Aluminum driveway gate with horizontal slat infill and automatic swing operator, installed at a residential entrance.
A driveway gate is a vehicular access barrier spanning a private or commercial entrance, hung on posts or running on a track. In China the export build is a 6063-T5 aluminum extrusion frame with slat, louvre, tube or solid infill, finished by powder coat or anodizing and optionally driven by an automatic operator. This article documents the geometry selection, operator sizing, alloy and coating parameters, wind and deflection data, certification set, FOB price tables, procurement terms, installation sequence and delivered project cost for aluminum driveway gates produced in China, with USD figures and side-by-side configuration comparisons.
Driveway Gate Types — Span, Leaf Count and Running Clearance
Gate type follows the clear opening, the side room available and the driveway gradient. Pick the type from the span first, then check that the site can physically accommodate the run or swing arc.
Span-to-Type Selection Table
Clear opening
Gate type
Leaves
Side run required
Drive unit
2.5–4.0 m
Single swing
1
None (swing arc)
Articulated arm / hydraulic ram
4.0–7.0 m
Double swing
2
None (swing arc)
2 × ram or underground
4.0–8.0 m
Sliding on track
1
Opening × 1.05 + 0.3 m
Rack-and-pinion drive
5.0–12.0 m
Cantilever sliding
1
Opening × 0.55 tail + 1.0 m
Rack drive, heavy duty
4.0–9.0 m
Bi-folding
2–4
None
Articulated arm, fast cycle
Leaf Weight by Infill
Leaf mass drives hinge, post and operator selection. Values are for a 1.8 m high leaf, 6063-T5 frame at 2.5 mm wall, powder coated:
Infill type
Open area
Leaf mass (4.2 m span, 2 leaves)
Wind pressure rating
Vertical tube 25 × 25 mm
65%
46 kg / leaf
0.6 kPa
Horizontal slat 100 × 25 mm
40%
58 kg / leaf
0.9 kPa
Adjustable louvre
30–50%
64 kg / leaf
0.9 kPa
Perforated sheet 2.0 mm
35%
72 kg / leaf
1.1 kPa
Solid panel (composite)
0%
96 kg / leaf
1.5 kPa
Grade and Drainage Limits
A swing gate needs the leaf to clear the ground through the full arc: keep driveway cross-fall below 2% and longitudinal fall below 6% across the swing zone, or specify a rising hinge. Sliding and cantilever types need a level track line within ±3 mm over the full run — a ground beam is cast for tracked units, while cantilever units sit entirely on the post carriages and tolerate a crowned or gravel driveway.
Driveway Gates Automatic — Operator Sizing, UL 325 and Entrapment Protection
An automatic driveway gate converts the leaf into a machine. The operator, the safety devices and the gate structure are regulated together: in North America the gate must be built to ASTM F2200 and the operator listed to UL 325.
Operator Class and Duty Cycle
UL 325 assigns four use classes. Size the operator for the class, then apply a 1.5× margin on the calculated leaf load:
UL 325 class
Application
Cycles / day
Typical rated life
Operator type
Class I
Single-family residential
10–30
50,000 cycles
Articulated arm, ram
Class II
Multi-family / small commercial
30–80
100,000 cycles
Ram, underground
Class III
Industrial / limited access
80–300
300,000 cycles
Hydraulic, heavy rack
Class IV
Guarded industrial
300–1000
500,000 cycles
Hydraulic, continuous duty
Sizing Calculation
Take a 4.2 m double swing gate, 58 kg per leaf, 1.8 m high, solidity 60%. Wind pressure 0.9 kPa gives a wind force of 0.9 × 3.78 m² × 0.6 = 2.0 kN per leaf. Hinge friction adds roughly 8% of leaf weight. Required thrust per leaf lands near 2.6 kN; with the 1.5× margin the operator is specified at 4.0 kN minimum. A sliding unit is sized on mass instead: rolling resistance 0.06 × total gate mass, so a 240 kg sliding leaf needs 15 N plus acceleration allowance — specify 400 N pull force.
Entrapment Protection
Two independent protection devices are required on every automated vehicular gate: one non-contact (photo-electric beam) and one contact (sensing edge) or an inherent reversing system.
Photo eyes are mounted at 400–700 mm and 900–1100 mm above grade; the upper beam guards the vehicle body, the lower one guards children and pets.
Maximum reversal force measured at the leaf edge is 178 N (40 lbf); the operator must reverse within 2 seconds of contact.
Loops, RFID readers, GSM intercom and keypads are access control, not safety devices — they do not satisfy the entrapment requirement.
Access Control and Power
Control voltage 24 V DC for the safety circuit; mains feed 110–120 V / 220–240 V to the control board with a dedicated 15 A breaker and an earth rod at the post.
Battery backup 7 Ah keeps 120–200 cycles after mains loss; solar kit (80–120 W panel, 2 × 55 Ah) covers remote sites.
GSM intercom $120–260 per unit, keypad $45–90, RFID reader $60–140, inductive loop detector $55–110.
Cycle time: swing 12–18 s to 90°, sliding 8–14 s for a 5 m run, bi-folding 6–9 s.
Aluminum Gates Driveway — Alloy, Extrusion and Corrosion Data
Aluminum gates for driveway use are welded or mechanically assembled from extruded profiles. Gate frames carry higher mechanical load than window frames, so wall thickness and temper are specified one class above the window range.
Alloy and Temper Mechanical Properties
Alloy / temper
Tensile strength
Yield strength
Elongation
Where used
6063-T5
≥ 160 MPa
≥ 110 MPa
≥ 8%
Frame, slats, posts (standard)
6060-T66
≥ 215 MPa
≥ 160 MPa
≥ 8%
Cantilever bottom beam
6061-T6
≥ 260 MPa
≥ 240 MPa
≥ 8%
Carriage, hinge plates, brackets
6082-T6
≥ 310 MPa
≥ 260 MPa
≥ 8%
Long-span cantilever main beam
Elastic modulus is 69 GPa and density 2700 kg/m³ for all tempers above. Billet is 99.7% primary aluminium with a mill certificate traceable to the heat number.
Wall Thickness and Section
Gate frame outer profile: 100 × 50 × 2.5 mm for spans to 4.5 m; 120 × 60 × 3.0 mm from 4.5 m to 7.0 m.
Post: 100 × 100 × 3.0 mm swing; 150 × 150 × 4.0 mm sliding; 200 × 200 × 5.0 mm cantilever above 8 m.
Slat infill: 100 × 25 × 1.5 mm or 120 × 30 × 2.0 mm, spaced at 15–20 mm gap for 40% open area.
Cantilever bottom beam: 165 × 110 × 4.5 mm in 6060-T66 or 6082-T6, with an internal steel insert for spans above 9 m.
Surface Treatment Parameters
Finish
Film thickness
Cure / process
Salt spray (ASTM B117)
Typical warranty
Polyester powder (Interpon class 1)
60–80 μm
180–200 °C, 10–15 min
1000 h pass
10 years
PVDF fluorocarbon (70%)
25–35 μm
230 °C, 8–10 min
3000 h pass
20 years
Anodizing AA20
20 μm
Sulphuric, 18–22 °C
2000 h pass
15 years
Wood-grain sublimation
Powder base + 30–40 μm grain
200 °C, 8 min transfer
1000 h pass
10 years
Marine-grade duplex (anodize + powder)
20 μm + 70 μm
Two-stage line
4000 h pass
25 years
Coastal specification: within 800 m of salt water, use the marine-grade duplex or AA20 anodizing. Standard single-layer powder on a coastal site typically shows edge creep at cut ends after 3–5 years. On the same site a duplex finish adds $18–25/m² but removes the repainting cycle.
Entry Gates for Driveway — Setback, Clearance and Access Layout
An entry gate sits at the property boundary and interacts with the street. Beyond the gate itself, the layout determines whether vehicles can queue off the road and whether delivery and emergency access work.
Setback and Apron Dimensions
Element
Residential single dwelling
Multi-unit / commercial
Note
Gate setback from property line
0–1.5 m
3.0–6.0 m
Lets one car queue off the roadway
Apron depth inside gate
≥ 5.0 m
≥ 9.0 m
Vehicle length clear of the swing arc
Driveway width at gate
3.0–4.5 m
4.5–7.0 m
Two-way needs 6.0 m minimum
Turning radius inside gate
6.0 m
9.0–12.0 m
Measured to the front bumper path
Pedestrian leaf width
0.9–1.2 m
1.2 m
Separate leaf avoids opening the vehicle gate
Swing Arc and Obstruction Check
A 2.1 m swing leaf sweeps a quarter circle of 13.9 m². Before ordering, mark the arc on site and check for: parked-car positions, metre boxes, retaining walls, street trees and the fall of the ground. Where the arc is obstructed, switch to bi-folding (arc reduced to 40%) or to a sliding unit. Where the driveway slopes up from the street, swing leaves must open inward or a rising hinge is fitted to gain 50–80 mm of ground clearance at the arc.
Access Control Placement
Keypad or reader mounted 1.1 m above grade, 300–600 mm outside the gate on the approach side, reached without leaving the driver’s window.
Intercom camera at 1.5–1.7 m, angled 15° down, with an IR ring for night plates.
Photo eyes inside the gate line, never in the roadway: a beam broken by passing traffic holds the leaf open.
Where sight distance from the street is under 30 m, add a warning light on the post wired to the operator open/close cycle.
Commercial swing gate orders run on different terms from single residential units. Standard MOQ starts at 3 sets for catalogue sizes; custom extrusions carry a die charge and a longer first-article lead time.
MOQ and Volume Price Breaks
Order quantity
Discount off list
Tooling
Lead time
Notes
1–2 sets (sample)
List + 15%
None
20–25 days
Sample and fit-check order
3–9 sets
List
None
25–32 days
Standard MOQ for catalogue sizes
10–29 sets
− 6%
None
30–38 days
One powder colour per run
30–99 sets
− 12%
None
35–45 days
Mixed sizes permitted
100+ sets
− 18%
Die amortised
45–60 days
Dedicated production slot
Custom Extrusion and Tooling
New die for a bespoke slat or frame profile: $800–1,500, delivered in 12–15 days.
Die is amortised back into the unit price once the order passes 300 m² of that profile; most buyers reach the threshold at 30–40 sets.
First-article sample ships for approval before the production run; budget 8–10 extra days.
Freeze the shop drawing before the deposit — changes after extrusion starts are charged at the full profile cost.
Container Loading Math
A 40HQ gives 68 m³ usable volume and about 26 t payload. Aluminum gates are volume-limited, not weight-limited:
Gate set
Packed volume / set
Packed mass / set
Sets per 40HQ
Limiting factor
Double swing 4.2 × 1.8 m
1.55 m³
168 kg
36–40 sets
Volume
Single swing 3.0 × 1.8 m
1.05 m³
102 kg
54–60 sets
Volume
Sliding on track 5.0 m
1.95 m³
212 kg
30–32 sets
Volume
Cantilever 8.0 m
2.85 m³
386 kg
21–23 sets
Volume
Bi-folding 5.0 m
2.10 m³
245 kg
28–30 sets
Volume
Operators, keypads and control boards ship in the same crate as the leaf where possible; separate them only for customs classification if the destination applies a different duty rate to operators. See the packing and crating method in our door and window accessories procurement page.
Driveway Gate Price Table — FOB China Quotations in USD
Prices are FOB China per square metre of gate area (span × height), excluding automation, shipping and customs. They reflect export quotations from Foshan and Guangdong fabricators.
FOB Price by Gate Type and Infill
Gate type
Infill
Frame wall
Finish
FOB price (USD/m²)
Single swing
Vertical tube 25 × 25
2.0 mm
Powder 60 μm
$85–130
Double swing
Horizontal slat 40% open
2.5 mm
Powder 70 μm
$130–190
Double swing
Adjustable louvre
2.5 mm
Powder 70 μm
$175–260
Double swing
Solid composite panel
3.0 mm
Powder / PVDF
$190–280
Sliding on track
Horizontal slat
2.5 mm
Powder 70 μm
$145–215
Cantilever sliding
Slat / louvre
3.0 mm + 6082 beam
Powder 80 μm
$210–330
Bi-folding
Horizontal slat
3.0 mm
Powder 80 μm
$260–420
Automation and Access Add-Ons
Item
Specification
Unit price (USD)
Note
Articulated swing arm
24 V DC, 3.5 kN, Class I–II
$180–320
Per leaf
Underground ram
IP67, 4.0 kN, Class II
$420–680
Hidden, needs drainage sump
Sliding rack drive
400–800 N, 230 V / 24 V
$260–520
Includes 4 m rack
Cantilever drive
800–1600 N, Class III
$420–760
Heavy duty gearbox
Photo eye pair
IP54, 12–24 V, 15 m range
$35–70
Two pairs typical
Sensing edge
Rubber profile, 8.2 kΩ
$18–40 / m
Full leading-edge length
GSM intercom
4G, 2-relay, app control
$120–260
Plus SIM data plan
Battery backup + solar
7 Ah + 100 W panel
$150–290
Remote sites
Budgeting note: a 4.2 × 1.8 m double swing gate with slat infill at $165/m² costs $1,247 FOB for the gate; adding two swing arms ($260 each), two photo-eye pairs ($55 each), sensing edge ($110) and a keypad ($70) brings the automated package to about $2,060 FOB. A comparable local supply-and-install quote in the US or Australia runs $4,600–5,800 for the same configuration.
Production Process — Extrusion, Welding, Coating
The build sequence is: billet → extrusion → aging → cutting → welding → grinding → pre-treatment → coating → assembly → test. Each step carries a recorded parameter.
Extrusion, Aging and Cutting
Billet heated to 480–520 °C and pushed through the die at 8–25 m/min depending on section complexity.
Artificial aging at 180 °C for 6–8 h reaches the T5/T6 temper; hardness is checked on a Webster gauge (8–12 HW for 6063-T5).
Cutting on a double-head saw at ±0.2 mm with a 45° or 90° mitre; notching on a 4-axis CNC for slat slots at ±0.1 mm.
Every batch is checked for wall thickness at four points with an ultrasonic gauge; profiles outside ±0.1 mm are scrapped.
Welding and Mechanical Assembly
Frame corners are TIG welded (ER4043 filler, 1.6–2.4 mm) then ground flush to a 240-grit finish before coating — weld penetration is checked on one coupon per 100 frames.
Alternative mechanical build uses 6061-T6 corner gussets with M8 stainless bolts and two-component epoxy; shear capacity 3.2 kN per corner versus 2.6 kN for a standard weld.
Cantilever bottom beams are welded on a jig with a 3 mm pre-camber to offset dead-load deflection; the camber is verified against a straightedge before coating.
Slats are fixed with stainless rivets at 300 mm centres or clipped into a retained channel; rivet pull-out is tested at 1.8 kN.
Pre-treatment and Coating Line
Chromium-free pre-treatment: degrease → rinse → zirconium conversion → DI rinse → dry-off at 110 °C.
Powder applied electrostatically at 60–80 kV in a controlled booth (20–25 °C, humidity under 65%); overspray is recovered and sieved.
Cure 180–200 °C for 10–15 min measured on the metal, not the air — a data logger rides the line on every batch.
Dry-film thickness checked at six points per gate (target 60–80 μm); cross-hatch adhesion tested to ISO 2409 class 0.
Technical Indicators — Wind Load, Deflection, Post and Foundation
Gates are classified as external structures, not as building envelopes, so wind load is the governing check rather than thermal performance.
Wind Pressure and Infill Rating
Infill
Solidity
Design wind pressure
Leaf deflection at design load
Limit
Vertical tube
35%
0.6 kPa
L/180
L/120
Horizontal slat
60%
0.9 kPa
L/150
L/120
Adjustable louvre (closed)
70%
1.1 kPa
L/140
L/120
Perforated sheet
65%
1.1 kPa
L/145
L/120
Solid panel
100%
1.5 kPa
L/125
L/120
For a 2.1 m leaf, L/120 allows 17.5 mm of tip deflection. In wind-borne debris regions the assembly is designed to the local design pressure: ±2.4 kPa for ASCE 7 Risk Category II at 50 m/s in coastal Florida, ±1.5 kPa for AS/NZS 1170.2 Region B terrain category 3.
Post, Hinge and Foundation Sizing
Span
Post section
Hinges per leaf
Foundation (L × W × D)
Concrete
Up to 3.0 m
100 × 100 × 3.0 mm
2
400 × 400 × 600 mm
C25/30
3.0–4.5 m
100 × 100 × 4.0 mm
3
450 × 450 × 700 mm
C25/30
4.5–7.0 m
150 × 150 × 4.0 mm
3
500 × 500 × 800 mm
C30/37
Sliding to 8.0 m
150 × 150 × 5.0 mm
—
600 × 600 × 800 mm
C30/37
Cantilever to 12.0 m
200 × 200 × 5.0 mm
—
800 × 800 × 1000 mm
C30/37
Mechanical and Cycle Data
Hinge: cast aluminium or 304 stainless, adjustable on three axes, rated 250 kg per pair; grease nipple service every 12 months.
Roller carriage: sealed bearing 6204-2RS, dynamic load 12.8 kN, tested to 100,000 cycles at rated gate mass.
Track: 65 × 55 mm galvanised or 6061-T6 rail, 4 mm wall, fixed at 500 mm centres.
Locking: electric lock 12/24 V with a manual release key; mechanical drop bolt on the passive leaf.
Operating temperature range −20 °C to +55 °C; operator IP rating IP44 minimum, IP67 for underground units.
Certifications — CE, UL 325, ASTM F2200, AS/NZS and NOA
Export gates carry a market-specific mark. Confirm which set applies before production, because structural changes after certification void the listing.
Certification Map by Market
Market
Standard
Scope
Typical documentation lead
European Union
CE — EN 13241
Gates, doors, barriers for industrial/commercial/residential use
4–6 weeks
European Union
EN 12453
Safety in use of power operated gates
Included with EN 13241
European Union
EN 12604 / EN 12605
Mechanical aspects, test methods
Included
United States
UL 325
Gate operators and systems, 4 use classes
6–10 weeks
United States
ASTM F2200
Automated vehicular gate construction
With UL 325 file
Australia / NZ
AS/NZS 4505:2012
Garage doors and large access doors
3–5 weeks
Florida HVHZ
Miami-Dade NOA
TAS 201/202/203 impact and cyclic pressure
10–14 weeks
Factory
ISO 9001
Quality management system
Current certificate
What ASTM F2200 Checks on the Gate Itself
No opening in the gate or between gate and adjacent structure that will pass a 57 mm (2¼ in) sphere within 1.8 m of grade.
No protrusions or edges that can catch clothing in the travel path.
Exposed horizontal members spaced so the gate cannot be climbed where it guards a pool or a restricted area.
The gate must carry a permanent warning sign and the installer must fit the entrapment devices listed in the operator manual.
For projects in high-velocity hurricane zones the assembly is tested to TAS 201 (large-missile impact), TAS 202 (uniform static air pressure) and TAS 203 (cyclic wind pressure, 9,000 cycles at design pressure). The same structural approach is used for our house window systems rated for design wind pressure.
Procurement Data — MOQ, Lead Time, Payment, Packaging
Standard terms for a China export order of aluminum driveway gates.
Commercial Terms
MOQ: 3 sets for catalogue sizes; 1–2 sets accepted as a sample order at list + 15%.
Lead time: 25–32 days standard; 35–45 days with automation; add 12–15 days for a new extrusion die.
Payment: T/T 30% deposit, 70% against bill of lading copy; L/C at sight for orders above USD 50,000.
Incoterms: FOB Shenzhen / Guangzhou standard; CIF and DAP available on request.
Sample: a half-leaf section or a full sample gate within 15 days at cost, refunded against the first production order.
Warranty: 10 years on the frame and coating, 2 years on the operator and control board.
Packaging Specification
Each leaf wrapped in 8–10 mm PE foam, corner protected with 3 mm cardboard, then bubble wrapped.
Gates crated in ISPM-15 stamped plywood cases with a steel strap; the crate is rated for 800 kg and stackable two high.
Posts and tracks bundled separately in foam sleeving; operators boxed with foam inserts and shipped in the same container.
LCL shipments are palletised with edge protectors and stretch film; FCL ships loose-crated to maximise container use.
Each crate carries the shop drawing number, the RAL code and the destination marked on two faces.
Quality Control Before Shipment
100% inspection (not sampling) on: weld appearance, coating thickness at six points, leaf squareness within ±2 mm over 2 m, hinge alignment and lock engagement.
Cycle test on one gate per batch: 200 open/close cycles on the fitted operator, reversal force measured at the leading edge.
Digital photo set of every crate sent before the balance payment is due.
Mill certificates for the extrusion batch and coating batch are included in the shipping document pack.
Installation Method — Site Survey, Foundation, Commissioning
Most gate failures trace back to the foundation or to an undersized operator, not to the leaf. The sequence below is the factory-recommended method.
Site Survey and Setting Out
Measure the clear opening at three heights; use the smallest reading as the manufacturing width and deduct 10 mm total for hinge and latch clearance.
Check the gradient: cross-fall under 2% and longitudinal fall under 6% for swing; level within ±3 mm over the full run for sliding.
Locate the power run and conduit before concrete; a 32 mm conduit to the hinge post covers the operator cable and the safety-device loop.
Mark the swing arc or the slide run on the ground and confirm no obstruction, then set the post centres.
Foundation and Post Installation
Excavate to the foundation size from the table in section 8; add 100 mm of compacted hardcore below the pour.
Set the M16 anchor bolts on a plywood template, bolt centres checked to ±1 mm.
Pour C25/30 or C30/37 concrete with 40 mm cover to the bolt shank; vibrate to remove voids.
Cure 7 days minimum before hanging the leaf — hanging early is the single most common cause of a leaning post.
Check post plumb to ±2 mm over 2 m and the centre distance against the shop drawing.
Hanging, Automation and Commissioning
Hang the leaves on adjustable hinges; set a 10–15 mm gap between meeting leaves and 40–50 mm ground clearance.
Fit the stops, the drop bolt on the passive leaf and the electric lock on the active leaf.
Mount the operator per the UL 325 file: the operator and gate combination must match the listed construction.
Install the photo eyes and the sensing edge; wire the safety circuit on the 24 V monitored input, never in parallel with the accessory feed.
Commission: measure the reversal force at the leading edge (must be under 178 N), confirm reverse within 2 s, run 20 full cycles and record the results.
Hand over with the operator manual, the warning signs fitted to both faces and the maintenance schedule (hinge grease and bolt torque at 6 months, then annually).
Three failure points to check: (1) foundation smaller than the table in section 8 — the post leans and the leaf drags within 12 months; (2) operator sized on leaf weight alone with no wind allowance — the motor overheats in the first storm season; (3) safety devices wired to the accessory input instead of the monitored safety input — the gate fails the entrapment test at inspection.
Customer Case — 46-Unit Townhouse Development
A 46-unit townhouse development in Texas specified one double swing driveway gate per unit plus two commercial sliding gates at the main entrance. Gate configuration: 4.2 m clear opening, 1.8 m high, horizontal slat infill at 40% open area, 6063-T5 frame at 2.5 mm, 150 × 150 × 4.0 mm posts, polyester powder at 70 μm in RAL 7016, driven by two 24 V articulated arms rated Class II.
Delivered Cost Comparison (per unit gate, USD)
Cost element
Local supply and install
China FOB + landed
Delta
Gate leaf and frame
$2,650
$1,247 FOB
–
Automation package
$1,180
$530
–
Freight, duty, customs
—
$505
–
Local install, concrete, electrical
$1,350
$720
–
Total installed per gate
$5,180
$3,002
− 42.0%
Project total (48 gates)
$248,640
$144,096
− $104,544
Project Data
Order size: 46 residential double swing gates + 2 × 8.0 m cantilever sliding gates, MOQ 3 met at the sample stage and the volume break applied at the 30-set tier (−12%).
Lead time: 38 days production for the swing gates, 45 days for the cantilever units; container transit 26 days to Houston, 4 days clearance.
Container use: two 40HQ containers, 24 swing gate sets each (volume-limited at 1.55 m³/set), cantilever sets shipped on the second container as break-bulk.
Installed performance: measured reversal force 142 N at the leading edge, cycle time 14 s to 90°, no call-backs in the first 14 months.
Certification: operators listed to UL 325 Class II, gates built to ASTM F2200; the cantilever units were designed to 1.5 kPa for the local wind map.
Configuration Comparison — Aluminum, Steel and Wrought Iron
Material choice sets the operator class, the foundation size and the maintenance budget.
Material Comparison
Parameter
Aluminum 6063-T5
Galvanised steel
Wrought iron / cast
Density
2700 kg/m³
7850 kg/m³
7200 kg/m³
Leaf mass (4.2 × 1.8 m, slat)
58 kg
146 kg
132 kg
Operator class required
Class I–II
Class III
Class III
Foundation (double swing)
450 × 450 × 700
600 × 600 × 900
600 × 600 × 900
Salt spray 1000 h (ASTM B117)
Pass, no base metal attack
White rust at cut edges
Red rust, coating failure
Coastal maintenance cycle
Wash, no repaint
Touch-up every 2–3 yr
Repaint every 1–2 yr
FOB price (USD/m²)
$130–280
$95–180
$210–420
Sets per 40HQ
36–40
22–26
20–24
Gate Type Comparison
Criterion
Double swing
Sliding on track
Cantilever
Bi-folding
Max span
7.0 m
8.0 m
12.0 m
9.0 m
Side room needed
None
Opening + 5%
Opening × 0.55
None
Ground track
No
Yes
No
No
Handles sloping drive
With rising hinge
No
Yes
Yes
Cycle time (5 m)
14 s
11 s
12 s
7 s
Foundation cost
Medium
Low
High
Medium
FOB (USD/m²)
$130–280
$145–215
$210–330
$260–420
Choose double swing where side room is tight and the drive is near level. Choose an on-track slider on a level site with clear run. Choose cantilever where the drive is gravel, crowned, steep or snow-affected — no ground track to clear. Choose bi-folding where opening speed matters, such as a shared commercial entrance.