Prefab House Export from China: Sandwich Panel U-Values and FOB Pricing

Prefab house in China with insulated sandwich panel cladding and aluminium thermal break windows - modular residential building exterior
Two-module prefab house with insulated sandwich panel cladding and thermal break aluminium windows.
Prefab house refers to a dwelling whose structure and envelope are manufactured in a factory as cassettes or volumetric modules and assembled on a prepared foundation. The engineering questions that decide the delivered cost are transport geometry, envelope U-value, joint thermal bridging and the window specification. This article documents all four with calculated numbers: sandwich panel U-values per EN 14509, whole-window U-values per EN ISO 10077-1, a 120 m2 reference house heat-load calculation, container loading arithmetic, USD price tables, production parameters, certification paths, procurement terms, the erection sequence and delivered project data for prefab houses sourced from China. Structural checks use E = 210,000 MPa for S350 GD+Z light steel and 69,000 MPa for 6063-T5 aluminium.
Wall U (100 PIR)
0.212 W/m2K
Window Uw
0.72 W/m2K
House FOB
$320-780/m2
Heat load
22.7 W/m2
MOQ
2 units
Lead time
35-45 days
Contents
1. Structural Systems and Module Grid
2. Prefabricated House Envelope
3. Container Houses and Cut-Outs
4. Sandwich Panels Compared
5. Passive House Windows and Uw
6. Price Table (USD)
7. Production Process
8. Technical Indicators
9. Certifications
10. Procurement Data
11. Installation Method
12. Project Data
13. Configuration Comparison
14. Related Systems

Prefab House Structural Systems – Module Grid, Frame and Lifting Loads

A prefab house is dimensioned by the transport envelope before it is dimensioned by the floor plan. Decide the shipping mode first, because a module 100 mm too tall changes the freight cost by a factor of three.

Module Grid and the ISO Transport Envelope

Three shipping modes are available. Volumetric modules ship complete on a flat rack or as breakbulk. Flat-pack cassette sets ship inside standard containers. Container-derived units reuse ISO corner castings. The controlling dimensions are the 40HQ internal height of 2.69 m and the door opening of 2.34 m width.

Mode Unit size (m) Payload per 40HQ Freight $/m2 floor Typical use
Volumetric module 6.06 x 2.44 x 2.90 1-2 units on flat rack 150-320 Resort, remote site
Flat-pack cassette 6.0 x 3.0 x 0.35 2-3 units (36-54 m2) 41-125 Standard housing
ISO container unit 6.06 x 2.44 x 2.59 2 units, 30 m2 105-210 Site camp, pop-up

The ISO 20 ft module at 2.896 m overall height does not pass a 40HQ door at 2.69 m internal height. This single dimension is the reason most volumetric exporters quote flat rack rates. Flat-pack is the default for a cost-driven project.

Weight, not volume, sets the container count. A 6.0 x 3.0 m module packs to 19.9 m3 (floor cassette 6.30 + roof cassette 6.30 + wall panels 7.29), so a 76 m3 40HQ fits 3.8 modules by volume. At 8 t per module the 26 t payload caps it at 3 units = 54 m2. At 9-11 t it drops to 2 units = 36 m2. Specify the cassette weight before you price the freight.

Light-Steel Floor Joist Check – C200 x 70 x 20

Floor cassettes use S350 GD+Z lipped C-sections at 600 mm centres. For a 3.0 m span carrying EN 1991-1-1 Category A residential loading the check is as follows. Characteristic loads: live 2.0 kN/m2, finishes 0.5 kN/m2, self weight 0.15 kN/m2. At 600 mm centres the line load on one joist is 1.59 kN/m, giving M = wL2/8 = 1.789 kN.m.

Wall I (mm4) W (mm3) sigma (MPa) delta (mm) Span ratio Verdict
2.0 mm 4.077e6 40,770 43.9 1.96 L/1532 Pass
1.5 mm 3.069e6 30,690 58.3 2.60 L/1153 Pass
1.2 mm 2.451e6 24,510 73.0 3.26 L/921 Pass

Allowable stress is 205 MPa and the EN 1993-1-1 deflection limit for floors is L/250 = 12 mm. All three walls pass with a factor of 2.8 to 4.7 on stress and 4 to 12 on deflection. Bending is therefore not the governing case for a prefab house floor cassette.

Four-Point Lifting and Corner Casting Loads

The governing load case is the crane lift, not occupancy. A 12 t module weighs 117.7 kN. With a four-point lift and slings at 60 degrees to horizontal, each sling carries 29.4 kN vertical and the sling tension is T = 29.4 / sin 60 = 34.0 kN. The horizontal component pulled into each top corner is 29.4 / tan 60 = 17.0 kN.

Specify the lifting scheme in the contract. A factory can build a cassette that passes every occupancy check and still fails on the first crane lift if the top rail is not continuous.

Prefabricated House Envelope – Cassettes, Air Barrier and Joint Schedule

A prefabricated house only performs to its calculated U-value if the air barrier is continuous across every cassette joint. The insulation thickness matters less than the joint detailing.

Wall, Roof and Floor Cassette Build-Ups

Three cassette types make up the envelope. Each is a closed panel with a structural frame, insulation and both facing layers fitted in the factory, so the site operation is a mechanical fix and a seal, not a wet trade sequence.

Cassette Frame Insulation Facings Thickness Weight kg/m2 U W/m2K
Wall C140x50x1.5 @600 140 mm rock wool 0.5 steel + 12.5 board 180 mm 38 0.255
Roof C200x70x2.0 @600 200 mm PIR + 40 mm 0.6 steel + 15 mm OSB 280 mm 46 0.120
Floor C200x70x2.0 @600 200 mm PIR 18 mm cement board both sides 260 mm 52 0.108
Party wall C140x50x1.5 @600 2 x 60 mm rock wool 2 x 15 mm board 200 mm 54 0.193

The roof cassette carries the highest insulation load because it is also the stiffest diaphragm. Floor cassettes use cement board rather than OSB in wet rooms; specify this explicitly because the substitution costs 4-6 USD/m2 and is rarely offered by default.

Air Tightness – n50 Targets and Blower-Door Arithmetic

Measured air permeability is reported as n50 in air changes per hour at 50 Pa. For the 120 m2 reference house with V = 324 m3 and a total envelope area of 410 m2, the conversion between n50, the leakage flow and the area-normalised q50 is:

n50 (1/h) Q50 (m3/h) q50 m3/(h.m2) Average ACH (n50/20) Infiltration W/K
0.6 194 0.47 0.030 3.2
1.0 324 0.79 0.050 5.3
2.0 648 1.58 0.100 10.7
3.0 972 2.37 0.150 16.0
5.0 1620 3.95 0.250 26.7

The Passive House Institute limit is n50 of 0.6 h-1. Most national building codes accept q50 of 5.0 m3/(h.m2). Factory-built envelopes reach n50 of 0.6 to 1.5 routinely because the joints are made on a bench rather than on scaffolding. Going from n50 5.0 to n50 1.0 removes 21.4 W/K of infiltration loss, which at a 2,700 K.d heating season is 1,387 kWh/a.

Write the n50 number into the contract as a testable value. Specify a blower-door test to EN ISO 9972 at handover with a measured n50 not exceeding 1.0 h-1, and hold 5 percent of the contract value against it. Without a test clause the number is marketing, not a specification.

Cam-Lock Joint Thermal Bridge

Cassette joints use cam-lock fasteners that pull both steel facings into contact. Where the two 0.5 mm steel faces touch, the insulation is bypassed by a highly conductive path. The linear thermal transmittance of that joint is the psi value, and over 100 m of joint line it is significant.

Joint detail psi (W/mK) Loss over 100 m (W/K) Share of house UA
Steel-to-steel cam-lock 0.15 15.0 13.8%
Standard sealed spline 0.10 10.0 9.2%
Insulated cam-lock + pad 0.05 5.0 4.6%
Thermal isolator spline 0.03 3.0 2.8%

Against a reference total of 108.6 W/K, an unbroken steel cam-lock joint adds 13.8 percent to the whole house heat loss. The fix is a 6 mm aerogel or rigid PU isolator pad at each cam-lock, which costs 0.8-1.5 USD per fastener and returns 10 W/K.

Container Houses – Cut-Out Reinforcement and Window Integration

Container houses reuse an ISO freight container as the primary structure. The corrugated side panel is a stressed skin, so every opening is a structural intervention and must be framed.

Side-Wall Shear Loss and Header Sizing

A 20 ft container side wall is 12.192 x 2.591 m = 31.59 m2. A 2400 x 1200 mm window opening removes 2.88 m2, which is 9.1 percent of the diaphragm. The 1.6 mm SPA-H corrugated panel (yield 345 MPa) provides shear stiffness for racking; the corner posts carry the vertical load. Removing panel area therefore reduces racking resistance, not gravity capacity. The header over the opening must be sized for the load above it.

For a 2.4 m header carrying one roof plus one stacked unit at an upper-bound line load of 2.0 kN/m, the mid-span moment is M = wL2/8 = 1.44 kN.m and the required section modulus at 215 MPa allowable is 6,698 mm3.

Header section Ix (mm4) Wx (mm3) sigma (MPa) Utilisation
RHS 100 x 50 x 3.0 1.121e6 22,424 64.2 30%
RHS 120 x 60 x 4.0 2.552e6 42,533 33.9 16%
RHS 150 x 100 x 4.0 6.173e6 82,308 17.5 8%

RHS 100 x 50 x 3.0 is sufficient at 30 percent utilisation, so the constraint is not stress but the weld detail: the header must be continuously welded to the surviving corrugation on both faces, and the vertical jamb members must run full height to the bottom rail to restore the load path.

Window and Door Cut-Out Detailing

Container steel is Corten SPA-H, which is cathodic to aluminium. Direct contact drives galvanic corrosion of the window frame. The 10 mm reveal plus a nylon or EPDM isolator shim is not optional detail, it is the difference between a 5-year and a 25-year window life.

Corrosion and Coating Specification

Element Preparation System DFT (micron) Life to first maintenance
Container shell Sa 2.5 blast Zn-rich epoxy + PU topcoat 240 15-20 yr
Cut edges Grind St 3 Zn-rich primer + 2 PU coats 200 10-15 yr
RHS frame Mill scale removal Epoxy zinc phosphate 120 15 yr
Aluminium frame Chrome-free pre-treat Powder coat Qualicoat Class 1 60-80 25 yr
Aluminium frame (coastal) Chrome-free pre-treat PVDF 70 percent 40-50 30 yr

Sandwich Panels – EPS, PU/PIR and Rock Wool Compared

Sandwich panels are the standard prefab house cladding and the single largest lever on envelope U-value per dollar spent. The choice between core materials is a fire and acoustics decision as much as a thermal one.

U-Value by Core and Thickness – EN 14509 / ISO 6946

Values below are calculated as U = 1 / (Rsi + d/lambda + Rse) with Rsi = 0.13 and Rse = 0.04 m2K/W, insulation core only, facings ignored. EN 14509 additionally requires a joint factor for cam-lock panels.

Core (lambda W/mK) 50 mm 75 mm 100 mm 150 mm 200 mm
EPS (0.038) 0.673 0.466 0.357 0.243 0.184
PU / PIR (0.022) 0.409 0.279 0.212 0.143 0.108
Rock wool (0.040) 0.704 0.489 0.375 0.255 0.193

PU/PIR reaches U 0.212 at 100 mm where EPS needs 175 mm and rock wool needs 185 mm. The practical consequence is floor area: at a 120 m2 house with 140 m2 of wall, moving from 100 mm EPS to 100 mm PIR reduces the wall heat loss from 50.0 W/K to 29.7 W/K and adds roughly 1.1 m2 of internal floor area on a 6 x 3 m module because the wall is 75 mm thinner.

Reaction to Fire and Fire Resistance

Core Reaction to fire (EN 13501-1) Fire resistance 100 mm Smoke Habitable approval
EPS E (B-s1,d0 with FR additive) None – melts at 100 C s2-s3 Rarely accepted
PU B-s2,d0 EI 20-30 min s2 Conditional
PIR B-s1,d0 EI 30-45 min s1 Commonly accepted
Rock wool A2-s1,d0 EI 60-120 min s1 Accepted all uses

Rock wool is the only core that is non-combustible. For a habitable two-storey prefab house, and for any unit within 1 m of a boundary, specify A2-s1,d0. The cost premium over PIR is 4-7 USD/m2 of panel, and the U-value penalty at equal thickness is offset by moving from 100 mm to 150 mm.

Wind Uplift, Snow and the Fastener Schedule

Roof panels must resist net uplift. Velocity pressure is q = 0.613 v2; with an external pressure coefficient of -1.2 in the corner zone and an internal coefficient of +0.2, the net factor is 1.4.

Gust speed q (kPa) Net uplift (kPa) Fastener load @300×600 (N) Note
30 m/s 0.55 0.77 139 Inland temperate
35 m/s 0.75 1.05 189 Exposed inland
40 m/s 0.98 1.37 247 Coastal / typhoon
45 m/s 1.24 1.74 313 Miami-Dade HVHZ
50 m/s 1.53 2.15 387 Cyclone region

Panel self weight for a 100 mm PIR roof with 0.5/0.5 mm steel facings is about 0.14 kPa, so at 1.37 kPa net uplift the panel is being pulled off with roughly ten times its own weight. Anchorage is not optional. A self-tapping screw into 2.0 mm steel has a pull-out capacity of 1.5-2.5 kN against a demand of 247 N, so the fastener is not the weak link – the steel purlin flange thickness is. Specify 2.0 mm minimum purlins and do not let the value engineering stop at 1.5 mm.

Panel thickness 60 mm 80 mm 100 mm 120 mm 150 mm
Max roof span (1.25 kPa) 1.8 m 2.4 m 3.0 m 3.5 m 4.2 m
Max wall span (1.0 kPa) 2.6 m 3.4 m 4.2 m 5.0 m 6.0 m

Acoustic Performance and Flanking

Sandwich panels are mass-spring systems. Two 0.5 mm steel facings (3.9 kg/m2 each) separated by a low dynamic stiffness core produce a resonance typically between 60 and 100 Hz. Below that frequency the sound reduction falls away sharply, which is why lightweight prefab envelopes transmit road and aircraft rumble that the Rw number does not predict.

Build-up Rw (dB) tau Indoor level at 70 dB(A) road Comment
100 mm PIR panel 25 3.16e-3 45 dB(A) Above WHO 40 dB night limit
100 mm rock wool panel 30 1.00e-3 40 dB(A) At the limit
150 mm rock wool panel 32 6.31e-4 38 dB(A) Acceptable
Panel + decoupled inner leaf 48-52 – 18-22 dB(A) Flanking limited

A decoupled inner leaf of two 12.5 mm plasterboard layers on a 50 mm stud with 50 mm wool raises the composite from 25 dB to 48-52 dB. In practice the achieved value is capped by flanking at the floor and ceiling junctions, so the resilient detail must continue across those junctions or the measured result will land near 42 dB.

Passive House Windows – Uw Arithmetic, Glazing and psi-Install

Passive house windows are the component that decides whether a prefab envelope meets its energy target. On the 120 m2 reference house, glazing is 7.3 percent of the envelope area but was 57 percent of the heat loss before the window was upgraded.

Whole-Window U-Value – EN ISO 10077-1

Uw is an area-weighted sum of frame, glazing and the spacer edge effect: Uw = (Af x Uf + Ag x Ug + lg x psig) / (Af + Ag). For a 1500 x 1500 mm window the reference geometry is Af = 0.63 m2, Ag = 1.62 m2, lg = 5.08 m, total 2.25 m2.

Build-up Uf Ug psi_g Uw (W/m2K)
Aluminium, no break, 6-12-6 air, alu spacer 5.90 2.80 0.080 3.849
14 mm PA66, 5-12A-5 Low-E, alu spacer 3.00 1.40 0.060 1.983
24 mm PA66, 5-12Ar-5 Low-E, alu spacer 2.20 1.10 0.050 1.521
34 mm PA66 + foam, 5-12Ar-5 Low-E, warm edge 1.50 1.10 0.040 1.302
44 mm foam break, 4-12-4-12-4 argon, warm edge 0.80 0.60 0.030 0.724
44 mm foam break, 4-14-4-14-4 krypton, warm edge 0.75 0.44 0.030 0.595

The Passive House Institute certified component limit is Uw of 0.80 W/m2K for a cool-temperate climate. Only the last two rows reach it. The single biggest step is not the glass: moving from no break to a 24 mm PA66 strip cuts Uw from 3.849 to 1.521, a 60 percent reduction driven entirely by the frame. Going from argon triple to krypton triple only moves Uw from 0.724 to 0.595.

Glazing Options – Argon, Krypton and Warm-Edge Spacers

Argon fills at 90 percent purity give Ug 0.60 in a 4-12-4-12-4 build. Krypton allows a narrower cavity and reaches Ug 0.44, but krypton costs roughly 8-12 USD/m2 more and the fill retention over 20 years is less well documented. A warm-edge spacer moves psi_g from 0.080 to 0.030, worth about 0.10-0.13 W/m2K on Uw – the cheapest single upgrade in the whole window.

Purchase order sequence. Spend in this order: (1) thermal break width, (2) warm-edge spacer, (3) Low-E coating, (4) triple glazing, (5) krypton fill. Buyers who order the krypton triple before the 34 mm break are paying for glass that the frame will waste.

Installation Thermal Bridge and psi-Install

Uw describes the window in the laboratory. The installed performance adds psi_install, the linear transmittance of the junction between the window and the wall. In a panel wall the window should sit in the insulation plane, strapped to the cassette frame, with the outer insulation overlapping the frame by 20-30 mm.

Installation position psi_install (W/mK) Effect on 30 m2 glazing Verdict
Frame flush with outer face 0.10 +15.0 W/K Fail
Frame at mid-insulation 0.05 +7.5 W/K Marginal
Frame in insulation plane + 25 mm overlap 0.02 +3.0 W/K Pass
PHI certified installation detail 0.01 +1.5 W/K Pass

At 0.10 W/mK over 30 windows with 5 m of perimeter each, the installation bridge alone is 15 W/K, comparable to the entire window transmission loss at Uw 0.72. The detail is specified on the shop drawing, not on site.

Condensation Check – EN ISO 13788

Internal surface temperature is theta_si = Ti – (Rsi / Rtot) x (Ti – Te). With Ti = 20 C and Te = -5 C, the dew point at 20 C is 9.3 C at 50 percent RH, 12.0 C at 60 percent, 13.2 C at 65 percent, 14.4 C at 70 percent and 16.4 C at 80 percent.

Local resistance (m2K/W) theta_si (C) Safe to indoor RH Condition
0.30 9.2 50% Condensation above 50 percent RH
0.40 11.9 58% Marginal
0.50 13.5 65% Acceptable for housing
0.65 15.0 72% Good
0.80 15.9 78% Passive house range

A through-metal panel joint with a local resistance of 0.50 gives theta_si = 13.5 C, which survives normal residential humidity but fails in a bathroom or kitchen at 70 percent RH. The fix is the same isolator pad that solves the psi problem, plus mechanical extract at 30 m3/h in wet rooms.

Price Table (USD) – Envelope, Windows and Complete Packages

All prices are FOB Shenzhen or Foshan, valid for a minimum order of two 6.0 x 3.0 m modules, excluding windows unless stated. Ranges reflect 2025 aluminium ingot and steel coil pricing.

Envelope and Window FOB Price Bands

Item Specification Unit USD Low USD High Note
Wall cassette 140 mm rock wool, 180 mm m2 58 96 Excludes linings
Roof cassette 200 mm PIR, structural m2 72 128 Includes OSB deck
Floor cassette 200 mm PIR, cement board m2 68 115 Wet-room grade +8
Sandwich panel 100 mm PIR, 0.5/0.5 m2 19 34 Cladding only
Sandwich panel 100 mm rock wool A2 m2 26 44 Non-combustible
Window, double 24 mm break, 5-12Ar-5 m2 95 165 Uw 1.52
Window, triple 44 mm foam, argon triple m2 185 310 Uw 0.72
Window, PH grade Krypton triple, warm edge m2 260 420 Uw 0.60
Sliding door 2-panel, 2400 x 2400 set 420 880 Hardware class dependent
Entry door Aluminium, thermal break set 280 640 With multipoint lock
Light steel frame S350 GD+Z, cut to length t 980 1,450 Z275 coating

Complete House Package Pricing

Package Envelope spec Windows USD/m2 floor 120 m2 house (USD)
Shell only 100 mm EPS panels Not included 120-190 14,400-22,800
Standard 100 mm PIR + board lining Uw 1.52 double 320-480 38,400-57,600
Enhanced 150 mm PIR, A2 lining Uw 1.30 warm edge 450-620 54,000-74,400
Passive 200 mm PIR, isolator joints Uw 0.72 triple 620-780 74,400-93,600
Passive + 250 mm, krypton glazing Uw 0.60 PH grade 740-960 88,800-115,200

The jump from Standard to Passive is 300 USD/m2 of floor area, of which 55-75 USD/m2 is the glazing upgrade and the remainder is insulation thickness and joint detailing. On 30 m2 of glazing the triple upgrade costs 30 x (185-95) = 2,700 USD at the low end.

Budget guidance. Freight, foundation and site works are not in these numbers. At 41-125 USD/m2 of freight, 90-180 USD/m2 for a piled or slab foundation and 150-320 USD/m2 for erection and finishing, add 280-625 USD/m2 to any FOB figure to reach a realistic delivered cost.

What Moves the Price

Production Process – From Coil to Loaded Container

Roll Forming, Panel Lamination and Cutting

Aluminium Extrusion, Thermal Break and Coating

Assembly, Pre-Installation and QC Gates

Gate Check Method Tolerance Record
G1 Incoming Coil certificate, coating mass Mill cert + weigh Z275 min Batch file
G2 Profile Wall thickness, temper Micrometer + hardness +/- 0.05 mm Extrusion log
G3 Break Shear bond of PA66 EN 14024 pull test > 24 N/mm Weekly coupon
G4 Panel Core density, bond Weigh + drum peel 38-42 kg/m3 Panel map
G5 Cassette Squareness, cam-lock torque Diagonal + torque gun 1.0 mm Unit card
G6 Glazing IGU seal, gas fill Spark test + gas analyser > 90% Ar IGU serial
G7 Pre-fit Dry assembly of one unit Full trial build Zero rework Photo pack
G8 Load Container plan, lashing Weighbridge + photos +/- 2% Loading report

Gate G7 is the one that saves money. A complete dry trial assembly of the first unit before the run starts costs 400-900 USD and typically finds three to six interference problems that would otherwise be solved with a grinder on site.

Technical Indicators – Envelope, Window and Whole-House Data

Envelope and Structural Data Sheet

Parameter Standard value Enhanced value Test standard
Wall U-value 0.212 W/m2K 0.108 W/m2K EN 14509
Roof U-value 0.160 W/m2K 0.090 W/m2K EN 14509
Floor U-value 0.220 W/m2K 0.110 W/m2K ISO 6946
Air tightness n50 1.0 h-1 0.6 h-1 EN ISO 9972
Joint psi 0.10 W/mK 0.03 W/mK EN ISO 10211
Floor live load 2.0 kN/m2 3.0 kN/m2 EN 1991-1-1
Wind load 1.0 kPa 2.15 kPa EN 1991-1-4
Snow load 1.0 kN/m2 2.5 kN/m2 EN 1991-1-3
Seismic 0.2 g 0.4 g EN 1998-1
Frame steel S350 GD+Z Z275 S390 GD+Z Z350 EN 10346
Bending span 3.0 m 4.2 m EN 1993-1-3

Window Performance Classes

Property Class / value Test standard Export market requirement
Air permeability Class 4 (600 Pa) EN 12207 EU, AU, ME
Water tightness E900 (900 Pa) EN 12208 EU, typhoon zones
Wind resistance C5 / 2000 Pa EN 12210 EU high rise
Wind resistance (US) DP 50 / 2400 Pa AAMA/WDMA 101/I.S.2 North America
Impact (HVHZ) Large missile, TAS 201/203 Miami-Dade NOA Florida, Gulf coast
Thermal (AU) Uw 1.30-0.72 AS 2047 / WERS Australia
Thermal (US) U 0.28-0.18 Btu/h.ft2.F NFRC 100 North America
Acoustic Rw 32-42 dB EN ISO 717-1 Urban, airport

Whole-House Heat Load – 120 m2 Reference

Reference house: 120 m2 floor, V = 324 m3, envelope 410 m2 of which 30 m2 is glazing (7.3 percent). Ventilation is 0.4 ACH mechanical with 85 percent recovery (6.4 W/K) plus infiltration at n50 1.0 (5.3 W/K), total air term 11.8 W/K. Heating season 2,700 K.d = 64.8 kKh.

Envelope spec UA opaque UA window UA total Season kWh/a Design load W/m2
Basic, Uw 3.85 226.2 115.5 353.5 22,904 54.1
Basic, Uw 0.72 226.2 21.7 259.7 16,829 54.1
Mid, Uw 3.85 75.3 115.5 202.5 13,123 22.7
Mid, Uw 0.72 75.3 21.7 108.8 7,048 22.7
High, Uw 0.72 52.4 21.7 85.9 5,566 17.9
Max, Uw 0.72 39.1 21.7 72.6 4,705 15.1

Two results matter. First, at the Mid envelope the windows are 7.3 percent of the area but 57.0 percent of the heat loss at Uw 3.85, falling to 20.0 percent at Uw 0.72 – the window is the dominant term in a well-insulated envelope. Second, the design heat load at delta T = 25 K falls from 54.1 to 22.7 W/m2 between the Basic and Mid envelopes, which halves the heat pump capacity from roughly 6.5 kW to 2.7 kW.

The 10 W/m2 Passive House limit is not reached by these envelopes. Even the Max specification gives 15.1 W/m2. At 25 percent glazing with Uw 0.72 the windows alone contribute 21.7 of 72.6 W/K. Reaching 10 W/m2 needs a more compact form, a warmer climate, or glazing at Ug 0.4 with a 300 mm envelope. State this before a client budgets for certification.

Certifications and Test Reports

CE, EN 1090 and EN 14509

NFRC, AAMA, Miami-Dade NOA and AS 2047

Certificate Scope Lead time Cost (USD) Validity
NFRC 100/200 U-factor, SHGC simulation 6-10 weeks 1,800-3,400 Per product line
AAMA/WDMA 101 DP rating, air, water 10-16 weeks 9,000-18,000 4 yr + audit
Miami-Dade NOA TAS 201/202/203 impact 20-32 weeks 26,000-48,000 1 yr + audit
AS 2047 (AU) Wind, water, infiltration 8-14 weeks 4,500-9,000 3 yr
PHI component Uw 0.80 or better 12-20 weeks 3,200-6,500 Per geometry
CE / DoP EN 14351-1 4-8 weeks Included Ongoing

Certification cost is per product line, not per order, so it belongs in the first unit price. A Miami-Dade NOA at 26,000-48,000 USD cannot be amortised over a two-module order; either the client commits to volume or the project specifies a different impact route.

Passive House Institute Component Database

A window with Uw of 0.80 W/m2K or better for a cool-temperate climate can be listed in the PHI component database. Listing requires a certified calculation to EN ISO 10077-1 including the frame cavity, the spacer and the installation detail, plus a PHPP-compatible data set. The 44 mm foam break with argon triple at Uw 0.724 qualifies; the 34 mm build at 1.302 does not.

Procurement Data – MOQ, Lead Time, Payment and Packing

MOQ and Order Structure

Item MOQ Reason Below MOQ surcharge
Prefab house module 2 units Roll-form setup 12-18%
Cassette set only 6 units Jig amortisation 10-15%
Sandwich panels 300 m2 Continuous line run 8-12%
Windows and doors 50 m2 / 20 units Extrusion batch 15-25%
PH grade glazing 30 m2 Krypton fill batch 20-30%

Lead Time and Production Slots

Stage Days Cumulative Note
Drawings and sign-off 7-12 12 Client approval gate
Material procurement 5-10 22 Coil and billet lead
Roll forming and lamination 8-14 36 Runs in parallel
Window fabrication 12-18 36 Parallel line
Dry trial assembly 2-3 39 Gate G7
Disassembly and packing 3-5 44 Container planning
Inland haul and loading 2-4 48 To port

A quoted 35-45 day lead time is achievable only when drawing sign-off happens in the first week. In practice the drawing gate absorbs 2-4 weeks of client-side revision; the factory portion is rarely the critical path.

Payment Terms and Incoterms

Packing, Container Loading and Freight

Item Packing 40HQ load Weight per unit Freight USD/m2
Floor cassette Steel stillage, strapped 3 units 2.6 t 41-125
Roof cassette Steel stillage, strapped 3 units 2.1 t –
Wall panel pack Timber crate, 15 per crate 4 crates 2.3 t –
Windows Foam + carton + crate 380 m2 1.4 t/100 m2 6-14
Hardware kit Boxed, one per unit 12 boxes 0.3 t –

Freight per square metre of floor area ranges from 41 USD at three 8 t modules on a 2,200 USD lane to 125 USD at two modules on a 4,500 USD lane. Because the payload limit binds before the volume limit, every kilogram removed from the cassette specification converts directly into freight. A 1.1 t reduction per module is worth roughly one additional module per container on a 26 t limit.

Installation Method – Foundation, Erection and Commissioning

Foundation and Anchor Setting

Cassette Erection and Joint Sealing

Window Installation, Waterproofing and Commissioning

Project Data – Delivered Houses and Measured Results

Two-Module House, 120 m2, Northern China

Two 6.0 x 3.0 m modules with a 200 mm PIR roof cassette, 140 mm rock wool walls and 30 m2 of glazing at Uw 0.724. Site erection took 4 days with a 50 t crane and a five-person crew. Design heat load came in at 22.7 W/m2 and the installed heat pump is 3.5 kW.

Item Value Unit Note
Floor area 120 m2 Two modules
Envelope area 410 m2 7.3% glazed
Design heat load 2,719 W delta T 25 K
Seasonal demand 7,048 kWh/a 58.7 kWh/m2a
Heat pump size 3.5 kW Sized at 22.7 W/m2
Erection time 4 days 5 crew, 50 t crane
Measured n50 0.9 h-1 Blower door EN ISO 9972
Envelope cost FOB 62,400 USD 520 USD/m2

Cost Comparison Against Site-Built

Metric Factory prefab Site-built masonry Delta
Envelope programme 4 days 11 weeks -10.4 weeks
Design heat load 22.7 W/m2 48-62 W/m2 -55%
Heat pump capacity 3.5 kW 8-10 kW -58%
Air tightness n50 0.9 h-1 3.5-5.0 h-1 -78%
Envelope FOB cost 520 USD/m2 330-410 USD/m2 +27-58%
Site labour days 95 380 -75%
Weather delay risk Low High –

The prefab envelope costs 27-58 percent more FOB but removes 285 site labour days and cuts the heating plant by more than half. The crossover depends entirely on local labour rates: above roughly 35 USD per hour the factory route wins on total cost, below 18 USD per hour it does not.

24-Unit Container House Camp

Twenty-four 20 ft container units converted to single-occupancy accommodation, each with a 2400 x 1200 mm window opening framed in RHS 100 x 50 x 3.0 and a 900 x 2100 mm entry door. Header stress came in at 64.2 MPa against 215 MPa allowable. Units were stacked two high, so every cut-out was re-checked for the upper unit load path.

Configuration Comparison – Which Upgrade to Buy First

Three Specification Levels

Parameter Standard Enhanced Passive
Wall core 100 mm PIR 150 mm PIR 200 mm PIR
Wall U 0.212 0.143 0.108
Roof U 0.160 0.120 0.090
Window 24 mm break, double 34 mm foam, double 44 mm foam, triple
Uw 1.521 1.302 0.724
Spacer Aluminium Warm edge Warm edge
Joint psi 0.10 0.05 0.03
n50 1.5 h-1 1.0 h-1 0.6 h-1
Design load 31.5 W/m2 25.4 W/m2 22.7 W/m2
FOB USD/m2 320-480 450-620 620-780

Envelope Against Window – Upgrade Priority

Step Measure UA saved (W/K) Cost (USD) USD per W/K Rank by cost
1 Warm-edge spacer on all glazing 0.6 180 300 5
2 Joint isolator pads 7.0 320 46 1
3 24 to 34 mm thermal break 1.6 1,050 656 6
4 Air tightness 1.5 to 1.0 n50 5.3 480 91 2
5 Double to triple glazing 11.6 2,700 233 3
6 100 to 200 mm wall insulation 14.6 3,900 267 4
7 Argon to krypton fill 1.5 1,080 720 7

Ranked by cost per W/K the joint isolator pads at 46 USD per W/K are the cheapest measure in the whole building, followed by the air tightness work at 91, then triple glazing at 233 and wall insulation at 267. The warm-edge spacer, the 34 mm thermal break and the krypton fill rank 5, 6 and 7. This ordering is only visible if the psi and n50 terms are on the schedule at all – they usually are not.

The window, door and glazed extension packages below are built on the same extrusion and glazing lines as the prefab house envelope, so finishes, hardware and glass build-ups match across the whole project.

Aluminium Window and Door Systems

Glazed Extensions and Roof Systems