Blog

Home   >   Doors   >   Puerta Acordeon Export from China — Aluminum Accordion Folding Door Specs & Pricing

Puerta Acordeon Export from China — Aluminum Accordion Folding Door Specs & Pricing

Puerta acordeon (aluminum accordion folding door) installed on a modern villa in China — thermal break frame with double glazing

Puerta Acordeon Export from China — Aluminum Accordion Folding Door Specs & Pricing

“Puerta acordeon” is the Spanish term for an accordion (bi-fold) door — a multi-panel system that folds back
against itself on a tracked runner to open an entire wall. ROGENILAN manufactures these systems in aluminum at its
Foshan production base and exports container loads to distributors in Spain, Mexico, France and across Latin America.
This document is written as a combined technical manual and procurement sheet: alloy grades, test data, a USD price
table, certifications, MOQ and installation steps are listed with numbers rather than marketing language.

Puerta Acordeon — Definition and How the System Works

An accordion door is built from two or more framed glass panels linked by hinges. The lead panel carries the
locking hardware; the trailing panels run on a stainless top roller and a bottom guide. When opened, the stack
compresses to roughly 10% of the opening width.

Core structure and operation

Each panel uses a 6063-T5 aluminum frame with a polyamide thermal-break strip. Panel widths run 600–1000 mm.
A six-panel 4.2 m opening stacks to about 0.45 m against the jamb. Operation force stays below 50 N with 1.0 mm
stainless top rollers.

Aluminum vs PVC vs steel frames

Aluminum carries a higher allowable span per kilogram than PVC and does not creep under UV load. Steel offers
strength but needs galvanizing and adds 40–60% weight. For openings wider than 3 m we specify aluminum only.

Puerta Plegable de Aluminio — Aluminum Profile Production

“Puerta plegable de aluminio” (aluminum folding door) is the most common Spanish-language search variant. The
production line at ROGENILAN follows a fixed material and process route.

Aluminum alloy grades

Extrusion uses 6063-T5 for standard frames and 6061-T6 for panels wider than 900 mm or heights above 2.8 m.
Tensile strength: 6063-T5 160 MPa, 6061-T6 240 MPa. Billet temper is verified by spectro-analysis on every heat.

Powder coating parameters

Coating is TGIC polyester applied at 60–80 µm after chromate pretreatment. Cure is 200 °C for 10 minutes.
Color retention is tested to 1000 hours of salt-spray (ASTM B117) with no blistering. Common RAL codes: 7016,
9005, 9016, 9010.

Thermal break strip material and width

The break uses 25 mm PA66-GF25 polyamide strip (14.6–34 mm optional). A 25 mm strip delivers a frame U-value of
2.8 W/m²K; upgrading to 34 mm with foamed cavity drops it to 1.9 W/m²K.

Accordion Doors Folding — Panel Configurations and Track Systems

“Accordion doors folding” describes the folding action itself. Configuration is selected by opening width, traffic
direction and whether a fixed pass-door is needed.

2–6 panel layouts

Two panels cover up to 1.8 m; six panels cover up to 6.0 m. Odd counts leave a fixed panel at one side. A pass-door
leaf (900 mm) is added for high-traffic commercial use without opening the full stack.

Top-hung vs bottom-rolling systems

Top-hung carries the load on the header and keeps the floor track shallow (12 mm). Bottom-rolling moves weight to
the floor and suits panels above 120 kg. For residential export we default to top-hung with a 12 mm floor channel.

Portes Pliantes — French Market Requirements

“Portes pliantes” is the French term. Buyers in France require NF mark alignment and specific hardware standards.

French market hardware requirements

French projects require a 5-point multi-lock and a handle height of 1050 mm from finished floor. Glass must be 44.2
laminated (EN 14449) for doors under 400 mm from floor. Acoustic rating target is Rw 34 dB for urban projects.

Compliance documentation

Each container ships with a Declaration of Performance (DoP) and CE marking under EN 14351-1. French distributors
also request the AEV classification (Air-Water-Wind) printed on the label. Test reports are issued by a notified body
and archived for 10 years for traceability.

Puertas Plegables — Latin American Market Notes

“Puertas plegables” is the generalized Spanish term across Mexico, Colombia and Chile. Demand centers on
hurricane-adjacent zones and warm-climate patios.

Climate and glass specification

For coastal Mexico we specify 6 mm toughened + 12 mm argon + 6 mm toughened (IGU). Solar heat gain coefficient
(SHGC) is held at 0.30–0.39. Frame color defaults to RAL 7016 anthracite.

Logistics and labeling

Spanish-language packing lists and installation manuals are printed for every LATAM container. HS code 7610.10 is
used for framed aluminum door systems.

Technical Specifications and Test Data

The table below lists the measured values from our in-house test bay and third-party labs.

Parameter Standard frame Thermal-break 25mm Hurricane-rated
Profile wall thickness 1.4 mm 1.6 mm 2.2 mm
Frame U-value 5.2 W/m²K 2.8 W/m²K 2.1 W/m²K
Wind load resistance Class C3 (1.6 kPa) Class C4 (2.0 kPa) Class C5 (2.4 kPa)
Water tightness 350 Pa 450 Pa 600 Pa
Air permeability Class 3 Class 4 Class 4
Max panel height 2.6 m 2.8 m 3.2 m

Profile wall thickness and frame dimensions

Visible frame depth is 70 mm for single-track and 115 mm for dual-track. Minimum wall thickness is 1.4 mm on
standard and 2.2 mm on hurricane-rated series verified by ultrasonic gauge on each batch.

U-value, wind load, water and air tightness

All values above are from AAMA 101 / EN 14351-1 test protocols. Country-specific wind maps are used to select the
class at quotation stage.

Price List (USD)

Prices are FOB Foshan per square meter of frame opening, ex-works, for 20 ft container orders. They exclude glass
upgrade and local freight.

Configuration Frame only ($/m²) With 5+12A+5 IGU ($/m²) MOQ
Standard single-track (1.4 mm) $78 $112 50 m²
Thermal-break 25 mm (1.6 mm) $96 $138 50 m²
Thermal-break 34 mm (1.8 mm) $108 $152 60 m²
Hurricane-rated (2.2 mm) $124 $168 80 m²

Standard single-track pricing by area

Orders above 300 m² receive a 4% volume rebate; above 800 m² a 7% rebate. Sample orders under 10 m² are
priced at 1.6× the table rate.

Premium thermal-break pricing

The 34 mm foamed-cavity option adds $12/m² over the 25 mm version and is recommended for EU and Canadian
climates where U-value limits apply.

Certifications

ROGENILAN holds the certifications required for entry into the EU, North American and Middle East distribution
channels.

CE and AAMA 101

CE marking under EN 14351-1 with published DoP. AAMA 101 / NAFS rating for the North American market with
performed-water and air infiltration results on file.

NFRC, ISO 9001, Miami-Dade NOA

NFRC label data (U-factor, SHGC, VT) is available for IGU configurations. ISO 9001:2015 quality system since 2018.
Miami-Dade NOA acceptance for the hurricane-rated series is current through the published renewal date.

Procurement Data

The following terms apply to export orders placed through the Foshan factory.

Item Standard term
MOQ 50 m² per configuration
Lead time 25–35 days after deposit and signed shop drawings
Payment 30% T/T deposit, 70% against bill of lading copy
Packaging PE foam + cardboard corner + plywood crate, 8–12 panels/crate
Container 20 ft fits ~180 m²; 40 ft HQ fits ~420 m²

MOQ and production lead time

Reorder lead time drops to 18–22 days once shop drawings are archived. Color-changeover adds 3 days per RAL code.

Payment terms and packaging specs

LC at sight is accepted above $40,000 order value. Crates are banded and marked with panel sequence numbers to
match the installation drawing.

Installation and Waterproofing

Correct installation determines the weather rating. The sequence below is the one supplied with every shipment.

Step-by-step installation

1) Set the header track level within 2 mm over the span. 2) Plumb the jamb and fix with stainless anchors at
400 mm centers. 3) Hang panels from top rollers, adjust bottom guides to 1–2 mm clearance. 4) Fit the multi-lock
and test travel. 5) Apply sealant and fit the threshold.

Waterproofing and commissioning

Use a neutral-cure silicone at all exterior joints. A 15-minute hose test at 200 mm from the frame should show no
leak at 350 Pa equivalent. Adjust rollers if operation force exceeds 50 N.

Customer Case Study

A completed residential project demonstrates the configuration math.

Project data

Location: Guadalajara, Mexico. Opening: 5.4 m × 2.6 m, 6 panels, top-hung, thermal-break 25 mm, 6+12Ar+6 IGU.
Area: 14.0 m². Delivered glass: low-SHGC solar control.

Cost comparison

Quoted at $138/m² IGU included = $1,932 FOB. A comparable US-branded system quoted $3,150 landed, a 39% saving
before freight. Payback on the thermal-break upgrade versus standard was 2.4 years via cooling-load reduction.

Configuration Comparison

The summary table supports specifiers choosing between the three frame families.

Criteria Standard Thermal-break Hurricane-rated
Best use Interior / mild climate EU / Canada / heating Coastal / storm zones
Wall thickness 1.4 mm 1.6–1.8 mm 2.2 mm
U-value 5.2 2.8–1.9 2.1
Wind class C3 C4 C5
FOB $/m² (IGU) $112 $138–$152 $168

Standard vs thermal-break vs hurricane-rated

Choose standard for budget interior partitions, thermal-break for regulated climates, hurricane-rated for
coastal wind zones. The thermal-break 25 mm is the default export specification. Lead times for all three families
follow the standard 25–35 day production schedule from the Foshan plant.

Related ROGENILAN Products

For matching systems and full category pricing, see the following pages:

[footer_contact_form]