Frame plumb 2 mm/m Spirit level, 1 m
Frame level at sill 2 mm/m Spirit level
Diagonal difference 3 mm max Tape measure
Sash clearance, hinge side 4-5 mm Feeler gauge
Espagnolette engagement All points engage without force Hand test
Sliding leaf force Under 50 N to start Spring scale
Water test at sill No ingress in 5 minutes Hose, 2 bar
Thermal imaging, optional No edge below 9 degrees C at 20/50% IR camera

Landed Cost: 42-Apartment Renovation Near Nantes

A social housing operator replaced 42 apartment windows in a 1972 concrete-frame block. The existing units were single-glazed timber casements at 2,150 x 1,350 mm with aluminium roller shutter boxes. The requirement was A*4 E*7A V*C2, Uw 1.3 W/m2K maximum, and a tapee finish because the tenants stayed in occupation during the works.

Project Configuration

Parameter Specification
Units 42 apartments, 118 windows, 1,860 m2 total
Series 80 mm casement, 24 mm polyamide break
Glazing 4-24A-4 low-E argon, warm-edge spacer
Uw achieved 1.28 W/m2K
AEV A*4 E*9A V*C3
Acoustic Rw + Ctr 33 (-1;-4) dB
Finish Qualicoat class 2, RAL 7016
Shutter boxes Tunnel 180 mm, reused existing shutters
Tapee 30 mm aluminium, matched to RAL
Delivery FOB Foshan to Le Havre, then road

Landed Cost Build-Up

Cost line Per m2 Total 1,860 m2 Share
FOB window, assembled and glazed $152 $282,720 58%
Crating and inland haulage to port $11 $20,460 4%
Ocean freight, 4 x 40HQ $5.10 $9,486 2%
Insurance, 0.4% of CIF $0.67 $1,246 0%
French import duty, 3% $5.06 $9,411 2%
Import VAT, 20%, recoverable $34.80 $64,728 13%
Port handling and customs broker $2.40 $4,464 1%
Road transport Le Havre to site $4.30 $7,998 2%
Installation labour and consumables $62 $115,320 24%
Old frame removal and disposal $8 $14,880 3%
Landed and installed, ex-VAT $268 $498,433 100%

The local French quote for the same specification came in at $512 per square metre installed, ex-VAT. The import route delivered a 48% saving, and the gap held after a 3% duty and a 20% recoverable VAT were included. Two cost lines decide whether that gap survives: the crating density, which sets the freight per square metre, and the installation labour, which is local either way.

Measured Outcome After Two Winters

Metric Before After Change
Heating demand, kWh/m2/yr 184 121 -34%
Air leakage, m3/h/m2 at 4 Pa 4.1 1.2 -71%
Internal sill temperature at -3 degrees C 6.8 degrees C 12.9 degrees C +6.1 K
Traffic noise, dB(A) in bedroom 41 33 -8 dB
Condensation complaints per winter 27 2 -93%
Warranty claims, 24 months – 0.6% of units Below 2% target

The 0.6% claim rate came from two units with a misadjusted espagnolette, both fixed on the first visit. No glass seal failures and no water ingress were recorded, which is the outcome expected when a class 9A unit is installed with a pre-compressed tape under the sill rather than a silicone bead.

RFQ Checklist and Related Product Data

A complete enquiry shortens the quotation cycle from two weeks to three days, because the factory does not have to ask for the missing data. The list below is the minimum set for an aluminium window order from China into France.

Fourteen Data Points to Send With an RFQ

  1. Opening schedule with width, height and quantity per type, measured not nominal
  2. Wall type at each opening: concrete, solid brick, hollow brick, timber frame
  3. Reveal depth and whether a roller shutter box must be integrated
  4. Required AEV string and the Uw limit from the thermal calculation
  5. Acoustic requirement as Rw + Ctr, not Rw alone
  6. Glazing preference: double, triple, laminated inner pane, solar control
  7. Series preference and acceptable frame depth
  8. Colour with RAL reference, and finish class: Qualicoat 1 or 2, anodizing 15 or 20
  9. Hardware colour and handle type, plus multi-point locking requirement
  10. Tapee, sill and rejingot scope: supplied by factory or by installer
  11. Delivery port and preferred Incoterm: FOB, CIF or DAP
  12. Target quantity per colour, to check the coating batch minimum
  13. Required documents: DoP, EN 1279 test reports, Qualicoat certificate, packing list
  14. Site programme and the date the units must be on site, not the date of order

Related Window and Door Product Data

For buyers comparing systems, the aluminium sliding window specification page covers track options and roller ratings in more detail, the double glazed window export data page sets out double and triple glazing builds with test data, and the Fenetre aluminium AEV and RE2020 page explains the AEV and RE2020 declarations that French tenders ask for. Two further pages document the Fenetres coulissantes en aluminium hardware and drainage detail, and the Fenetre en alluminium frame specs frame specification with its measured U-values.