A folding door is the only large-opening format where the structural load path, the thermal break and the weather seal are all resolved inside one moving panel edge. This page documents the numbers that decide whether a set survives five years of daily operation: panel width limits for each profile series, roller load ratings against real panel weights, Uw results by thermal break width, AAMA and EN classification data, FOB Foshan price bands, container loading and a 38-unit townhouse project cost breakdown from Seattle.
USD 108-420
FOB Foshan per m2 by series
Uw 1.6-5.8
W/m2K, double glazed low-E
1.8-2.4 mm
6063-T5 / T6 wall thickness
20 m2
Minimum order quantity
25-35 days
Production lead time
Contents
Panel Configuration and Width MathAluminum Folding Door Profiles and U-ValuesBifold Door Hardware: Load Ratings and TracksAccordion Doors Folding: Air, Water and Wind RatingsFolding Gate Systems for PerimetersGlazing Options and Weight LimitsFOB Price Bands and Landed CostCertification Map: NFRC, AAMA, CE, AS2047MOQ, Lead Time, Packing and Container LoadingInstallation: Eight Steps and Three Failure PointsFolding vs Sliding vs Lift-and-Slide vs FrenchProject Data: 38 Townhouses in Seattle

1. Folding Door Configurations and Panel Width Math

Configuration is written as panel count plus traffic door, e.g. 3+1. The number before the plus is the panels that stack; the number after is a swing leaf used for daily access without breaking the stack. The rule that drives every downstream decision is panel width: keep individual leaf width at 700-900 mm. Wider leaves increase roller moment load, increase glass weight per panel, and raise the risk of corner drop at the leading edge within 24 months.

Panel Count Versus Opening Width

Opening width (mm) Panels Config Leaf width (mm) Stacking width (mm) Recommended series
1,800 – 2,400 2 2+0 850 – 1,200 170 – 200 FD-70 / FD-80
2,400 – 3,600 3 3+0 or 2+1 800 – 1,200 260 – 300 FD-80
3,600 – 4,800 4 3+1 900 – 1,200 390 – 440 FD-80 / FD-90
4,800 – 6,000 5 4+1 or 5+0 960 – 1,200 520 – 580 FD-90
6,000 – 7,200 6 3+3 (centre open) 1,000 – 1,200 2 x 300 FD-90 / FD-110
7,200 – 8,400 7 3+3+1 1,030 – 1,200 2 x 300 + 200 FD-110

Table 1. Panel count is a function of opening width; leaf width above 1,200 mm requires a reinforced stile and a 160 kg roller set.

Traffic Door and Stacking Direction

A traffic door adds roughly USD 95-140 per set to hardware cost but removes 80% of full-stack cycles in a family dwelling. Stacking direction should be decided by the wall the panels land against: stacking on the side with no light switch, no radiator and at least 300 mm of clear wall. On corner sets, a 90-degree open corner removes the corner post entirely, but the two head tracks must be levelled to within 1 mm over the full span or the lead panel will bind.

Opening Direction: In-Swing or Out-Swing

Full configuration options, including corner and radius sets, are covered in the accordion door configurations page.

2. Aluminum Folding Door Profiles and Thermal Performance

The folding door frame is a moving structure, so the profile has to carry the panel load and still break the thermal bridge. All series below are extruded from 6063 primary aluminium billet, not secondary scrap alloy; recycled-content billet lowers tensile strength by roughly 8-12% and produces visible die lines after anodising.

6063-T5 Versus 6063-T6 Mechanical Data

Property 6063-T5 6063-T6 Test standard Where it is used
Tensile strength 160 MPa 205 MPa GB/T 228.1 / ASTM B221 T6 for panels above 2.7 m
Yield strength (0.2%) 110 MPa 170 MPa GB/T 228.1 T6 for coastal wind zones
Elongation 8% 8% GB/T 228.1 Both
Hardness (Webster) 8 HW 11.5 HW YS/T 420 T5 minimum for frames
Elastic modulus 68.9 GPa 68.9 GPa – Deflection calculation
Density 2.70 g/cm3 2.70 g/cm3 – Panel weight calculation

Table 2. 6063 mechanical properties. Wall thickness is verified at 1.8 mm for residential frames and 2.0-2.4 mm for commercial and HVHZ applications.

Thermal Break Width and Resulting Uw

The thermal break is a polyamide 66 strip reinforced with 25% glass fibre (PA66GF25), thermal conductivity 0.30 W/mK against 160 W/mK for aluminium. Every 5 mm of additional break width returns roughly 0.35-0.45 W/m2K on the frame value.

Series Frame depth (mm) Break width (mm) Uf (W/m2K) Uw with DG low-E argon (W/m2K) Max leaf height (mm)
FD-60 (non-break) 60 – 6.9 5.8 2,400
FD-70 70 14.8 3.9 3.2 2,600
FD-80 80 20.0 3.1 2.6 2,800
FD-90 90 24.0 2.6 2.1 3,000
FD-110 110 30.0 1.9 1.6 3,200

Table 3. Uw calculated to EN ISO 10077-2 on a 4,000 x 2,400 mm reference opening, 4-panel 3+1, double glazing 5+12Ar+5 low-E (Ug 1.1). Triple glazing lowers FD-90 to Uw 1.7 and FD-110 to Uw 1.3.

Surface Treatment Specification

The trade pricing structure for these series is documented on the aluminium folding door wholesale range page.

3. Bifold Door Hardware: Load Ratings and Track Systems

Hardware failure accounts for more than 70% of folding door service calls, and almost all of it traces back to one calculation error: specifying rollers against total opening weight rather than per-panel weight. Each leaf is carried by its own top roller and bottom pivot; the rating on the component is per panel, not per set.

Top-Hung Versus Bottom-Rolling

Criterion Top-hung Bottom-rolling Implication
Load carried at Head track Floor track Top-hung needs a structural header
Header deflection limit L/500 (typically 3-4 mm) Not critical Steel lintel or engineered beam required
Threshold Flush or 5 mm low profile 15-20 mm track Top-hung suits accessible thresholds
Max panel weight 120 kg 160 kg Very tall glass needs bottom-rolling
Track debris sensitivity Low High Bottom track needs drainage slots
Cost index 100 78 Bottom-rolling is cheaper to buy, costlier to maintain

Table 4. Top-hung is the default for residential sets under 3.0 m height; bottom-rolling is used for commercial spans and for leaves above 120 kg.

Roller and Hinge Load Calculation

Panel weight is leaf area multiplied by glazing weight plus frame weight. A 900 x 2,400 mm leaf with 6+12A+6 double glazing weighs about 78 kg. The engineering rule is a 60% safety margin on the roller rating, because dynamic load at the moment the panel leaves the track can exceed the static weight by 20-30%.

Leaf size (mm) Glazing build-up Panel weight (kg) Minimum roller rating (kg) Specified set
800 x 2,200 5+12A+5 58 93 100 kg
900 x 2,400 6+12A+6 78 125 130 kg
1,000 x 2,700 6+12Ar+6 low-E 96 154 160 kg
1,100 x 3,000 6+16Ar+6 laminated 132 211 Bottom-rolling 2 x 130 kg
1,200 x 3,200 8+16Ar+8 laminated 168 269 Bottom-rolling tandem

Table 5. Roller sizing with a 60% dynamic safety margin. Stainless 304 bearings are standard; 316 is specified within 5 km of a coastline.

Cycle Test Data and Replacement Interval

Roller and track selection interacts directly with the slide engineering described in the slide system hardware engineering reference.

4. Accordion Doors Folding: Air, Water and Wind Ratings

A folding door has more moving joints per linear metre than any other glazed format, so sealing design carries the whole performance envelope. An “accordion doors folding” set typically has 3 to 6 vertical meeting stiles, each of which is both a structural connection and an air seal line.

Classification Results by Series

Series Air permeability Watertightness Wind load resistance Acoustic Rw (dB) Standard
FD-70 Class 3 (600 Pa) 5A (200 Pa) C3 (1,200 Pa) 32 EN 14351-1
FD-80 Class 4 (600 Pa) 7A (300 Pa) C4 (1,600 Pa) 35 EN 14351-1
FD-90 Class 4 (600 Pa) 9A (600 Pa) C5 (2,000 Pa) 38 EN 14351-1
FD-110 HVHZ Class 4 (600 Pa) 9A (600 Pa) 2,400 Pa / +-65 psf 40 EN + TAS 201/202/203

Table 6. Accordion folding door classification. North American reporting converts to AAMA/WDMA/CSA 101/I.S.2/A440: Class 4 air maps to 0.3 cfm/ft2 at 1.57 psf, 7A water to DP50 water at 7.5 psf.

Sill Options: Flush, Weathered and Rebated

Gasket and Brush Seal Specification

Where a folding set is being matched to other glazed formats in the same elevation, the sliding patio door systems page gives the equivalent sliding-door classification figures.

5. Folding Gate Systems for Perimeters and Commercial Fronts

The same folding kinematics scale to perimeter security. A folding gate is the correct answer where the driveway has less than 1.2 m of side room for a sliding gate to retract into, or where the opening exceeds 5 m and a swing pair would need leaves too heavy for a standard operator.

Folding Gate Configurations and Span

Opening width (m) Leaves Leaf weight (kg) Operator thrust (N) Cycle time (s) Track
3.0 – 4.0 2 42 – 58 1,200 12 – 14 Top-hung
4.0 – 5.5 3 38 – 52 1,600 14 – 17 Top-hung
5.5 – 7.0 4 36 – 48 2,000 17 – 21 Bottom-rolling
7.0 – 9.0 2 x 3 (bi-parting) 40 – 55 2 x 1,600 13 – 16 Bottom-rolling

Table 7. Folding gate spans. Operator thrust is specified with a 2x margin over the measured rolling resistance.

Wind Load and Automation

A parked folding gate behaves as a solid surface, so wind load is calculated on the full closed area. At 1.0 kPa design pressure a 5 m x 2 m gate sees 10 kN of total load, distributed to three hinge points and the track. Above 1.5 kPa the leaf stiles move from 40 mm to 50 mm and the rollers go to 160 kg. Operators are specified to EN 13241 and EN 12453 with a minimum of two safety devices: a photocell pair and a pressure-sensitive edge, or an encoder-based torque reversal.

Folding Gate Versus Sliding Gate

Criterion Folding gate Sliding gate Choose folding when
Side room required 0.6 – 0.9 m Opening + 0.5 m Side room is under 1.2 m
Opening span 3 – 9 m 3 – 12 m Span is 5 – 9 m on a tight site
Wind capacity Up to 1.5 kPa Up to 2.5 kPa Site is not a cyclonic zone
Track maintenance Higher (more joints) Lower A service contract is in place
Hardware cost index 118 100 Budget allows a higher spec

Table 8. Full sliding and swing gate comparison data is in the perimeter gate reference.

For the comparable sliding and swing data set, see the driveway and perimeter gate data page.

6. Glazing Options and Weight Limits for Folding Doors

Glazing drives both the thermal result and the hardware selection. Adding 4 mm of glass thickness to a 1,000 x 2,700 mm leaf adds about 21 kg, which pushes the roller from 130 kg to 160 kg and the set price up by roughly USD 18-24 per m2.

Double Versus Triple Glazing: Weight and U-Value

Build-up Ug (W/m2K) SHGC Weight (kg/m2) Leaf 1,000×2,700 (kg) Added cost vs DG (USD/m2)
5+12A+5 2.7 0.72 25 88 0
5+12Ar+5 low-E 1.4 0.58 25 88 11 – 15
6+16Ar+6 low-E 1.1 0.55 30 101 18 – 24
6+12Ar+6+12Ar+6 low-E 0.7 0.44 45 148 48 – 62
6+16Ar+6.6.2 laminated low-E 1.0 0.48 36 120 32 – 41

Table 9. Triple glazing returns Ug 0.7 but adds 47 kg to a 1,000 x 2,700 mm leaf, which usually forces a move to bottom-rolling hardware.

SHGC Selection by Climate

Budget rule: if the leaf is above 2,700 mm tall, price the glazing and the hardware together. Triple glazing on a 3,000 mm leaf usually costs more in upgraded rollers and bottom track than the glass itself.

7. Folding Door Pricing: FOB Bands and Landed Cost

All figures below are FOB Foshan or Shenzhen, per square metre of glazed opening, based on a 4-panel 3+1 set of 3,600 x 2,400 mm (8.64 m2) with standard powder coat, 130 kg rollers and double glazed low-E argon. Prices move with order volume, colour, and hardware brand.

FOB Foshan Price Bands by Series

Series Non-thermal break (USD/m2) Thermal break (USD/m2) Triple glazed add (USD/m2) Typical application
FD-70 98 – 128 155 – 205 48 – 62 Residential, mild climate, budget projects
FD-80 118 – 152 185 – 250 48 – 62 Standard residential and townhouse volumes
FD-90 – 225 – 310 52 – 68 Cold climate, exposed sites, villas
FD-110 – 290 – 420 55 – 74 HVHZ, high-rise, passive-house targets

Table 10. Volume bands: 20-99 m2 list, 100-299 m2 less 5%, 300-799 m2 less 9%, 800 m2 and above less 14%.

What Moves the Price

Landed Cost Structure

Cost element USD per m2 Share of landed cost
FOB Foshan (FD-80, 300 m2 tier) 216 23.2%
Ocean freight + insurance 41 4.4%
US customs duty and brokerage 26 2.8%
Domestic drayage and handling 14 1.5%
Local installation labour and materials 634 68.1%
Landed total 931 100%
Local supply-and-install bid (comparison) 1,412 –

Table 11. Landed cost for a 657 m2 order into Seattle. Installation dominates the landed figure, which is why packing and pre-assembly savings matter more than freight negotiation.

8. Certification Map: NFRC, AAMA, CE, AS2047 and Miami-Dade

Certification is market entry, not decoration. A folding door without the right label cannot be submitted for building consent in the target jurisdiction, and retrofitting a test programme after shipment costs more than the order.

Market Required scheme Key metrics Typical result (FD-80)
United States NFRC 100/200 + AAMA/WDMA/CSA 101/I.S.2/A440 U-factor, SHGC, DP rating U-factor 0.30, SHGC 0.28, R-PG50
Florida HVHZ Miami-Dade NOA / Florida Product Approval TAS 201/202/203, +-65 psf Passed with 8.8.4 laminated
Canada NAFS-08 / CSA A440S1 A/B/C class, water penetration R-PG50, air A3, water B7
European Union CE to EN 14351-1 Air, water, wind, Uw, Rw Class 4 / 7A / C4, Uw 2.6
United Kingdom UKCA + Part L / Part Q Uw <= 1.6 W/m2K, security FD-90 with 24 mm break
Australia / NZ AS2047 + NCC Section J N rating, water, ULS, Uw N4, W6 (450 Pa), ULS 2.4 kPa
Germany CE + EnEV / GEG reference Uw <= 1.3 W/m2K FD-110 with 30 mm break

Table 12. Certification route by destination market. Test reports are issued per series and per glazing build-up; changing the glass invalidates the thermal label.

What to Request From the Supplier

Where folding doors are ordered together with the rest of the fenestration, the certification set is shared with the whole-house window and door packages package.

9. Ordering Data: MOQ, Lead Time, Packing and Container Loading

MOQ, Lead Time and Payment

Item Standard value Notes
MOQ 20 m2 per order Sample set of one 3,600 x 2,400 unit accepted at a 35% surcharge
Production lead time 25 – 35 days From approved shop drawing; +8 days for custom colour, +10 for triple glazing
Sample lead time 10 – 14 days Corner section, 400 mm, freight collect
Payment 30% deposit / 70% before shipment Irrevocable L/C at sight accepted above USD 50,000
Warranty 10 years frame, 5 years hardware Coating warranty 10 years under AAMA 2604
Shop drawing 3 – 5 days Two revision rounds included

Table 13. Commercial terms. Prices are held for 30 days from quotation date; aluminium ingot moves beyond 8% trigger a re-quote.

Packing Specification

40HQ Container Loading Math

Series Crates per 40HQ m2 of opening per crate m2 per 40HQ Weight per 40HQ (kg)
FD-70 26 – 28 24 – 27 650 – 730 17,500 – 19,000
FD-80 24 – 26 22 – 25 560 – 650 18,000 – 20,500
FD-90 22 – 24 20 – 23 470 – 550 18,500 – 21,000
FD-110 20 – 22 18 – 21 390 – 460 19,000 – 22,000

Table 14. Loading figures are governed by weight, not volume, above roughly 700 m2. Mixed series loads are accepted from 100 m2 per series.

10. Installation Sequence: Eight Steps and Three Failure Points

Sequence

Step Operation Tolerance / check
1 Verify structural opening and header deflection Header deflection below L/500 under full panel load
2 Set the head track level and shim to the structure 1 mm over the full span, fixings at 400 mm centres
3 Hang panels from the outer end inward Each leaf hung before the next is offered up
4 Set the bottom pivot, then plumb each leaf Leaf plumb within 1.5 mm over 2,400 mm
5 Adjust meeting stile compression 2 – 3 mm gasket compression, latch force below 40 N
6 Fit the external sealant line and sill drainage Neutral-cure silicone, 8 mm x 8 mm bond breaker
7 Fit the traffic door and lock keeps Multi-point lock engages on all points without lift
8 Cycle test 20 full open-close operations No leaf drop, no track marking, no water ingress on hose test

Table 15. Installation sequence. Two installers handle up to a 4-panel set; 5-panel and above needs three.

Three Failure Points

Commissioning Checklist

A step-by-step buyer checklist is also maintained on the folding door selection checklist page.

11. Folding Door Versus Sliding, Lift-and-Slide and French Doors

Criterion Folding door Sliding door Lift-and-slide French door
Clear opening 90 – 95% of span 50% of span 50% of span 85 – 90% of span
Uw (W/m2K) 2.1 – 3.2 1.8 – 2.8 1.4 – 1.9 1.9 – 2.6
Air permeability Class 3 – 4 Class 4 Class 4 Class 4
Watertightness 5A – 9A 7A – 9A 9A – E900 7A – 9A
Max single leaf 1,200 mm wide 1,600 mm wide 3,000 mm wide 900 mm wide
Cost index 100 72 138 84
Hardware service Every 12 months Every 24 months Every 24 months Every 36 months
Best application Wide span, full opening wanted Budget, tight span Very large panel, high thermal target Narrow span, traditional elevation

Table 16. Format comparison on a 4,000 x 2,400 mm reference opening, thermally broken frames, double glazed low-E.

Selection Rules

Equivalent thermal data for a glazed extension is documented in the four-season sunroom thermal data reference.

12. Project Data: 38 Townhouses in Seattle, Washington

Specification: 76 sets of FD-80 folding doors, 3,600 x 2,400 mm, 4-panel 3+1 with traffic door, 6063-T6, 20 mm PA66GF25 break, 6+16Ar+6 low-E (Ug 1.1), AkzoNobel anthracite grey, 130 kg top-hung rollers, flush sill with an external linear drain. Total glazed area 657 m2. Ordered at the 300-799 m2 volume tier.

Cost element Local supply and install China supply + local install Delta
Door system USD 618,000 USD 141,912 -77.0%
Freight, duty, customs included USD 44,022 –
Local installation labour USD 268,000 USD 268,000 0%
Site adjustments and snagging USD 41,684 USD 22,400 -46.3%
Total USD 927,684 USD 476,334 -48.7%
Cost per m2 USD 1,412 USD 725 -48.7%

Table 17. Seattle townhouse project, Q1 2026. Installation labour is identical in both columns; the saving is entirely in the supply line and in reduced snagging because panels arrive factory-glazed.

Measured Outcome

Project figures are from shipped orders and are given as an order-of-magnitude reference. Final pricing depends on configuration, glazing, colour, volume and the destination port.

For Spanish and Latin American market variants of the same folding door platform, including top-hung versus bottom-roll and Chile and Mexico landed costs, see the Spanish and Latin American folding door specifications.