Home > Sunroom > Sunrooms 4 Season Factory in China – Aluminum Sunroom and Conservatory Specs, Pricing
Sunrooms 4 Season Factory in China – Aluminum Sunroom and Conservatory Specs, Pricing
Four-season aluminum sunroom built on 6063-T5 thermally broken frames with 5+12A+5 low-E double glazing – typical configuration for a sunroom attached to house in a heating climate.
A four-season sunroom is a conditioned space, not a screened porch. That single distinction changes every number in the specification: frame U-value, glazing SHGC, roof snow load, condensation control and the HVAC allowance. This page lists the actual profile, glazing and load data a sunrooms 4 season factory in China works to, with FOB price bands by configuration, test standards and container loading math for project buyers.
The difference between a three-season room and a sunrooms 4 season build is that the envelope must carry a heating and cooling load all year. That pushes four parameters above the values used for a seasonal enclosure: frame U-value, glazing U-value, air tightness and roof snow/wind load. If any one of the four is left at seasonal-room level, the result is condensation on the frame in January and an oversized cooling bill in July.
Design loads used for a year-round conditioned sunroom
Load case
Seasonal room
Four-season room
Standard reference
Wind pressure
1.0 – 1.5 kPa
1.5 – 3.0 kPa
EN 12210 / ASCE 7-16
Snow load (roof)
0.75 – 1.0 kPa
1.0 – 2.0 kPa
EN 1991-1-3 / ASCE 7-16
Dead load (roof glazing)
25 – 30 kg/m2
30 – 45 kg/m2
measured, laminated make-up
Air permeability
Class 3 (600 Pa)
Class 4 (600 Pa)
EN 12207
Water tightness
4A (150 Pa)
7A (300 Pa) or E900
EN 12208 / AAMA 501
Thermal transmittance Uw
2.6 – 3.4 W/m2K
1.6 – 2.2 W/m2K
EN ISO 10077-2
Why air tightness class 4 matters more than U-value alone
At Uw 1.8 W/m2K with class 3 air permeability, infiltration adds roughly 0.4 – 0.6 W/m2K of effective heat loss in a 25 km/h wind. Moving to class 4 with a continuous EPDM gasket line and a compression-sealed corner joint recovers that margin without changing the glazing specification. It is the lowest-cost U-value improvement available in a four-season sunroom and it is frequently skipped.
Structure check before quoting: a roof span above 3.6 m on a 45 kg/m2 glazing make-up needs an internal ridge beam or a raised tie. Confirm the beam depth allowance with your engineer before the profile order is locked, because the extrusion die and the beam pocket are made in the same production window.
Aluminum Sunroom Frame Systems: 6063-T5 Profiles and Thermal Breaks
An aluminum sunroom is built from the same extrusion platform as a thermally broken window system, with deeper profiles to carry the roof load. The alloy is 6063 in T5 temper for the frame and T6 for load-bearing mullions and ridge beams. Wall thickness moves from 1.4 mm on a seasonal room to 1.8 – 2.2 mm on a four-season build.
Profile series and measured thermal performance
Series
Depth
Wall
Thermal break
Uf (W/m2K)
Max span
SR-60
60 mm
1.4 mm
PA66GF25 18 mm
3.0
2.4 m
SR-75
75 mm
1.8 mm
PA66GF25 24 mm
2.4
3.0 m
SR-90
90 mm
2.0 mm
PA66GF25 30 mm
2.0
3.6 m
SR-110 (roof)
110 mm
2.2 mm
PA66GF25 34 mm
1.8
4.5 m
Uf is the frame-only value measured by hot-box method to EN ISO 10077-2. The whole-window Uw depends on the glazing unit and the spacer; the figures in the glazing section below use the SR-90 frame as the reference.
Thermal break material: why PA66GF25 and not PVC
PA66GF25 (polyamide 66 with 25% glass fibre) has a coefficient of thermal expansion of 2.3 x 10^-5 /K, close to aluminium at 2.35 x 10^-5 /K, so the composite section does not shear at the knurl interface across a -20 to +60 C cycle.
PVC strips run at 7 – 8 x 10^-5 /K. On a 30 mm break that is a 0.4 – 0.6 mm differential over the same range, which opens a path for air and water at the crimp.
Tensile strength of PA66GF25 is 80 – 130 MPa against 45 – 55 MPa for rigid PVC, so the break carries shear load in a deep mullion rather than acting as a spacer only.
Ask the factory for the polyamide supplier name and the batch glass-fibre content report. Recycled PA66 without fibre is the single most common substitution in low-price sunroom frames.
Surface finish specification
Finish
Film thickness
Salt spray
Colour fastness
Cost adder
Powder coat (polyester)
60 – 80 um
1000 h
Qualicoat Class 1
included
Powder coat (super-durable)
60 – 80 um
1500 h
Qualicoat Class 2
+$4 – 6/m2
PVDF (70% resin)
30 – 40 um
3000 h
AAMA 2605
+$9 – 13/m2
Anodise AA15
15 um
1000 h
AA-M15-C22-A41
+$7 – 10/m2
Wood-grain sublimation
60 um base
1000 h
Qualicoat Class 1
+$12 – 18/m2
Coastal projects within 500 m of the shoreline should be specified at super-durable polyester or PVDF. Standard polyester chalk starts at roughly 18 – 24 months in that exposure band. For related outdoor structures on the same extrusion platform see conservatory and glass house garden buildings.
4 Season Sunroom Glazing: Double vs Triple Low-E, SHGC and Condensation
A 4 season sunroom spends most of its glazing budget on the unit, not the frame. The two numbers that decide whether the room is usable are Ug and SHGC, and they pull in opposite directions depending on whether the site is heating-dominated or cooling-dominated.
Glazing make-up and measured data
Make-up
Ug (W/m2K)
SHGC
LT (%)
Weight (kg/m2)
Adder vs base
5 + 12A + 5 float
2.7
0.72
81
25
base
5 + 12A + 5 low-E
1.4
0.61
78
25
+$8/m2
5 + 16Ar + 5 low-E (warm edge)
1.1
0.58
76
25
+$14/m2
5 + 12Ar + 5 + 12Ar + 5 low-E x2
0.7
0.47
69
37.5
+$38/m2
6 + 1.14 PVB + 6 laminated low-E
1.5
0.52
74
30
+$22/m2
Selecting SHGC by climate
Heating-dominated (HDD above 3000): SHGC 0.60 – 0.70 with low-E on surface 3. The solar gain in winter offsets part of the conduction loss; a high SHGC unit can net 15 – 25 kWh/m2 per heating season of useful gain.
Cooling-dominated or mixed (CDD above 1500): SHGC 0.25 – 0.38 with a solar-control coating on surface 2. This holds west-facing glass surface temperature and cuts peak cooling load by roughly 20 – 30 W/m2 of glazed area.
Roof glazing is a special case. Horizontal glass receives 2 – 3 times the winter beam of vertical glass but also the full summer noon load. Roof units are normally specified at SHGC 0.30 – 0.40 with a laminated inner ply for overhead safety.
Condensation control: the temperature factor route
Condensation on the frame edge is the most common complaint on a four-season sunroom. The check is the temperature factor fRsi = (Tsi – Te) / (Ti – Te). At an interior design of 21 C and 55% RH the dew point is 11.6 C, so fRsi must stay above roughly 0.62 to avoid visible condensation. A 24 mm PA66GF25 break with a warm-edge spacer returns fRsi 0.68 – 0.72 at the glazing bead; an aluminium spacer without a break returns 0.42 – 0.50 and will run water down the frame in a cold snap.
Roof glazing must be laminated to EN 12600 class 1B1 or ANSI Z97.1 for overhead glazing in most jurisdictions. Annealed monolithic glass overhead is not accepted by inspectors in North America, Australia or the EU, regardless of thickness.
Sunrooms and Glass Houses: Roof Configurations and Load Data
Search behaviour around sunrooms and glass houses usually splits into two intents: a year-round living space attached to a house, and a freestanding glazed garden building. Both use the same extrusion family but the roof engineering differs.
Four roof geometries and what they cost
Roof type
Pitch
Span limit
Load
Cost adder / m2
Flat (structural panel)
2 – 5 deg
3.0 m
1.0 – 1.5 kPa snow
+$28 – 40
Lean-to / shed
5 – 20 deg
4.0 m
1.5 – 2.0 kPa snow
+$20 – 30
Gable (glazed both faces)
25 – 40 deg
5.0 m
1.5 – 2.0 kPa snow
+$45 – 70
Hipped / orangery lantern
25 – 35 deg
6.0 m
1.5 – 2.0 kPa snow
+$85 – 130
Insulated roof panel vs glazed roof
A 60 – 100 mm insulated sandwich panel with a 0.022 W/mK core returns Uc 0.20 – 0.30 W/m2K against 1.1 – 1.5 W/m2K for the best double-glazed roof unit. On a 20 m2 roof that is a difference of roughly 380 – 520 W at a 20 K delta.
Glazed roof area above 50% of the roof plan usually pushes the room over the cooling allowance in a mixed climate. The usual fix is a glazed ridge band of 1.0 – 1.5 m with insulated panels on the remainder.
Solar-control coating on the roof plus an internal blind can cut peak summer roof gain by 35 – 45%, which is often cheaper than upsizing the HVAC unit.
Drainage and gutter sizing
A glazed roof sheds to a perimeter gutter. Size the gutter for the local 1-in-100-year rainfall intensity, not the annual average. Rule of thumb used in the shop: 1 cm2 of gutter cross-section per 1 m2 of roof plan area in a 50 mm/h design storm, with an overflow slot above the gutter line so a blocked outlet does not back water into the frame head. For a retractable-roof alternative on the same structure see skylight and retractable roof systems.
Conservatory Insulation: U-Value Targets by Climate Zone
The term conservatory is used across the UK, Ireland, Australia and New Zealand for what North America calls a sunroom. The compliance target is set by the local energy code, and the U-value that passes in one zone will fail in another.
U-value targets and the governing document
Market / zone
Roof U (W/m2K)
Wall/window Uw
Governing document
Typical make-up
UK (England)
0.15 – 0.18
1.4 – 1.6
Approved Document L1B
28 mm triple or panel roof
Ireland
0.16 – 0.20
1.4 – 1.6
TGD L (2021)
28 mm triple or panel roof
France
0.20 – 0.28
1.3 – 1.5
RE2020 (Bbio cap)
24 – 28 mm triple
Germany
0.20 – 0.24
1.1 – 1.3
GEG 2023 / EnEV
28 – 32 mm triple
USA zone 5-6
0.15 – 0.20 (R-30+)
1.7 – 2.0 (U-0.30)
IECC 2021
panel roof + double low-E
Australia zone 6-7
0.30 – 0.40
2.0 – 2.6
NCC 2022 Section J
double low-E, SHGC 0.35
Three ways to hit a 0.18 W/m2K roof
Insulated sandwich panel roof with a 100 mm PIR core: Uc 0.18 – 0.22. Lowest cost per m2 and the fastest to install, but no daylight from above.
Structural glazing with a 40 mm triple unit and two low-E coatings plus krypton fill: Ug 0.6 – 0.7, Uc around 0.9 – 1.1. Does not reach 0.18 without an insulated perimeter or a deeper unit.
Hybrid: insulated panels on 70 – 80% of the roof plan with a glazed ridge band. Returns a whole-roof U around 0.4 – 0.6 and is the configuration most conservatory buyers in the UK and Ireland actually install to get a habitable-room rating.
A conservatory that is classed as a habitable room under building regulations must also meet the glazing safety, ventilation and means-of-escape provisions of the same code, not only the thermal target. Confirm the exemption status with the local authority before the order is placed – in England a conservatory under 30 m2 with a separate external door and independent heating control can remain exempt, but the exemption is lost once the dividing wall is removed. More on the European wintergarten variants is covered in aluminium conservatory specifications.
Sunrooms 4 Season Pricing: FOB China Price Bands
FOB pricing from a sunrooms 4 season factory in China is quoted per square metre of glazed envelope, roof included. The bands below are FOB Shenzhen or Foshan, in USD, at a 2026 Q3 aluminium ingot reference of 2,150 – 2,350 USD/t, and exclude freight, duty and installation.
Configuration
Frame
Glazing
Roof
FOB / m2
Seasonal room, 3-season
SR-60, 1.4 mm
5+12A+5 float
8 mm polycarbonate
$88 – 125
4 season, standard
SR-75, 1.8 mm
5+16Ar+5 low-E
glazed 5+12A+5 lam
$145 – 195
4 season, high-insul
SR-90, 2.0 mm
triple low-E x2
glazed 6+12Ar+6 lam
$210 – 268
Conservatory, hybrid roof
SR-90, 2.0 mm
triple low-E
100 mm panel + ridge band
$232 – 310
Orangery / lantern
SR-110, 2.2 mm
triple low-E
structural lantern
$295 – 385
Cost drivers that move the quote
Aluminium ingot price: a 100 USD/t move changes frame cost by roughly 1.8 – 2.4 USD/m2 on a standard 4 season build. Quotes are normally held for 30 days.
Coating: PVDF adds 9 – 13 USD/m2, wood-grain sublimation 12 – 18 USD/m2 over standard polyester.
Glazing area ratio: a unit with 80% glass costs more per m2 than one with 60%, because glass and labour scale faster than frame.
Roof type: gable and lantern roofs add 45 – 130 USD/m2 over a lean-to on the same footprint.
Quantity: 30 – 100 m2 is the base band; 300 – 800 m2 typically prices 7 – 11% lower; above 2,000 m2 the discount reaches 13 – 16%.
Landed cost example: 20 m2 four-season unit, standard specification
Cost line
Basis
Amount (USD)
FOB value
20 m2 x $170
$3,400
Ocean freight + THC
6.5 m3 LCL, Shenzhen – Hamburg
$780 – 1,050
Insurance
0.35% of CIF
$15 – 20
Import duty (EU aluminium)
6.0% of CIF
$250 – 270
Inland delivery
port – site, 320 km
$240 – 330
Installation labour
2 fitters x 3 days
$1,500 – 2,400
Landed total
$6,185 – 7,470
Landed per m2
$309 – 374 / m2
Above roughly 35 – 40 m2 of envelope a 20GP container becomes cheaper than LCL on a per-m2 basis, and the glass breakage rate drops because the crates are not transhipped. A 20GP takes about 55 – 65 m2 of four-season envelope in knockdown crates; a 40HQ takes 125 – 145 m2.
Certification and Test Data for Four-Season Sunrooms
Test reports are what separate a quotation from a claim. The reports below are the ones project buyers in the EU, UK, US and Australia ask for, with the acceptance threshold each one carries.
Standard
Property
Typical result
Market
EN 14351-1
CE marking, whole product
System 3, DoP issued
EU / EEA
EN 12207
Air permeability
Class 4 (600 Pa)
EU / UK
EN 12208
Water tightness
Class 7A (300 Pa)
EU / UK
EN 12210
Wind resistance
Class C4 / B4
EU / UK
NFRC 100/200
U-factor / SHGC
U 0.28 – 0.33, SHGC 0.30 – 0.58
USA
AAMA / WDMA / CSA 101/I.S.2/A440
NAFS performance grade
CW-PG50 / AW-PG65
USA / Canada
AS 2047
Window performance
N4 / C4 / W4
Australia / NZ
ISO 9001 / 14001
Quality and environmental system
Annual surveillance audit
All
What to request from the factory
The Declaration of Performance with the system number, not a generic certificate. The DoP must name the profile series and glazing make-up actually being shipped.
The test report number and the issuing laboratory. EN test reports are valid for five years or until the profile changes, whichever is shorter.
For North America: the NFRC label certificate and CMA (Component Modelling Approach) sheets, plus the NAFS grade. A supplier without a CMA number cannot issue a legal NFRC label.
For the UK: the UKCA or CE declaration with the approved body number where applicable, and confirm the glazing safety class to BS EN 12600.
The same documentation set applies to the window and door packages that usually ship with a sunroom order; see whole-house windows and doors procurement for the accessory and hardware documentation that accompanies it.
Procurement Data: MOQ, Lead Time, Payment, Packing
Commercial terms
Item
Standard term
Notes
MOQ
30 m2 per model
Mixed models allowed above 80 m2 total
Sample
1 corner section or 1.2 m2 unit
Charged, credited against the first order
Lead time (production)
28 – 35 days
From approved shop drawing and deposit
Lead time (PVDF / wood grain)
+7 – 10 days
Coating line scheduling
Sea freight
25 – 38 days
Shenzhen / Nansha to EU west or US west
Payment
30% deposit, 70% before shipment
L/C at sight accepted above USD 30,000
Warranty
10 years frame, 5 years hardware
Coating: 10 – 15 years by finish
Packing specification
Frame: individual PE sleeve plus EPE foam wrap, bundled in a plywood-crated or steel-strapped pack. Corner protectors on all visible faces.
Glass: vertical A-frame crate with 10 mm rubber separators, fumigated plywood, max 1.8 t per crate for manual unloading at site.
Hardware: cartons inside the frame crate, with the packing list duplicated outside in a waterproof sleeve.
Typical volume: 0.30 – 0.34 m3 per m2 of four-season envelope in knockdown crates.
Container loading math
Container
Usable volume
Envelope load
Break-even vs LCL
20GP
28 m3
55 – 65 m2
above ~38 m2
40GP
58 m3
110 – 125 m2
above ~85 m2
40HQ
68 m3
125 – 145 m2
above ~100 m2
Installation Sequence for a Sunroom Attached to House
Most four-season sunroom defects are installation defects, not manufacturing defects. The sequence below is the one used on a slab-on-grade attachment and assumes the foundation and any required permit are already in place.
Nine-step sequence
1. Set the base: level the sill track on a 10 – 15 mm shim bed, check square within 2 mm over 3 m, and fix with M10 stainless anchors at 600 mm centres.
2. Run the sill flashing: a continuous EPDM or butyl flashing dressed up the house wall and over the outer face of the sill before any frame is stood.
3. Dry-assemble the frame: stand corner posts and mullions, brace, and re-check diagonal before final fixing. Do not fix the glazing until the frame is square.
4. Build the roof structure: ridge beam first, then rafters, then the glazing bars. Torque the structural bolts to the shop-drawing value, typically 25 – 35 Nm for M10.
5. Glaze from the bottom up, setting blocks at quarter points, and fit the gasket on the weather side first.
6. Seal the perimeter: backer rod plus a neutral-cure silicone to a 6 – 8 mm joint, tooled within 10 minutes. Do not use acetic-cure silicone on powder-coated aluminium.
7. Fit the gutter and downpipe, then water-test the roof with a hose at 10 L/min for 15 minutes per 3 m of gutter run before closing the ceiling.
8. Commission the opening sashes: adjust the hinge and keep to a 1.5 – 2.0 kg operating force, and confirm the lock engages without lifting the sash.
9. Hand over with the DoP, the glazing safety certificates, the coating warranty and a maintenance schedule for gasket and drainage.
Three failure points to inspect
The head junction to the house wall. Most leaks appear here, not in the roof. A two-stage joint with a drained cavity behind the outer seal is the reliable detail.
The base sill. If the shim bed is not continuous, the sill deflects under the roof load and the corner joints open.
The gutter outlet. A single outlet on a 20 m2 roof will overflow in a design storm. Size two outlets or add an overflow weir.
Where the sunroom replaces an existing glazed wall, the interface is usually handled with a sliding or folding door system rather than a fixed screen; see aluminum sliding patio door specifications for the track and threshold details that pair with a sunroom opening.
A developer in southern Ontario ordered 22 identical four-season units across a 22-house subdivision in 2025. Design condition was -21 C winter, 31 C summer, ground snow load 1.9 kPa, wind 1.4 kPa at 10 m.
Specification shipped
Component
Specification
Reason
Frame
SR-90, 2.0 mm, PA66GF25 30 mm
Uf 2.0, fRsi above 0.65 at -21 C
Glazing (vertical)
5 + 16Ar + 5 low-E, surface 3
Uw 1.7, SHGC 0.61 for winter gain
Glazing (roof)
6 + 12Ar + 6 lam low-E, SHGC 0.36
Overhead safety + summer roof load
Roof
Gable, 30 deg, 4.2 m span, ridge beam
Snow 1.9 kPa with 0.9 m rafter spacing
Finish
Super-durable polyester, RAL 7016
Class 2, freeze-thaw and road salt exposure
Envelope per unit
18.5 m2
6.2 m x 3.0 m footprint
Cost comparison
Line
Local supplier quote
China landed
Delta
Envelope supply, 22 units
CAD 512,600
CAD 208,400
-59.3%
Freight, duty, brokerage
included
CAD 41,900
+8.2% of FOB
Installation labour
CAD 158,400
CAD 168,200
+6.2%
Engineering / permit support
CAD 24,000
CAD 11,500
-52.1%
Total, 22 units
CAD 695,000
CAD 430,000
-38.1%
Per m2 of envelope
CAD 1,707
CAD 1,056
-38.1%
Installation ran 6.2% higher because the crates were unloaded and staged per house rather than delivered as one drop, which added 0.7 days per unit. Net saving per house was about CAD 12,000. Condensation inspection at the first winter cycle recorded no frame-edge condensation at -18 C interior 21 C / 40% RH, which was the acceptance criterion written into the contract.
Snow load is the parameter that most often breaks a sunroom order imported from a low-snow region. Declare the ground snow load, the importance factor and the exposure category at enquiry stage so the ridge beam and rafter spacing are sized once, not twice.
Aluminum vs uPVC vs Timber for a Four-Season Sunroom
Property
Aluminium (thermally broken)
uPVC (multi-chamber)
Engineered timber
Uf (W/m2K)
1.8 – 2.4
1.2 – 1.6
1.3 – 1.8
Max unsupported span
4.5 m
2.4 m
3.0 m
Frame depth for same span
90 – 110 mm
140 – 180 mm
110 – 140 mm
Thermal expansion (/K)
2.3 x 10^-5
7.0 x 10^-5
4.0 x 10^-5 (across grain)
Coastal salt resistance
High with PVDF
Moderate
Low without maintenance
Fire rating
A1 non-combustible
B-s1 self-extinguishing
D combustible
Maintenance cycle
10 years (gasket)
15 years (gasket, seals)
3 – 5 years (coating)
Recycled content
60 – 75% typical
10 – 30%
0 – 5%
FOB / m2
$145 – 310
$110 – 220
$230 – 420
Where each material wins
Aluminium: spans above 3.0 m, coastal or high-wind exposure, projects with a non-combustible cladding requirement, and any roof with a lantern or structural glazing ridge.
uPVC: heating-dominated inland sites with short spans and a tight budget. The wider frame section reduces glass area by 8 – 12% on the same opening, which offsets part of the lower Uf in a solar-gain calculation.
Timber: heritage or conservation-area projects where the local authority requires a timber sightline. The maintenance cycle and the FOB price both argue against it for volume builds.
To price a four-season sunroom, send the plan dimensions, roof type, ground snow load, wind pressure, U-value target and the destination port. A shop drawing set including the ridge beam sizing and the glazing schedule is returned with the quotation, normally within three working days. See also four-season aluminum sunroom wholesale specifications and solarium and glass room builds.