Blog

Home   >   Exterior Doors   >   Front Entry Doors Factory in Foshan China – Entry Doors for Houses, Modern Front Doors and Exterior Entry Door Specs with FOB Pricing

Front Entry Doors Factory in Foshan China – Entry Doors for Houses, Modern Front Doors and Exterior Entry Door Specs with FOB Pricing

Aluminum front entry doors installed on a modern residential house in China - thermal break entry door with vertical glazed sidelight and flush threshold
Thermal-break aluminum front entry door with a vertical glazed sidelight and flush threshold, installed on a residential entrance.
A front entry door is the primary exterior door leaf on a dwelling. In the China export program the standard build is a thermally broken aluminum leaf, 40-70 mm thick, carrying an insulated glazing unit or a composite panel, hung on a matched aluminum frame with a multipoint lock. This article documents the construction, the size matrices used in the United States, United Kingdom, European Union and Australian markets, the hardware standards that govern locking, the coating specifications, the certification route for each destination, the production sequence, FOB price tables in USD, landed cost arithmetic, installation method, and delivered project data. All figures come from export production in Foshan, Guangdong.
FOB price
$118-580/m²
Ud value
1.1-3.4 W/m²K
Profile wall
1.4 / 1.8 / 2.0 mm
MOQ
20 sets / model
Lead time
25-35 days
Contents
1. Front Entry Door Anatomy
2. Entry Doors for Houses: Sizes and Handing
3. Front Doors for Houses Modern: Panel Layouts
4. Modern Front Doors: Finish Systems
5. Exterior Entry Doors: Air, Water, Wind, Ud
6. Hardware and Locking Standards
7. Alloy, Temper and Wall Thickness
8. Thermal Break and Ud Calculation
9. Glazing and Safety Glass
10. Certifications by Market
11. Production Process
12. Quality Control and Testing
13. FOB Price Tables (USD)
14. Landed Cost Model
15. MOQ, Lead Time and Packaging
16. Installation and Waterproofing
17. Case Study: Texas Townhouse Project
18. Material Comparison
19. Selection by Project Type
20. RFQ Checklist
21. Glossary
22. Related Products

Front Entry Door Anatomy: Leaf, Frame, Threshold and Hardware

A complete entry door assembly is a set of five component groups. Quoting each group separately is what makes a China factory quote comparable with a domestic one.

The Five Component Groups

Leaf Core Options and Their Thermal Effect

The core determines most of the Ud number and a large part of the leaf weight. Four cores are in regular production.

Core type Density (kg/m³) Thermal conductivity (W/mK) Typical leaf weight (900×2100 mm) Cost adder (USD/m²)
Polyurethane foam (PU) 40-60 0.024 24-30 kg $0 (baseline)
Aluminum honeycomb 30-45 0.310 (through cells) 18-22 kg $6-11
Rock wool 60-120 0.038 34-42 kg $9-16
XPS board 30-40 0.034 22-28 kg $4-8

PU foam is the default for thermally broken leaves. Honeycomb is specified where the leaf must stay light for tall formats above 2.4 m. Rock wool is used where a 30-60 minute fire rating is required, because it holds integrity at temperature while PU does not.

Skin Thickness and Dent Resistance

Door skins are rolled from 3003-H14 or 5005-H34 sheet for paint-grade faces. Thickness selection follows traffic class: 1.0 mm for residential single dwellings, 1.2 mm for multi-unit entries, 1.5-2.0 mm for commercial or public entries. A 1.0 mm skin deflects 1.8-2.4 mm under a 200 N point load at mid-span of a 500 mm panel; a 1.5 mm skin deflects 0.7-0.9 mm under the same load.

Entry Doors for Houses: Size Matrices, Handing and Rough Openings

Entry doors for houses follow four different national size families. Ordering the wrong family is the single most common cause of a rejected shipment, so the matrix below is the first thing to confirm on a shop drawing.

Nominal Leaf Sizes by Market

Market Nominal leaf size Metric equivalent (mm) Typical frame depth Rough opening (mm)
United States 36 x 80 in 914 x 2032 75 / 100 mm 978 x 2083
United States (tall) 36 x 96 in 914 x 2438 100 mm 978 x 2489
United Kingdom 33 x 78 in 838 x 1981 70 / 75 mm 898 x 2031
European Union 900 x 2000 900 x 2000 75 / 85 mm 960 x 2050
European Union (tall) 1000 x 2100 1000 x 2100 85 mm 1060 x 2150
Australia 820 x 2040 820 x 2040 75 / 100 mm 880 x 2090
Australia (tall) 920 x 2340 920 x 2340 100 mm 980 x 2390

Rough opening values above assume a 10-12 mm shim gap per side and a 10 mm head gap. For a blockwork or masonry reveal, add 10 mm to both width and height; for a timber stud reveal, the nominal opening equals the frame plus 20 mm.

Handing: Left, Right, Inswing and Outswing

Handing is stated from the outside face of the building. An inswing leaf opens into the dwelling and puts the hinges on the interior, which protects the hinge pins from weather and attack but consumes 40-60 mm of hallway space. An outswing leaf keeps the interior floor clear and is required in some coastal wind zones, because positive design pressure pushes the leaf against its rebate instead of against the lock. Specify the handing on the shop drawing with a plan symbol, not with a written description: about 3 percent of rework orders in the Foshan export program trace back to a text-only handing note.

Sidelights, Transoms and Combinations

Front Doors for Houses Modern: Panel Layouts and Glazing Ratios

Front doors for houses modern in this category are flat-panel leaves with a glazed insert. The layout is set at the design stage and fixes the glass area, which in turn drives the Ud number and the price.

Six Standard Layouts

Layout code Description Glazed area of a 900×2100 leaf Ud with 24 mm break, Low-E DG Layout adder
FL-01 Full flush panel, no glazing 0 % 1.42 W/m²K $0
FL-02 Small square insert, upper third 11 % 1.51 W/m²K $18-32
FL-03 Vertical full-height strip 19 % 1.58 W/m²K $28-48
FL-04 Two vertical strips 27 % 1.66 W/m²K $42-68
FL-05 Horizontal band, upper quarter 22 % 1.61 W/m²K $34-56
FL-06 Full glazed leaf 72 % 1.92 W/m²K $85-140

The Ud penalty for glazing is smaller than most buyers expect, because a modern Low-E double unit at Ug 1.1 W/m²K is close to the panel Ud of 0.9-1.1 W/m²K. Going from FL-01 to FL-06 costs about 0.50 W/m²K. Where a code path sets a hard Ud limit, a wide thermal break recovers it: the same FL-06 leaf on a 34 mm break with triple glazing lands at 1.14 W/m²K.

Glazing Ratio and Daylight

A full glazed leaf (FL-06) with 5 mm Low-E glass transmits 68-72 percent of visible light. Measured on a 1.9 m² leaf, that is 1.29-1.37 m² of effective glazing, which is enough to light a 12-16 m² entrance hall to 150-220 lux on an overcast day. A vertical strip (FL-03) at 19 percent gives 0.36 m² of effective glazing and 45-70 lux, which reads as a lit threshold rather than a lit hall.

Panel Relief Options

Modern Front Doors: Powder Coating, PVDF and Anodizing Specifications

Modern front doors are specified by coating standard rather than by colour name. The standard fixes film thickness, salt spray hours and gloss retention, and it is the clause an inspector will check.

AAMA 2603 / 2604 / 2605 and Qualicoat

Specification Minimum film (μm) Salt spray (ASTM B117) South Florida exposure Typical use Adder (USD/m²)
AAMA 2603 20 1,000 h 1 year Interior doors, dry climates $0
AAMA 2604 30 3,000 h 5 years Standard exterior entry doors $5-9
AAMA 2605 30 (70 % PVDF resin) 4,000 h humidity + 4,000 h salt 10 years Coastal, high UV, dark colours $11-18
Qualicoat Class 1 60 1,000 h 1 year EU projects, EN 12206-1 route $0
Qualicoat Class 2 (Seaside) 60 + pre-anodising 2,000 h 5 years EU coastal projects $7-12
Anodised AA20 (AAMA 611 Class I) 20 (oxide) n/a – sealed oxide 5 years Metallic finishes, high traffic $9-15

Dark colours are the practical reason to move up a class. A 9011 graphite black powder at AAMA 2604 reaches 78-84 degrees Celsius surface temperature in summer sun in a subtropical climate, which accelerates chalking; the same colour at AAMA 2605 keeps 90 percent gloss after 5 years of Florida exposure versus 60-65 percent at 2604.

Wood Grain Sublimation

Sublimation transfer puts a 20-40 μm wood-grain layer over the powder base. The film is applied under vacuum at 190-205 degrees Celsius for 8-10 minutes, and the grain penetrates the coating rather than sitting on it. Oak, walnut, teak and eucalyptus patterns are stocked. Wood grain adds $12-20/m² and carries the same warranty as the underlying powder class. It is the standard answer when a planning authority requires a timber appearance on an aluminum body.

Colour Range and Lead Time Impact

Exterior Entry Doors: Air, Water, Wind and Thermal Test Data

Exterior entry doors are classified by three independent test results plus the whole-door thermal transmittance. The values below are factory test data on a 1000 x 2200 mm single leaf in a 75 mm frame.

EN 12207 Air Permeability, EN 12208 Water Tightness, EN 12210 Wind Resistance

Build tier Air permeability (EN 12207) Water tightness (EN 12208) Wind resistance (EN 12210) Cyclic wind (EN 12211)
Standard, 2 gaskets Class 3 (600 Pa, 6.0 m³/h·m²) Class 4A (150 Pa) C3 / 1,200 Pa 50 cycles at 720 Pa
Mid, 3 gaskets + drop seal Class 4 (600 Pa, 1.5 m³/h·m²) Class 7A (300 Pa) C4 / 1,600 Pa 50 cycles at 960 Pa
Premium, 3 gaskets + rebated threshold Class 4 (600 Pa, 0.8 m³/h·m²) Class 8A (450 Pa) C5 / 2,000 Pa 50 cycles at 1,200 Pa
Impact / NOA build Class 4 (600 Pa, 1.0 m³/h·m²) Class 9A (600 Pa) C5 / 2,400 Pa TAS 203: 9,000 cycles
A reading of Class 7B under EN 12208 is not lower than 7A – it means the door was tested unprotected and reached 300 Pa. Class 7A means the same 300 Pa was reached with the door protected by an external screen or reveal. Doors without a porch or canopy should be specified to the B classification, because the B number is the one that applies once installed.

Design Pressure for North American and Australian Destinations

Destination / standard Performance class Design pressure Water test pressure Air infiltration limit
NAFS-11 R (residential) R-PG25 ±1,200 Pa (25 psf) 180 Pa (3.75 psf) 1.5 L/s·m²
NAFS-11 LC (light commercial) LC-PG40 ±1,900 Pa (40 psf) 290 Pa (6.0 psf) 1.5 L/s·m²
NAFS-11 CW (commercial) CW-PG50 ±2,400 Pa (50 psf) 360 Pa (7.5 psf) 1.5 L/s·m²
Miami-Dade HVHZ Large missile ±3,350 Pa (70 psf) TAS 202 + 203 ASTM E283
AS 2047 (Australia) N3 N3 ±1,000 Pa 300 Pa 5.0 L/s·m²
AS 2047 (Australia) N5 N5 ±2,000 Pa 450 Pa 5.0 L/s·m²

Whole-Door Ud Values by Configuration

Thermal break Glazing Panel core Ud (W/m²K) Applies to
None 5 + 12A + 5 clear PU 40 kg/m³ 3.10 – 3.40 Interior faces, garages
14.8 mm PA66GF25 5 + 12A + 5 clear PU 40 kg/m³ 2.20 – 2.40 Warm climates, no code limit
20 mm PA66GF25 5 Low-E + 16Ar + 5 PU 45 kg/m³ 1.72 – 1.88 US IECC zones 3-4
24 mm PA66GF25 5 Low-E + 16Ar + 5 PU 45 kg/m³ 1.55 – 1.70 US IECC zones 4-5, UK Part L
30 mm PA66GF25 5 Low-E + 12Ar + 5 + 12Ar + 5 PU 55 kg/m³ 1.22 – 1.34 US zones 6-7, EU retrofit
34 mm PA66GF25 + foamed cavity Triple Low-E, 2 x argon Rock wool 90 kg/m³ 0.95 – 1.12 Passive house component, EU new build

Ud is calculated to EN ISO 10077-1 or simulated to NFRC 100 for the North American market. The two methods give different numbers for the same door – NFRC uses a fixed 1,000 x 2,000 mm residential door size and different boundary conditions, and typically reports 0.05-0.12 W/m²K lower than the EN method on the same assembly.

Front Entry Door Hardware: Hinge, Lock and Closer Standards

Hardware is where an entry door either meets the local security standard or fails it. Six product standards cover the components.

Locking Standards: ANSI/BHMA and EN

Component US standard EU standard Grade to specify Test duty
Mortise lock ANSI/BHMA A156.13 EN 12209 Grade 1 / EN 12209 Grade 6 1,000,000 cycles (Gr 1) / 200,000 (EN 6)
Bored / cylindrical lock ANSI/BHMA A156.2 EN 12209 Grade 1 / Grade 6 800,000 / 200,000 cycles
Multipoint lock ANSI/BHMA A156.36 EN 15685 Grade 1 / Grade 5 300,000 cycles
Cylinder ANSI/BHMA A156.5 EN 1303 Grade 1 / 3-star (EN 1303:2015) Drill, pick, bump, snap resistance
Lever handle / furniture ANSI/BHMA A156.13 EN 1906 Grade 1 / Category of use 4 200,000 cycles (EN 1906 grade 7)
Single-axis hinge ANSI/BHMA A156.1 EN 1935 Grade 1 / Grade 13 (160 kg) 200,000 cycles
Door closer ANSI/BHMA A156.4 EN 1154 Grade 1 / EN power size 3-5 500,000 cycles (Gr 1) / 500,000 (EN)

Multipoint Locking and Burglar Resistance

A multipoint lock engages the frame at three or more points from a single handle throw. The configurations in production are:

For UK projects, PAS 24:2022 is the enhanced-security document referenced by Approved Document Q. It is an assembly test that includes manual attack with a screwdriver, shim, knife and the specified tool set for 3 minutes of attack time, plus a 6 N·m cylinder torque test and a 1,000 N lever load in each direction. Certification to PAS 24 is a prerequisite for the Secured by Design police mark; the factory holds test evidence for the exterior security door range and applies the same hardware set to entry doors.

Hinge Count, Load Rating and Corrosion

Hinge quantity follows leaf height and weight: two hinges to 2,000 mm, three to 2,400 mm, four above 2,400 mm or above 60 kg. EN 1935 grade 11 carries 120 kg, grade 13 carries 160 kg, grade 14 carries 200 kg on three hinges. Corrosion resistance is stated to EN 1670 on a 1-5 scale; grade 4 (240 h neutral salt spray) is the minimum for an exposed exterior face and grade 5 (480 h) is specified within 5 km of a coastline. Hinges on outswing leaves must be non-removable-pin or fitted with security studs, otherwise the leaf can be lifted off from the outside.

Electronic Access and Smart Locks

Aluminum Alloy, Temper and Profile Wall Thickness

Entry door profiles are extruded from the 6xxx series. The alloy and temper set the mechanical properties, and the wall thickness sets how large a leaf can be built without deflection.

Alloy and Temper Mechanical Properties (EN 755-2)

Alloy and temper Tensile strength Rm (MPa) Yield Rp0.2 (MPa) Elongation (%) Where used in an entry door
6060-T66 215 160 8 Thin-wall decorative trim, glazing beads
6063-T5 160 110 8 Standard stiles, rails, frame profiles
6063-T6 205 180 8 Reinforced stiles on leaves above 2.4 m
6061-T6 260 240 8 Hinge reinforcement plates, heavy threshold bodies
6082-T6 310 260 10 Structural mullions in coupled sidelight runs
3003-H14 (sheet) 150 120 5 Door skins, 1.0-2.0 mm
5005-H34 (sheet) 170 150 5 Anodising-grade door skins

Billets are primary aluminum to GB/T 1196 with a mill certificate giving the heat number; each extrusion batch is traceable to the billet cast. Secondary alloy is used only on non-structural trim and is declared on the order if requested.

Wall Thickness Selection by Leaf Size

Profile wall Max leaf height (single) Max leaf width (single) Wind class ceiling Relative cost
1.4 mm 2,100 mm 950 mm EN 12210 C3 baseline
1.6 mm 2,300 mm 1,000 mm EN 12210 C3/C4 + 6 %
1.8 mm 2,500 mm 1,100 mm EN 12210 C4 + 13 %
2.0 mm 2,700 mm 1,200 mm EN 12210 C5 + 21 %
2.2 mm 3,000 mm 1,200 mm EN 12210 C5 / AW class + 30 %

Wall thickness is measured on the main load-bearing chamber with an ultrasonic gauge at three points per profile length. GB/T 5237.1 allows a -0.05 mm tolerance on a nominal 1.4 mm wall; buyers shipping to a market with a mandatory minimum (for example 1.4 mm for residential doors in several Australian states) should specify the nominal plus tolerance explicitly on the drawing.

Deflection Check for a Tall Leaf

For a 1,100 x 2,600 mm leaf on 1.8 mm wall under 1,600 Pa design pressure, the stile behaves as a simply supported beam on hinges 2,200 mm apart. Second moment of area for the stile section is about 22.4 x 10⁴ mm⁴; elastic modulus of aluminum is 70,000 MPa. Mid-span deflection works out at about 9.6 mm, which is L/229 and inside the L/200 limit that most standards apply to door leaves under design pressure. At 2.0 mm wall the same leaf deflects 7.9 mm (L/278).

Thermal Break: Strip Material, Width and Ud Arithmetic

The thermal break is the polyamide strip that separates the inner and outer aluminum halves. It is the single component that decides whether a door can meet an energy code.

PA66GF25 Strip Specification

Worked Ud Calculation (EN ISO 10077-1)

For a 1,000 x 2,200 mm leaf on a 24 mm break with a 5 Low-E + 16Ar + 5 glazed insert at 27 percent glazed area, the calculation runs:

Term Symbol Value Note
Door leaf area Ad 2.20 m² 1,000 x 2,200 mm
Frame area Af 0.68 m² Perimeter x 100 mm visible width
Panel area Ap 1.61 m² Leaf minus glazing
Glazing area Ag 0.59 m² 27 percent of leaf
Glazing perimeter lg 3.26 m Linear thermal transmittance path
Panel U-value Up 1.05 W/m²K 45 kg/m³ PU core, measured
Frame U-value Uf 2.10 W/m²K 24 mm break, 75 mm depth
Glazing U-value Ug 1.10 W/m²K 5 Low-E + 16Ar + 5, EN 673
Spacer psi Ψg 0.040 W/mK Warm-edge spacer
Result Ud Ud 1.44 W/m²K Area-weighted, EN ISO 10077-1

Substituting an aluminium spacer for the warm-edge spacer moves Ψg from 0.040 to 0.068 W/mK and raises Ud from 1.44 to 1.49 W/m²K. The warm-edge spacer costs $4-7 per door and is the cheapest single thermal upgrade available.

Breaking the Frame Bridge at the Threshold

The threshold is the most common thermal weak point and the most common condensation complaint. A solid aluminium threshold on a broken frame creates a direct metal path from outside to inside; surface temperature on the inner face drops to 8-11 degrees Celsius in a 5 degree Celsius exterior with 20 degrees Celsius interior at 50 percent relative humidity, which is below the 12.6 degrees Celsius dew point. A thermally broken threshold with a polyamide insert raises the inner face to 15-17 degrees Celsius and removes the condensation. The adder is $26-48 per set and it should be treated as mandatory in heating climates.

Condensation Resistance Check

EN ISO 13788 gives the temperature factor fRsi = (θsi – θe) / (θi – θe). At 20 degrees Celsius interior, 0 degrees Celsius exterior and 50 percent relative humidity, the minimum fRsi to avoid surface condensation is 0.52. A non-broken threshold returns fRsi 0.42-0.48. A 24 mm break with a broken threshold returns fRsi 0.58-0.64. A 34 mm break with foamed cavities and a broken threshold returns fRsi 0.68-0.74, which is the range required for mould-free operation at 60 percent relative humidity.

Glazing and Safety Glass: Build-Ups, Standards and Acoustic Data

Any glazed area in a door is safety glass by regulation in every market covered here. The build-up then sets Ug, Rw, light transmittance and solar gain.

Glazing Build-Ups and Performance

Build-up Ug (W/m²K) Rw (dB) Light transmittance SHGC Weight (kg/m²)
5 + 12A + 5 clear 2.70 30 0.78 0.72 25
5 Low-E + 16Ar + 5 1.10 31 0.71 0.58 25
6 Low-E + 16Ar + 6 1.10 33 0.70 0.57 30
5 + 12A + 6.38 laminated 2.60 36 0.76 0.62 32
6.38 Low-E laminated + 16Ar + 6 1.10 38 0.68 0.49 38
5 Low-E + 12Ar + 5 + 12Ar + 5 0.60 34 0.62 0.45 37
6 + 12A + 6 (impact, HVHZ) 2.60 35 0.75 0.55 36

Safety Glass Standards

Tempered glass carries a permanent ceramic-frit mark in a corner giving the standard, the manufacturer and the plant code. An unmarked pane in a door leaf is a compliance failure in every market listed and is grounds for rejection at inspection.

Decorative and Functional Glass Options

Front Entry Door Certifications by Destination Market

The certification route is set by the destination, not by the factory. Ordering the wrong route is expensive because the test is done on the finished assembly.

European Union: CE Marking Under EN 14351-1

External pedestrian doorsets fall under EN 14351-1 with AVCP system 3. The declared characteristics are: resistance to wind load, resistance to static torsion, operating forces, safe opening and closing, mechanical strength, thermal transmittance (Ud), air permeability, water tightness, radiation properties (g value and light transmittance), and, where relevant, acoustic performance and burglar resistance. The factory issues a Declaration of Performance with the DoP number printed on the frame label and on the leaf hinge-side edge.

United Kingdom: UKCA / CE, PAS 24 and Approved Document Q

Requirement Document What is tested Typical result on the mid build
Security – new dwellings PAS 24:2022 3 min manual attack + cylinder torque + lever load Pass
Security – police mark Secured by Design PAS 24 plus licensed manufacturer audit Pass on the specified hardware set
Thermal – Part L 2021 EN ISO 10077-1 / BFRC Ud calculation 1.6 W/m²K (limit 1.4 for doors)
Safety glass EN 12600 Pendulum impact 1B1
Fire – flats EN 16034 / BS 476-22 Integrity and insulation FD30 with rock wool core and intumescent
The Part L 2021 limiting Ud for a door with more than 60 percent glazing is 1.4 W/m²K. The standard mid build at 1.55-1.70 W/m²K does not meet it. The compliant route is a 30 mm thermal break with triple glazing (1.22-1.34 W/m²K) or a reduced glazed area on a 24 mm break. This single constraint is the reason UK orders skew toward 30 mm and 34 mm breaks.

United States: NAFS, NFRC and the HVHZ Route

Australia, Middle East and Other Destinations

For projects that need a fire rating on an apartment entry door, the standard is EN 16034 with EN 14351-2, giving EI30 or EI60. The build differs substantially: rock wool core, intumescent strips in the rebate, a fire-rated glazing unit and a tested closer. Fire-rated leaves run $310-540 per set and require the certificate to list the exact hardware. Reference the steel versus aluminum exterior door comparison for the cost and performance trade-off on fire-rated entrance doors.

Production Process: Extrusion to Crating in Twelve Operations

A Foshan entry door line runs twelve operations. Nine are mechanised, three are manual assembly and adjustment.

Operations 1-6: Profile and Surface

  1. Extrusion – billet heated to 480-520 degrees Celsius, pressed at 12-18 m/min through a hardened steel die. Die life is 40-60 tonnes of profile.
  2. Ageing – artificial ageing at 195 degrees Celsius for 4 h (6063-T5) or 6 h (6063-T6) to reach the specified temper.
  3. Cutting – double-head saw to length at ±0.2 mm; stiles and rails cut in pairs to keep the leaf square.
  4. Thermal break insertion – roll-in on the polyamide strip at 230-250 degrees Celsius, followed by a mechanical crimp test at 80 N/mm sample pull.
  5. Surface pre-treatment – chrome-free conversion or, for seaside class, anodic pre-treatment to 3-5 μm before powder.
  6. Coating – electrostatic powder at 60-80 kV, film built to 60-120 μm depending on class, cured at 195-205 degrees Celsius for 12-15 min in a gas-fired oven; PVDF at 30-40 μm cured at 230-240 degrees Celsius.

Operations 7-12: Machining and Assembly

  1. CNC machining – 4-axis centre cuts hinge pockets, lock mortices, cylinder holes and drainage slots at ±0.1 mm. Drainage slots are cut on a 5 degree inward slope.
  2. Core bonding – the two skins and the core are laid in a hydraulic press at 0.8-1.2 MPa for 25-40 min with a two-component polyurethane adhesive. Press time is the longest single operation in the leaf build.
  3. Frame assembly – corner keys inserted, corners crimped on a four-head press, then injected with two-component epoxy through the key-way. Shear strength on an epoxied corner reaches 2,400-2,800 N versus 900-1,200 N on a crimped-only corner.
  4. Glazing – setting blocks at quarter points, spacer shims, then structural glazing tape or a wet-sealed wedge gasket depending on the specified water class.
  5. Hardware fitting and adjustment – hinges, lock gearbox, cylinder and handles fitted on a bench jig; the leaf is cycled 20 times and the strike adjusted until latch engagement is clean at 2.5-3.5 mm gasket compression.
  6. Packing – PE foam sleeve, corner protectors, 5-ply carton, then plywood crate for FCL or pallet for LCL.

Where Time Actually Goes

Operation Elapsed time Share of 30-day lead time Can be compressed?
Extrusion + ageing 2 days 7 % No – batch dependent
Coating 1 day 3 % No – oven cycle
CNC + assembly 4 days 13 % Yes, to 2 days at a rush premium
Core bonding press 1 day 3 % No – cure time
Glazing + hardware 2 days 7 % Partly
Shop drawing approval (buyer) 5-9 days 17-30 % Yes – the biggest single saving

Shop drawing approval is typically the longest line item in the schedule and the only one the buyer controls. Returning a marked drawing within 48 hours takes 4-7 days out of a standard 30-day lead time.

Quality Control: Inspection Points and Test Records

The line runs a 100 percent inspection rule on critical characteristics rather than AQL sampling. Each leaf carries a serial number that ties to a digital record.

Inspection Points on Every Door

Check Tolerance / limit Method Record
Frame squareness ≤ 1.5 mm over 2 m diagonal Digital square gauge Serial record
Leaf gap to frame 3.0 ± 0.5 mm Feeler gauge at 8 points Serial record
Gasket continuity No visible break, corners mitred and bonded Visual + 8-bar probe Serial record
Lock engagement Full throw on all points, handle torque ≤ 3 N·m 20-cycle bench test Serial record
Glass mark Tempered logo + standard + plant code present Visual Serial record
Coating thickness Within class (e.g. 60-120 μm) Eddy-current gauge, 5 points Batch record
Coating adhesion Class 0 cross-cut (EN ISO 2409) Cross-cut on a coupon Batch record
Wall thickness Nominal -0.05 mm Ultrasonic, 3 points per length Batch record

Type Test Records Held by the Factory

What a Buyer Should Ask For Before Shipment

Buyers consolidating entry doors with windows on the same container should also read the door and window accessory and soundproof specification so that hardware and gasket spares are ordered with the first shipment – a 2 percent spare parts allowance on hardware costs about $1.40 per door and removes most warranty call-outs.

Front Entry Door Price Tables: FOB Foshan in USD

Prices below are FOB China per square metre of door opening and per complete set, excluding freight, insurance and customs. They cover a pre-hung assembly: leaf, frame, threshold, multipoint lock, cylinder, three hinges, a lever handle and a pair of gaskets.

Per Square Metre by Configuration

Configuration Profile wall Thermal break Glazing Core FOB USD/m²
Standard 1.4 mm None 5 + 12A + 5 clear PU 40 $118 – 165
Standard plus 1.6 mm 14.8 mm PA66GF25 5 + 12A + 5 clear PU 45 $152 – 198
Mid 1.8 mm 24 mm PA66GF25 5 Low-E + 16Ar + 5 PU 45 $185 – 245
Mid wide 1.8 mm 30 mm PA66GF25 5 Low-E + 16Ar + 5 PU 55 $218 – 286
Premium 2.0 mm 34 mm PA66GF25 Triple Low-E, 2 x Ar PU 55 $285 – 395
Premium passive 2.0 mm 34 mm + foamed cavity Triple Low-E, 2 x Ar Rock wool 90 $340 – 452
Impact / HVHZ 2.0 mm 24 mm PA66GF25 6 Low-E lam + 12Ar + 6 lam PU 55 $420 – 580

Per Complete Set by Size and Tier

Nominal size Standard Mid Premium Impact Set weight (kg)
838 x 1,981 mm (UK) $218 – 302 $344 – 452 $520 – 690 $760 – 1,050 34 – 46
900 x 2,000 mm (EU) $232 – 320 $362 – 470 $548 – 720 $800 – 1,100 36 – 48
914 x 2,032 mm (US 36×80) $236 – 328 $368 – 478 $558 – 735 $815 – 1,120 37 – 50
914 x 2,438 mm (US 36×96) $286 – 396 $442 – 574 $668 – 878 $975 – 1,340 44 – 60
1,000 x 2,100 mm (EU tall) $268 – 370 $414 – 540 $626 – 824 $915 – 1,260 42 – 57
1,200 x 2,400 mm (dual leaf) $520 – 720 $812 – 1,056 $1,226 – 1,612 $1,790 – 2,460 78 – 106
Budgeting note: per-set pricing is more useful than per-square-metre pricing for entry doors, because hardware dominates. On a 914 x 2,032 mm mid-tier set at $420, the breakdown is roughly: frame and leaf $268, hardware $92, threshold and gaskets $34, crating $16, factory margin and overhead $10. A per-square-metre quote alone hides a $40 hardware downgrade that is invisible until the container arrives.

Option Adders

Option Adder Unit Lead time impact
Multipoint lock upgrade, 3 to 5 point $18 – 42 per set 0 days
3-star cylinder (EN 1303) $12 – 28 per set 0 days
Concealed hinge set $15 – 35 per set 2 days
Automatic drop-down bottom seal $9 – 18 per set 0 days
Thermally broken threshold $26 – 48 per set 2 days
Flush / low threshold (ADA / AS 1428.1) $34 – 62 per set 3 days
Warm-edge spacer $4 – 7 per set 0 days
PVDF coating (AAMA 2605) $11 – 18 per m² 2 days
Wood grain sublimation $12 – 20 per m² 5 days
Anodising AA20 $9 – 15 per m² 5 days
Sidelight panel $85 – 160 per panel 3 days
Transom panel $70 – 130 per panel 3 days
Smart lock with fingerprint $95 – 180 per set 6 days
Motorised multipoint $180 – 260 per set 8 days
Fire rating to EI30 $310 – 540 per set 12 days

Volume Breaks

Order quantity Discount on the per-m² rate Typical project
20 – 49 sets 0 % (list) Single house or small developer batch
50 – 149 sets 4 – 7 % Townhouse phase, small apartment block
150 – 399 sets 8 – 11 % Multi-phase residential development
400 – 999 sets 12 – 15 % Large development, repeat programme
1,000+ sets 16 – 20 % + shared tooling National builder programme

Volume discounts apply per model, not per order. A 300-set order spread over six models does not reach the 150-set break. Consolidating finishes and sizes to reach a break is usually worth more than the aesthetic loss: moving from four colours to one on a 200-set order saves 8 percent, about $6,700 on a mid-tier specification.

Landed Cost Model: Freight, Duty and Installed Cost per Set

FOB is not the decision number. The table below builds the landed cost for 200 mid-tier sets, 914 x 2,032 mm, shipped to Houston, Texas.

Worked Example: 200 Sets to the US Gulf Coast

Cost line Basis Amount (USD) Per set
FOB Foshan 200 sets at $420 $84,000 $420.00
Inland haulage to port Nansha to Yantian, containerised $420 $2.10
Documentation and handling Export clearance, B/L, certificate $580 $2.90
Ocean freight 3 x 40HQ, Foshan to Houston $8,100 $40.50
Marine insurance 0.18 % of CIF x 110 % $186 $0.93
US customs duty HTSUS 7610.10.00, verify the current rate $3,318 $16.59
Trade remedies Verify current Section 301 / 232 lists verify verify
Port, ISF and brokerage Entry, ISF, THC, delivery order $1,640 $8.20
Drayage to site Houston port to Katy, 60 km $1,200 $6.00
Landed subtotal Excluding trade remedies $99,444 $497.22
Installation labour 2 fitters, 1.2 h per set at $68/h $32,640 $163.20
Sealants, shims, anchors Consumables per set $2,200 $11.00
Installed cost Delivered and fitted $134,284 $671.42
Trade remedy warning: aluminium products entering the United States have been subject to Section 232 derivative duties, Section 301 tariff lists and several anti-dumping and countervailing duty investigations covering aluminium extrusions. The applicable rate changes by administrative action and depends on the classification of the finished door. Before quoting, confirm the HTSUS subheading with a broker and check the current Federal Register notices. In the European Union, definitive anti-dumping duties on aluminium extrusions from China apply under the TARIC database with exporter-specific rates; classification of a finished doorset under an extrusion code must be checked case by case. Treat any figure quoted without this check as incomplete.

Container Loading Arithmetic

A pre-hung 914 x 2,032 mm set packs at 2,140 x 1,050 x 190 mm, which is 0.427 m³ and about 47 kg with the crate share. A 40HQ gives 68 m³ of usable volume and 26,500 kg of payload.

Procurement Data: MOQ, Lead Time, Payment and Packaging

Commercial Terms

Term Standard position Negotiable to
MOQ 20 sets per model and colour 10 sets at a 6 % surcharge
Minimum order value $8,000 $5,000 for a first sample order
Lead time 25 – 35 days after deposit and drawing approval 18 days at a 9 % rush premium
Sample 1 set in 12 – 18 days at list plus air freight Credit against the first production order
Payment T/T 30 % deposit, 70 % against B/L copy L/C at sight; D/P at 30 days for repeat buyers
Currency USD EUR accepted, settled at the B/L date rate
Price validity 30 days from quotation 60 days with a volume commitment
Warranty 10 years on the frame and coating, 2 years on hardware 15 years on AAMA 2605 coating

Packaging Specification

Ordering Sequence

  1. Send the schedule: sizes, quantities, handing per unit, finish, glazing and hardware grade.
  2. Receive a budget quotation within 48 hours, valid 30 days.
  3. Confirm the shop drawing set, usually 5-9 days of iteration.
  4. Pay the deposit; production slots are allocated on deposit date, not on quotation date.
  5. Factory builds and photographs; a mid-production photograph set is sent at about day 18.
  6. Balance payment against the bill of lading copy; container released.
  7. Documents couriered: commercial invoice, packing list, certificate of origin, DoP where applicable, test certificates, ISPM-15 statement.

Installation Method: Nine Steps, Waterproofing and Commissioning

Most warranty claims on entry doors are installation failures, not product failures. The sequence below is the factory method and is printed on the crate label.

Nine-Step Installation Sequence

  1. Check the structural opening against the shop drawing. Shim gap should be 10-12 mm per side; reject any opening more than 25 mm out of square over 2 m.
  2. Fit a sill pan or a flexible flashing membrane across the base of the opening, turned up 100 mm at each jamb. This is the single step most often skipped and the cause of most sill leaks.
  3. Apply butyl tape to the outer face of the frame flange before the frame enters the opening.
  4. Set the frame on packers, plumb in both planes, and fix through the jamb at 600 mm centres with stainless anchors. Do not fix through the thermal break strip.
  5. Fit the leaf and adjust the hinges so the gap is even at 3.0 mm top and sides, and the leaf does not drop under its own weight when released at 45 degrees.
  6. Fit the strike and adjust until the latch engages at 2.5-3.5 mm of gasket compression; the handle should return without binding.
  7. Seal the exterior perimeter with neutral-cure silicone over a closed-cell backing rod. Acetic-cure silicone attacks the coating and voids the coating warranty.
  8. Fit the threshold end caps and check that the drainage slots are clear of mortar and of the sill pan membrane.
  9. Commission: cycle the leaf 20 times, verify all multipoint bolts throw fully, and run a hose test.

Hose Test Procedure

Run to AAMA 501.2 or EN 1027 practice: a 20 mm nozzle at 100 L/h per square metre of opening, held 300 mm from the face and swept at 0.5 m per 5 seconds for 5 minutes per face. Acceptance is no water penetration on the interior face beyond 50 mm from the frame. Test after the silicone has cured for 24 hours, not before, and re-test one elevation in every twenty.

Three Failure Points That Cause Most Call-Backs

Failure Symptom Root cause Prevention
Sill leak at the corner Water on the interior floor after wind-driven rain Sill pan membrane not turned up at the jamb, or cut by an anchor Pre-formed corner pans; anchor through the jamb, never the sill
Threshold condensation Water pooling on the inner threshold face in winter Non-broken threshold on a broken frame, or a foil-insulated trickle vent blocked Thermally broken threshold; keep weep holes clear
Leaf drop Leaf binds on the strike after 6-12 months Two hinges on a leaf above 2,100 mm, or fixing through the polyamide strip Three hinges above 2,100 mm; fix through the outer chamber only

Commissioning Checklist

Case Study: 72 Townhouse Units, Katy, Texas

A developer building 72 townhouse units in the Houston metropolitan area needed a single entry door specification covering two handing variants and three facade colours.

Specification and Constraints

Parameter Requirement Specified build Tested result
Size 36 x 80 in, two handing variants 914 x 2,032 mm, 41 left / 31 right As drawn
Wind ASCE 7-16, Vult 130 mph, Exposure B NAFS LC-PG40, ±1,900 Pa Passed at ±1,950 Pa
Water No penetration under ASTM E331 EN 12208 Class 7A equivalent, 300 Pa 300 Pa, no leak
Thermal IECC 2021 zone 2, U-factor ≤ 0.40 24 mm break, Low-E DG, warm edge NFRC U-factor 0.29
Security Builder standard, no PAS 24 5-point multipoint, Grade 1 cylinder Passed
Accessibility ADA 404.2.5 on 12 accessible units Bevelled threshold, 11 mm rise at 1:2 Passed
Finish 3 facade colours AAMA 2604, 7016 / 9016 / 8017 Film 92 – 106 μm
Programme Delivery over 3 phases 25 sets, 22 sets, 25 sets Delivered on phase dates

Cost Comparison

Cost line Local US supplier quote China factory, landed Difference
Door set, delivered to site $1,850 $497 – $1,353
Installation labour $163 $163 $0
Sealants and consumables $11 $11 $0
Spares at 2 % included $9 + $9
Warranty call-out provision $45 $38 – $7
Total per set $2,069 $718 – $1,351
Project total, 72 sets $148,968 $51,696 – $97,272

The saving is 65.3 percent on the delivered set and 65.3 percent on the installed total. The developer retained the local installer for fitting, which kept the labour line identical between the two options, and applied the saving to upgrading the window package on the same development.

Measured Outcome After 18 Months

Projects that need a wider opening or a paired configuration should review the aluminum sliding glass door configurations and U-values alongside this specification, because the entry door and the patio door on the same facade are usually finished in the same coating batch to avoid a colour mismatch.

Entry Door Material Comparison: Aluminum, Steel, Fiberglass, Timber, uPVC

Five materials compete for the residential entry door. The table below is measured on a 914 x 2,032 mm single leaf with a mid-tier glazing specification.

Ten-Parameter Comparison

Parameter Aluminum thermal break Insulated steel Fiberglass (GRP) Engineered timber uPVC
Ud (W/m²K) 1.55 – 1.70 1.10 – 1.35 1.00 – 1.25 1.20 – 1.50 1.30 – 1.60
Leaf weight (kg) 36 – 48 45 – 62 32 – 44 52 – 70 30 – 42
Dent resistance Moderate, skin thickness dependent High on 20-gauge and above High, can crack on impact Moderate, dents and recovers slowly Low, scratches show
Corrosion / rot Class 4-5 with the right coating Rusts if the skin is breached No corrosion Rot risk at the sill and bottom rail No corrosion, UV chalks
Thermal movement (mm over 2 m, 40 K swing) 4.6 2.7 2.2 1.4 7.2
Max leaf height without reinforcement 2,700 mm 2,400 mm 2,100 mm 2,400 mm 2,100 mm
Finish range Any RAL, PVDF, anodised, wood grain Factory paint, limited range Gel coat, stainable Stain or paint White, foiled, limited dark options
Recoat interval 15 – 25 years 8 – 12 years 10 – 15 years 3 – 5 years Not normally
FOB China price (USD/set) $344 – 452 $280 – 380 $410 – 560 $520 – 780 $190 – 280
Best application Modern facades, tall openings, coastal with 2605 Budget security doors, apartments Cold climates, timber look without maintenance Heritage and conservation areas Lowest budget, mild climates

Thermal Movement Is the Deciding Number

The coefficient of linear expansion for aluminum is 23 x 10⁻⁶ per Kelvin, for steel 12 x 10⁻⁶, for GRP 11-13 x 10⁻⁶, for timber 4-6 x 10⁻⁶ along the grain and for uPVC 70-80 x 10⁻⁶. On a 2,032 mm leaf with a 40 Kelvin seasonal swing, uPVC moves 5.7-6.5 mm and aluminum moves 1.9 mm. This is why uPVC doors bind in summer and rattle in winter, and why the aluminum door hinge and strike tolerances in this article (3.0 mm gap, 2.5-3.5 mm gasket compression) are much tighter than the equivalent uPVC figures.

Whole-Life Cost Over 25 Years

Material Initial (USD/set) Maintenance over 25 y Replacement in period 25-year cost
Aluminum, AAMA 2604 $420 $180 (2 recoats of touch-up, hardware service) 0 $600
Aluminum, AAMA 2605 $436 $90 (hardware service only) 0 $526
Insulated steel $330 $420 (repainting at 10 y and 20 y, rust repair) 0 $750
Fiberglass $480 $140 (gel-coat refresh, hardware) 0 $620
Engineered timber $650 $1,100 (restaining every 4 y, sill repair at 15 y) 0 $1,750
uPVC $235 $260 (hardware, seal replacement at 12 y) 1 at year 18 ($290) $785

The numbers assume a temperate climate without a coastal salt load. Within 5 km of a coastline, add $120-260 to the steel and uPVC maintenance lines and $0 to a correctly specified AAMA 2605 aluminum build.

Selection by Project Type and Climate

Six Project Profiles

Project type Recommended tier Break width Glazing Threshold Budget (USD/set)
Single dwelling, mild climate Standard plus 14.8 mm 5 + 12A + 5 clear Exposed 19 mm $152 – 198
Single dwelling, cold climate Mid wide 30 mm 5 Low-E + 16Ar + 5 Broken, 14 mm $252 – 334
Townhouse development Mid 24 mm 5 Low-E + 16Ar + 5 Broken, bevelled 11 mm $368 – 478
Apartment entry, fire rated Premium, EI30 24 mm EI30 fire glass Broken, flush 5 mm $870 – 1,260
Coastal / HVHZ Impact 24 mm Laminated, TAS 201 Rebated 15 mm $815 – 1,340
Passive house / EU new build Premium passive 34 mm, foamed Triple Low-E, 2 x Ar Broken, flush 0 mm $626 – 824 + threshold

Climate Rules of Thumb

When Not to Use Aluminum

Aluminum is the wrong choice in three situations. First, where a conservation authority requires a solid timber section and a painted finish – the anodised or powder look reads as metal at close range. Second, where the budget is under $200 per set and the climate is mild, in which case uPVC is cheaper and adequate. Third, where the door must be cut or trimmed on site to fit an irregular opening – aluminum cannot be planed or sawn in place, and the door must be made to the measured size. In all three cases one of the other four materials in the comparison table is the correct answer, and a buyer should say so rather than force the specification.

RFQ Checklist: What to Send for an Accurate Quotation

Eight Technical Items

  1. Schedule of sizes with quantities, and the handing of each unit shown on a plan symbol.
  2. Facade condition: masonry, blockwork, timber stud or steel stud, with the reveal depth.
  3. Wind and water requirement: design pressure in Pa or psf, and the standard (EN 12210, NAFS class and PG, AS 2047 N rating).
  4. Thermal requirement: target Ud or U-factor, and the calculation standard (EN ISO 10077-1 or NFRC 100).
  5. Glazing specification: build-up, Low-E type, spacer, tint, obscuration and any safety class.
  6. Hardware grade: ANSI/BHMA grade or EN grade for lock, cylinder, hinge and closer; plus whether PAS 24 or RC2 certification is required.
  7. Finish: AAMA class or Qualicoat class, RAL or anodised reference, and whether internal and external differ.
  8. Threshold type and any accessibility requirement: ADA 404.2.5, AS 1428.1, or Part M.

Eight Commercial Items

  1. Incoterm: FOB, CIF or DDP, and the named port.
  2. Destination country and, for the United States, the state – because the HVHZ counties in Florida carry a different requirement.
  3. Quantity per model, per colour and per finish, since volume breaks apply per model.
  4. Required delivery date and whether phased deliveries are needed.
  5. Payment preference: T/T, L/C at sight, or an open account arrangement for repeat buyers.
  6. Whether a sample set is required before production, and whether the sample cost is to be credited.
  7. Whether third-party inspection is required, and by whom.
  8. Spare parts allowance: the standard recommendation is 2 percent of hardware and 1 percent of gasket length.
A quotation request that omits the handing plan symbol and the design pressure will come back as a budget estimate with a ± 18 percent band. A complete request returns a firm price within 48 hours with a ± 4 percent band, and the shop drawing can start immediately.

Glossary of Front Entry Door Terms

Product and Component Terms

Term Definition
Leaf The moving panel of a door, hung on hinges within a frame.
Pre-hung A door supplied as a leaf already hung in its frame with hardware fitted.
Stile The vertical edge member of a leaf; the lock stile carries the lock, the hinge stile the hinges.
Rail The horizontal member of a leaf, at the top, bottom or mid-height.
Sidelight A fixed glazed panel installed beside a door leaf.
Transom A fixed glazed panel installed above a door leaf.
Threshold The bottom member of the frame that closes the floor junction.
Multipoint lock A lock engaging the frame at three or more points from one handle throw.
Shootbolt A bolt that extends vertically into the head or sill.
Mushroom cam A mushroom-shaped locking cam that resists the leaf being spread from the frame.
Thermal break The polyamide strip separating inner and outer aluminium halves of a profile.
Warm-edge spacer A low-conductivity spacer in an insulating glass unit that cuts edge heat loss.

Standard and Compliance Terms

Term Definition
Ud Whole-door thermal transmittance, W/m²K, to EN ISO 10077-1.
U-factor North American equivalent of Ud, Btu/h·ft²·°F, to NFRC 100.
fRsi Temperature factor, used to assess condensation risk; higher is better.
DP (design pressure) The pressure a door is rated to resist, in psf (NAFS) or Pa (EN).
RC class Burglar resistance class to EN 1627, RC1N to RC6.
PAS 24 UK enhanced security test specification for doorsets, referenced by Approved Document Q.
HVHZ High Velocity Hurricane Zone, the Florida counties requiring Miami-Dade NOA or Florida Product Approval.
NAFS North American Fenestration Standard, AAMA/WDMA/CSA 101/I.S.2/A440.
DoP Declaration of Performance, the CE document listing declared characteristics.
AVCP Assessment and Verification of Constancy of Performance, the CE conformity route (system 1-4).
EI30 / EI60 Fire resistance classification: integrity and insulation for 30 or 60 minutes.
IPSM-15 The phytosanitary standard requiring heat treatment or fumigation of wood packaging.

Entry doors are normally ordered together with the rest of the exterior package. The links below carry the same coating batch and the same hardware platform, which avoids a colour or finish mismatch across a facade.

Entry and Exterior Door Series

Window and Full-Range Packages

[footer_contact_form]