A driveway gate is a vehicular access barrier spanning a private or commercial entrance, hung on posts or running on a track. In China the export build is a 6063-T5 aluminum extrusion frame with slat, louvre, tube or solid infill, finished by powder coat or anodizing and optionally driven by an automatic operator. This article documents the geometry selection, operator sizing, alloy and coating parameters, wind and deflection data, certification set, FOB price tables, procurement terms, installation sequence and delivered project cost for aluminum driveway gates produced in China, with USD figures and side-by-side configuration comparisons.
FOB price
$85–420/m²
Frame wall
2.0 / 2.5 / 3.0 mm
Span range
2.5–12.0 m
MOQ
3 sets standard
Lead time
25–45 days
Contents
1. Driveway Gate Types by Span
2. Driveway Gates Automatic
3. Aluminum Gates Driveway
4. Entry Gates for Driveway
5. Commercial Swing Gate Orders
6. FOB Price Table (USD)
7. Production Process
8. Technical Indicators
9. Certifications
10. Procurement Data
11. Installation Method
12. Customer Case
13. Configuration Comparison
14. Related Products

Driveway Gate Types — Span, Leaf Count and Running Clearance

Gate type follows the clear opening, the side room available and the driveway gradient. Pick the type from the span first, then check that the site can physically accommodate the run or swing arc.

Span-to-Type Selection Table

Clear opening Gate type Leaves Side run required Drive unit
2.5–4.0 m Single swing 1 None (swing arc) Articulated arm / hydraulic ram
4.0–7.0 m Double swing 2 None (swing arc) 2 × ram or underground
4.0–8.0 m Sliding on track 1 Opening × 1.05 + 0.3 m Rack-and-pinion drive
5.0–12.0 m Cantilever sliding 1 Opening × 0.55 tail + 1.0 m Rack drive, heavy duty
4.0–9.0 m Bi-folding 2–4 None Articulated arm, fast cycle

Leaf Weight by Infill

Leaf mass drives hinge, post and operator selection. Values are for a 1.8 m high leaf, 6063-T5 frame at 2.5 mm wall, powder coated:

Infill type Open area Leaf mass (4.2 m span, 2 leaves) Wind pressure rating
Vertical tube 25 × 25 mm 65% 46 kg / leaf 0.6 kPa
Horizontal slat 100 × 25 mm 40% 58 kg / leaf 0.9 kPa
Adjustable louvre 30–50% 64 kg / leaf 0.9 kPa
Perforated sheet 2.0 mm 35% 72 kg / leaf 1.1 kPa
Solid panel (composite) 0% 96 kg / leaf 1.5 kPa

Grade and Drainage Limits

A swing gate needs the leaf to clear the ground through the full arc: keep driveway cross-fall below 2% and longitudinal fall below 6% across the swing zone, or specify a rising hinge. Sliding and cantilever types need a level track line within ±3 mm over the full run — a ground beam is cast for tracked units, while cantilever units sit entirely on the post carriages and tolerate a crowned or gravel driveway.

Driveway Gates Automatic — Operator Sizing, UL 325 and Entrapment Protection

An automatic driveway gate converts the leaf into a machine. The operator, the safety devices and the gate structure are regulated together: in North America the gate must be built to ASTM F2200 and the operator listed to UL 325.

Operator Class and Duty Cycle

UL 325 assigns four use classes. Size the operator for the class, then apply a 1.5× margin on the calculated leaf load:

UL 325 class Application Cycles / day Typical rated life Operator type
Class I Single-family residential 10–30 50,000 cycles Articulated arm, ram
Class II Multi-family / small commercial 30–80 100,000 cycles Ram, underground
Class III Industrial / limited access 80–300 300,000 cycles Hydraulic, heavy rack
Class IV Guarded industrial 300–1000 500,000 cycles Hydraulic, continuous duty

Sizing Calculation

Take a 4.2 m double swing gate, 58 kg per leaf, 1.8 m high, solidity 60%. Wind pressure 0.9 kPa gives a wind force of 0.9 × 3.78 m² × 0.6 = 2.0 kN per leaf. Hinge friction adds roughly 8% of leaf weight. Required thrust per leaf lands near 2.6 kN; with the 1.5× margin the operator is specified at 4.0 kN minimum. A sliding unit is sized on mass instead: rolling resistance 0.06 × total gate mass, so a 240 kg sliding leaf needs 15 N plus acceleration allowance — specify 400 N pull force.

Entrapment Protection

Access Control and Power

Aluminum Gates Driveway — Alloy, Extrusion and Corrosion Data

Aluminum gates for driveway use are welded or mechanically assembled from extruded profiles. Gate frames carry higher mechanical load than window frames, so wall thickness and temper are specified one class above the window range.

Alloy and Temper Mechanical Properties

Alloy / temper Tensile strength Yield strength Elongation Where used
6063-T5 ≥ 160 MPa ≥ 110 MPa ≥ 8% Frame, slats, posts (standard)
6060-T66 ≥ 215 MPa ≥ 160 MPa ≥ 8% Cantilever bottom beam
6061-T6 ≥ 260 MPa ≥ 240 MPa ≥ 8% Carriage, hinge plates, brackets
6082-T6 ≥ 310 MPa ≥ 260 MPa ≥ 8% Long-span cantilever main beam

Elastic modulus is 69 GPa and density 2700 kg/m³ for all tempers above. Billet is 99.7% primary aluminium with a mill certificate traceable to the heat number.

Wall Thickness and Section

Surface Treatment Parameters

Finish Film thickness Cure / process Salt spray (ASTM B117) Typical warranty
Polyester powder (Interpon class 1) 60–80 μm 180–200 °C, 10–15 min 1000 h pass 10 years
PVDF fluorocarbon (70%) 25–35 μm 230 °C, 8–10 min 3000 h pass 20 years
Anodizing AA20 20 μm Sulphuric, 18–22 °C 2000 h pass 15 years
Wood-grain sublimation Powder base + 30–40 μm grain 200 °C, 8 min transfer 1000 h pass 10 years
Marine-grade duplex (anodize + powder) 20 μm + 70 μm Two-stage line 4000 h pass 25 years
Coastal specification: within 800 m of salt water, use the marine-grade duplex or AA20 anodizing. Standard single-layer powder on a coastal site typically shows edge creep at cut ends after 3–5 years. On the same site a duplex finish adds $18–25/m² but removes the repainting cycle.

Entry Gates for Driveway — Setback, Clearance and Access Layout

An entry gate sits at the property boundary and interacts with the street. Beyond the gate itself, the layout determines whether vehicles can queue off the road and whether delivery and emergency access work.

Setback and Apron Dimensions

Element Residential single dwelling Multi-unit / commercial Note
Gate setback from property line 0–1.5 m 3.0–6.0 m Lets one car queue off the roadway
Apron depth inside gate ≥ 5.0 m ≥ 9.0 m Vehicle length clear of the swing arc
Driveway width at gate 3.0–4.5 m 4.5–7.0 m Two-way needs 6.0 m minimum
Turning radius inside gate 6.0 m 9.0–12.0 m Measured to the front bumper path
Pedestrian leaf width 0.9–1.2 m 1.2 m Separate leaf avoids opening the vehicle gate

Swing Arc and Obstruction Check

A 2.1 m swing leaf sweeps a quarter circle of 13.9 m². Before ordering, mark the arc on site and check for: parked-car positions, metre boxes, retaining walls, street trees and the fall of the ground. Where the arc is obstructed, switch to bi-folding (arc reduced to 40%) or to a sliding unit. Where the driveway slopes up from the street, swing leaves must open inward or a rising hinge is fitted to gain 50–80 mm of ground clearance at the arc.

Access Control Placement

Driveway Swing Gates Commercial — MOQ, Volume Breaks and Container Loading

Commercial swing gate orders run on different terms from single residential units. Standard MOQ starts at 3 sets for catalogue sizes; custom extrusions carry a die charge and a longer first-article lead time.

MOQ and Volume Price Breaks

Order quantity Discount off list Tooling Lead time Notes
1–2 sets (sample) List + 15% None 20–25 days Sample and fit-check order
3–9 sets List None 25–32 days Standard MOQ for catalogue sizes
10–29 sets − 6% None 30–38 days One powder colour per run
30–99 sets − 12% None 35–45 days Mixed sizes permitted
100+ sets − 18% Die amortised 45–60 days Dedicated production slot

Custom Extrusion and Tooling

Container Loading Math

A 40HQ gives 68 m³ usable volume and about 26 t payload. Aluminum gates are volume-limited, not weight-limited:

Gate set Packed volume / set Packed mass / set Sets per 40HQ Limiting factor
Double swing 4.2 × 1.8 m 1.55 m³ 168 kg 36–40 sets Volume
Single swing 3.0 × 1.8 m 1.05 m³ 102 kg 54–60 sets Volume
Sliding on track 5.0 m 1.95 m³ 212 kg 30–32 sets Volume
Cantilever 8.0 m 2.85 m³ 386 kg 21–23 sets Volume
Bi-folding 5.0 m 2.10 m³ 245 kg 28–30 sets Volume

Operators, keypads and control boards ship in the same crate as the leaf where possible; separate them only for customs classification if the destination applies a different duty rate to operators. See the packing and crating method in our door and window accessories procurement page.

Driveway Gate Price Table — FOB China Quotations in USD

Prices are FOB China per square metre of gate area (span × height), excluding automation, shipping and customs. They reflect export quotations from Foshan and Guangdong fabricators.

FOB Price by Gate Type and Infill

Gate type Infill Frame wall Finish FOB price (USD/m²)
Single swing Vertical tube 25 × 25 2.0 mm Powder 60 μm $85–130
Double swing Horizontal slat 40% open 2.5 mm Powder 70 μm $130–190
Double swing Adjustable louvre 2.5 mm Powder 70 μm $175–260
Double swing Solid composite panel 3.0 mm Powder / PVDF $190–280
Sliding on track Horizontal slat 2.5 mm Powder 70 μm $145–215
Cantilever sliding Slat / louvre 3.0 mm + 6082 beam Powder 80 μm $210–330
Bi-folding Horizontal slat 3.0 mm Powder 80 μm $260–420

Automation and Access Add-Ons

Item Specification Unit price (USD) Note
Articulated swing arm 24 V DC, 3.5 kN, Class I–II $180–320 Per leaf
Underground ram IP67, 4.0 kN, Class II $420–680 Hidden, needs drainage sump
Sliding rack drive 400–800 N, 230 V / 24 V $260–520 Includes 4 m rack
Cantilever drive 800–1600 N, Class III $420–760 Heavy duty gearbox
Photo eye pair IP54, 12–24 V, 15 m range $35–70 Two pairs typical
Sensing edge Rubber profile, 8.2 kΩ $18–40 / m Full leading-edge length
GSM intercom 4G, 2-relay, app control $120–260 Plus SIM data plan
Battery backup + solar 7 Ah + 100 W panel $150–290 Remote sites
Budgeting note: a 4.2 × 1.8 m double swing gate with slat infill at $165/m² costs $1,247 FOB for the gate; adding two swing arms ($260 each), two photo-eye pairs ($55 each), sensing edge ($110) and a keypad ($70) brings the automated package to about $2,060 FOB. A comparable local supply-and-install quote in the US or Australia runs $4,600–5,800 for the same configuration.

Production Process — Extrusion, Welding, Coating

The build sequence is: billet → extrusion → aging → cutting → welding → grinding → pre-treatment → coating → assembly → test. Each step carries a recorded parameter.

Extrusion, Aging and Cutting

Welding and Mechanical Assembly

Pre-treatment and Coating Line

Technical Indicators — Wind Load, Deflection, Post and Foundation

Gates are classified as external structures, not as building envelopes, so wind load is the governing check rather than thermal performance.

Wind Pressure and Infill Rating

Infill Solidity Design wind pressure Leaf deflection at design load Limit
Vertical tube 35% 0.6 kPa L/180 L/120
Horizontal slat 60% 0.9 kPa L/150 L/120
Adjustable louvre (closed) 70% 1.1 kPa L/140 L/120
Perforated sheet 65% 1.1 kPa L/145 L/120
Solid panel 100% 1.5 kPa L/125 L/120

For a 2.1 m leaf, L/120 allows 17.5 mm of tip deflection. In wind-borne debris regions the assembly is designed to the local design pressure: ±2.4 kPa for ASCE 7 Risk Category II at 50 m/s in coastal Florida, ±1.5 kPa for AS/NZS 1170.2 Region B terrain category 3.

Post, Hinge and Foundation Sizing

Span Post section Hinges per leaf Foundation (L × W × D) Concrete
Up to 3.0 m 100 × 100 × 3.0 mm 2 400 × 400 × 600 mm C25/30
3.0–4.5 m 100 × 100 × 4.0 mm 3 450 × 450 × 700 mm C25/30
4.5–7.0 m 150 × 150 × 4.0 mm 3 500 × 500 × 800 mm C30/37
Sliding to 8.0 m 150 × 150 × 5.0 mm — 600 × 600 × 800 mm C30/37
Cantilever to 12.0 m 200 × 200 × 5.0 mm — 800 × 800 × 1000 mm C30/37

Mechanical and Cycle Data

Certifications — CE, UL 325, ASTM F2200, AS/NZS and NOA

Export gates carry a market-specific mark. Confirm which set applies before production, because structural changes after certification void the listing.

Certification Map by Market

Market Standard Scope Typical documentation lead
European Union CE — EN 13241 Gates, doors, barriers for industrial/commercial/residential use 4–6 weeks
European Union EN 12453 Safety in use of power operated gates Included with EN 13241
European Union EN 12604 / EN 12605 Mechanical aspects, test methods Included
United States UL 325 Gate operators and systems, 4 use classes 6–10 weeks
United States ASTM F2200 Automated vehicular gate construction With UL 325 file
Australia / NZ AS/NZS 4505:2012 Garage doors and large access doors 3–5 weeks
Florida HVHZ Miami-Dade NOA TAS 201/202/203 impact and cyclic pressure 10–14 weeks
Factory ISO 9001 Quality management system Current certificate

What ASTM F2200 Checks on the Gate Itself

For projects in high-velocity hurricane zones the assembly is tested to TAS 201 (large-missile impact), TAS 202 (uniform static air pressure) and TAS 203 (cyclic wind pressure, 9,000 cycles at design pressure). The same structural approach is used for our house window systems rated for design wind pressure.

Procurement Data — MOQ, Lead Time, Payment, Packaging

Standard terms for a China export order of aluminum driveway gates.

Commercial Terms

Packaging Specification

Quality Control Before Shipment

Installation Method — Site Survey, Foundation, Commissioning

Most gate failures trace back to the foundation or to an undersized operator, not to the leaf. The sequence below is the factory-recommended method.

Site Survey and Setting Out

  1. Measure the clear opening at three heights; use the smallest reading as the manufacturing width and deduct 10 mm total for hinge and latch clearance.
  2. Check the gradient: cross-fall under 2% and longitudinal fall under 6% for swing; level within ±3 mm over the full run for sliding.
  3. Locate the power run and conduit before concrete; a 32 mm conduit to the hinge post covers the operator cable and the safety-device loop.
  4. Mark the swing arc or the slide run on the ground and confirm no obstruction, then set the post centres.

Foundation and Post Installation

  1. Excavate to the foundation size from the table in section 8; add 100 mm of compacted hardcore below the pour.
  2. Set the M16 anchor bolts on a plywood template, bolt centres checked to ±1 mm.
  3. Pour C25/30 or C30/37 concrete with 40 mm cover to the bolt shank; vibrate to remove voids.
  4. Cure 7 days minimum before hanging the leaf — hanging early is the single most common cause of a leaning post.
  5. Check post plumb to ±2 mm over 2 m and the centre distance against the shop drawing.

Hanging, Automation and Commissioning

  1. Hang the leaves on adjustable hinges; set a 10–15 mm gap between meeting leaves and 40–50 mm ground clearance.
  2. Fit the stops, the drop bolt on the passive leaf and the electric lock on the active leaf.
  3. Mount the operator per the UL 325 file: the operator and gate combination must match the listed construction.
  4. Install the photo eyes and the sensing edge; wire the safety circuit on the 24 V monitored input, never in parallel with the accessory feed.
  5. Commission: measure the reversal force at the leading edge (must be under 178 N), confirm reverse within 2 s, run 20 full cycles and record the results.
  6. Hand over with the operator manual, the warning signs fitted to both faces and the maintenance schedule (hinge grease and bolt torque at 6 months, then annually).
Three failure points to check: (1) foundation smaller than the table in section 8 — the post leans and the leaf drags within 12 months; (2) operator sized on leaf weight alone with no wind allowance — the motor overheats in the first storm season; (3) safety devices wired to the accessory input instead of the monitored safety input — the gate fails the entrapment test at inspection.

Customer Case — 46-Unit Townhouse Development

A 46-unit townhouse development in Texas specified one double swing driveway gate per unit plus two commercial sliding gates at the main entrance. Gate configuration: 4.2 m clear opening, 1.8 m high, horizontal slat infill at 40% open area, 6063-T5 frame at 2.5 mm, 150 × 150 × 4.0 mm posts, polyester powder at 70 μm in RAL 7016, driven by two 24 V articulated arms rated Class II.

Delivered Cost Comparison (per unit gate, USD)

Cost element Local supply and install China FOB + landed Delta
Gate leaf and frame $2,650 $1,247 FOB –
Automation package $1,180 $530 –
Freight, duty, customs — $505 –
Local install, concrete, electrical $1,350 $720 –
Total installed per gate $5,180 $3,002 − 42.0%
Project total (48 gates) $248,640 $144,096 − $104,544

Project Data

Configuration Comparison — Aluminum, Steel and Wrought Iron

Material choice sets the operator class, the foundation size and the maintenance budget.

Material Comparison

Parameter Aluminum 6063-T5 Galvanised steel Wrought iron / cast
Density 2700 kg/m³ 7850 kg/m³ 7200 kg/m³
Leaf mass (4.2 × 1.8 m, slat) 58 kg 146 kg 132 kg
Operator class required Class I–II Class III Class III
Foundation (double swing) 450 × 450 × 700 600 × 600 × 900 600 × 600 × 900
Salt spray 1000 h (ASTM B117) Pass, no base metal attack White rust at cut edges Red rust, coating failure
Coastal maintenance cycle Wash, no repaint Touch-up every 2–3 yr Repaint every 1–2 yr
FOB price (USD/m²) $130–280 $95–180 $210–420
Sets per 40HQ 36–40 22–26 20–24

Gate Type Comparison

Criterion Double swing Sliding on track Cantilever Bi-folding
Max span 7.0 m 8.0 m 12.0 m 9.0 m
Side room needed None Opening + 5% Opening × 0.55 None
Ground track No Yes No No
Handles sloping drive With rising hinge No Yes Yes
Cycle time (5 m) 14 s 11 s 12 s 7 s
Foundation cost Medium Low High Medium
FOB (USD/m²) $130–280 $145–215 $210–330 $260–420

Choose double swing where side room is tight and the drive is near level. Choose an on-track slider on a level site with clear run. Choose cantilever where the drive is gravel, crowned, steep or snow-affected — no ground track to clear. Choose bi-folding where opening speed matters, such as a shared commercial entrance.

For the wider exterior gate range and the mechanical comparison between sliding, swing and cantilever drives, see our aluminum gate supplier specifications. Spanish-market buyers can review the sliding and driveway gate designs in metal, and the steel versus aluminum door comparison covers the material question in more depth. For automated vehicular access on the garage side, the insulated garage door panels and roll-up specifications apply the same operator sizing logic. Related opening systems: aluminum bifold and accordion systems, sliding patio door specifications, aluminium windows and doors wholesale data and aluminum entrance door U-value tables; the supplier evaluation checklist documents how to verify a factory before placing a gate order.