Blog

Home   >   Sliding Doors   >   Porte Patio Export from China: Aluminium Porte Coulissante, Baie Vitree Coulissante Sizes, A*E*V* Data & Pricing

Porte Patio Export from China: Aluminium Porte Coulissante, Baie Vitree Coulissante Sizes, A*E*V* Data & Pricing

Aluminium porte patio installed on a French house terrace in China - thermally broken sliding patio door with slim dark grey frames and double glazing
Thermally broken aluminium porte patio, three-panel configuration, installed on a residential terrace in France.
A porte patio is the French term for a glazed sliding door that connects a living space to a terrace or garden. What separates a French specification from a North American one is not the frame material but the paperwork and the dimension grid: the A*E*V* classification under NF EN 12207/12208/12210, the Acotherm acoustic index, the CE marking to NF EN 14351-1, and opening sizes that follow the French modular grid rather than inch dimensions. This article documents frame geometry, glazing build-ups, USD ex-works price bands, test classifications, production sequence, procurement terms, DTU 36.5 installation method and delivered project costs for aluminium porte patio units manufactured in Foshan, Guangdong for shipment to France.
FOB Foshan price
$165-460/m²
Uw value
1.3-2.4 W/m²K
A*E*V* class
A4 E7B VA2
Profile wall
1.8 / 2.0 / 2.2 mm
MOQ
50 m²
Lead time
25-35 days
Contents
1. Porte Coulissante: Three Opening Mechanisms
2. Baie Vitree Coulissante: French Size Grid
3. Porte Coulissante en Aluminium: Profile Data
4. Patio Sliding Door: Tracks and Rollers
5. Porte Patio Price Table (USD)
6. A*E*V*, Uw, Acotherm, CE Data
7. Production and Coating Sequence
8. MOQ, Payment, Shipping to France
9. Installation per DTU 36.5
10. Project Data: Nantes, 34 Houses
11. FAQ

Porte Coulissante: Three Opening Mechanisms Compared

The search term porte coulissante covers three distinct mechanisms. They are not interchangeable: the mechanism determines the achievable air permeability class, the maximum sash weight and the threshold detail, which in turn determines whether the unit can be specified in a French maison individuelle with a step-free access route under the accessibility rules.

Coulissant à frappe classique (standard slide)

The sash rides on two or four rollers along a bottom rail, with brush seals at the head and jambs. Sash weight capacity 80-120 kg. Air permeability reaches A3 on a 2 150 x 2 150 mm two-panel unit; A4 requires additional compression gaskets. This is the configuration used on roughly 70% of French residential orders by panel count.

Coulissant à levage (lift-and-slide)

Turning the handle raises the sash 4-6 mm off the gaskets for travel and drops it onto compression gaskets when closed. Sash weight capacity 200-400 kg, single panels up to 3 000 mm wide and 2 700 mm high. Air permeability A4, water tightness E7B, wind resistance up to VA3 depending on reinforcement. Hardware cost adds $70-140 per sash over standard slide.

Galandage (sliding into wall pocket)

Sashes disappear into a cavity built inside the wall. Net clear opening equals the full frame width. Requires a pocket kit ordered together with the frames, coordination with the masonry contractor, and an insulated cavity closure to avoid a thermal bridge. Cost premium $180-320 per opening; on renovation projects this is often the only way to reach a 1 800 mm clear opening without changing the structural lintel.

Mechanism Max sash weight Air class (A*) Clear opening Hardware premium per sash
Standard slide 80-120 kg A3 (A4 with gasket pack) ~48% of frame width Baseline
Lift-and-slide 200-400 kg A4 ~48% of frame width +$70-140
Galandage (pocket) 120-200 kg A3 ~96% of frame width +$180-320
Tilt-and-slide 100-150 kg A4 ~48% + 100 mm tilt vent +$95-160
Selection rule used in practice: below 2.0 m sash height and 120 kg, standard slide reaches A4 with a compression gasket pack and costs less. Above 2.4 m or 200 kg, lift-and-slide is the only mechanism that keeps the handle torque under 30 N·m for the end user.

Baie Vitree Coulissante: French Size Grid and Panel Layouts

Baie vitrée coulissante is the term used when the opening is wide enough to be treated as a glazed wall rather than a door. French builders order against a modular grid; quoting a millimetre-accurate non-standard size is a common source of rework because the pre-cast lintel and the rough opening are set from the grid.

Standard French rough-opening grid

Cote de passage (clear opening) and cote tableau (masonry opening) values most frequently produced for the French market:

Cote tableau W x H (mm) Panels Cote de passage (mm) Typical room Glass build-up
1 250 x 2 150 2 (1 fixed + 1 slide) 560 Bedroom, kitchen 5+20A+5
1 800 x 2 150 2 840 Living room (small) 5+20A+5
2 150 x 2 150 2 1 020 Living room 5+20A+5
2 400 x 2 150 3 (1 fixed + 2 slide) 1 520 Living room + terrace 6+20A+6
3 000 x 2 150 3 1 920 Open-plan living 6+20A+6
3 600 x 2 400 4 (2 fixed + 2 centre) 2 300 Villa, pool house 6+20A+6 laminated
4 200 x 2 400 4 2 700 Hotel lobby, showroom 8+20A+8 laminated

Threshold options and step height

French accessibility rules for new individual houses require a threshold rebate of 4 mm or less where a step-free route is claimed. Two threshold types are produced:

Frame depth at the threshold is 20 mm lower than the head section; on 2 400 mm openings the bottom rail is drained through two 6 x 25 mm slots per panel into the external cavity.

Porte Coulissante en Aluminium: Profile, Thermal Break and Coating

The search term porte coulissante en aluminium maps to three profile generations. The generation is defined by polyamide strip width and frame depth, and it is the single biggest driver of the Uw number that appears in the RE2020 calculation.

Alloy, temper and wall thickness

Profiles are extruded from 6063-T5 (Si 0.20-0.60%, Mg 0.45-0.90%), minimum tensile strength 160 MPa, yield 110 MPa, elongation 8%. Wall thickness is measured on the load-bearing webs of the outer and inner half-shells:

Wall thickness Application Max sash height Deflection at 1 000 Pa Wind class
1.8 mm Standard residential, 2 rails 2 400 mm L/180 VA2
2.0 mm Coastal, upper floors 3-6 2 700 mm L/200 VA2-VA3
2.2 mm Ground-floor 3 000 mm, exposed sites 3 000 mm L/250 VA3
2.5 mm (reinforced) VB class, cyclone zones 3 300 mm L/300 VB1

Thermal break geometry

The polyamide strip is PA66 GF25 (25% glass fibre), measured across the break:

Coating specifications

Two finishes are shipped to France. Polyester powder coat at 60-80 μm dry film thickness to Qualicoat Class 1 (Seaside Class 2 available for coastal sites within 3 km of the sea) is the default. Anodising to 15 μm AA15 or 20 μm AA20 per Qualanod is specified on roughly 8% of French orders, mostly in natural silver and bronze. Colour reference is RAL or the French AFNOR Nuancier; dual-colour (grey 7016 external / white 9016 internal) adds $12-18 per m² and is requested on about 45% of orders.

Patio Sliding Door: Track Systems, Rollers and Sash Weight

On the English-language term patio sliding door the specification conversation is dominated by hardware endurance. NF EN 13126-15 requires the roller assembly to complete 10 000 open/close cycles at class H3 (heavy domestic) and 25 000 cycles at class H4 (heavy commercial) without loss of function.

Roller specification

Roller type Wheel Bearing Load rating Cycle rating
Single wheel, steel Ø 28 mm, POM tyre Plain bushing 60 kg 5 000 cycles (H2)
Twin wheel, steel Ø 32 mm, POM tyre Sealed ball 6001ZZ 120 kg 10 000 cycles (H3)
Twin wheel, stainless Ø 38 mm, PU tyre Sealed ball 6201ZZ 200 kg 25 000 cycles (H4)
Lift-slide carriage Ø 42 mm, PU tyre Sealed ball 6202ZZ 400 kg 25 000 cycles (H4)

Track material and wear

Stainless steel 304 track caps are fitted over the aluminium rail on units above 150 kg sash weight. Without the cap, the POM wheel running directly on mill-finish aluminium shows measurable rail wear after roughly 8 000 cycles in salt-spray-exposed sites. The cap adds $9-14 per metre of track and is included on all lift-and-slide units by default.

Handle and locking

A cremone hook lock with 2-4 locking points is standard. On units ordered for French ground-floor installations, a 6-point hook lock plus a keyed cylinder on both faces is the configuration that satisfies insurer requirements under the A2P BP1 grading referenced in most French multi-risk home policies.

Porte Patio Price Table: FOB Foshan / Shenzhen, USD per m²

Prices below are ex-works Foshan, quoted per square metre of finished opening area, for container-load quantities (300 m² and above) on a 2026-Q3 aluminium ingot assumption of USD 2 450/tonne on the Shanghai Futures Exchange. Prices move with ingot: the adjustment clause is ±0.6% per 100 USD/tonne change.

Configuration Profile wall Thermal break Glazing USD / m² FOB
2-panel standard slide 1.8 mm 20 mm PA66 GF25 5+20A+5 float $165 – 205
2-panel, Low-E + argon 1.8 mm 20 mm 5+20Ar+5 Low-E $196 – 238
3-panel standard slide 2.0 mm 20 mm 6+20Ar+6 Low-E $225 – 272
3-panel lift-and-slide 2.0 mm 24 mm + foam 6+20Ar+6 Low-E $298 – 352
4-panel lift-and-slide 2.2 mm 24 mm + foam 6+20Ar+6 laminated $338 – 398
Galandage pocket kit 2.0 mm 20 mm 6+20Ar+6 Low-E $352 – 412
Cyclone-rated VB1 (coastal) 2.5 mm reinforced 24 mm + foam 8+20Ar+8 laminated $398 – 460

Where the money goes

On a 3 000 x 2 150 mm three-panel lift-and-slide unit at $320/m², the bill of materials breaks down as: aluminium profile 38%, glass 21%, hardware 19%, coating 6%, gaskets and consumables 5%, labour and overhead 11%. Glass and hardware together account for 40%, which is why a spec change from 6+20Ar+6 to 8+20Ar+8 laminated moves the price by $46-58/m² rather than proportionally to the panel size.

Price bands exclude French import VAT (20%), customs duty on aluminium doors (0% under the applicable tariff heading for most Chinese-origin aluminium joinery when a valid origin declaration is presented), and inland delivery. Budget $38-62 per m² for a 40-foot container share from Foshan to Le Havre including port handling, and $14-24 per m² for last-mile delivery to a site within 300 km of the port.

Test Data: A*E*V*, Uw, Acotherm and CE EN 14351-1

France uses the A*E*V* classification set rather than the North American performance grade system. The three letters come from NF EN 12207 (air), NF EN 12208 (water) and NF EN 12210 (wind), with the updated V* notation for wind resistance and deflection.

Measured results, 2 150 x 2 150 mm two-panel lift-and-slide

Property Standard Test pressure Result Class
Air permeability NF EN 1026 / 12207 600 Pa 0.35 m³/h·m² A4
Water tightness NF EN 1027 / 12208 450 Pa No leakage E7B
Wind resistance NF EN 12211 / 12210 1 800 Pa No damage VA2
Wind deflection NF EN 12211 1 200 Pa L/220 VB2 (deflection)
Thermal transmittance Uw NF EN ISO 10077-1 1.4 W/m²K
Acoustic Rw (C;Ctr) NF EN ISO 717-1 36 (-1;-4) dB AC2 Acotherm
Solar factor Sw NF EN 410 0.42
Operating force NF EN 13115 78 N Class 2

Acoustic upgrade path

Acoustic class is the most frequently missed requirement on French projects. Rw 36 dB (AC2) is reached with an asymmetric build-up of 6+12A+44.2 acoustic laminated. Moving to AC3 (Rw 39 dB) requires 8+12A+44.2, and AC4 (Rw 42 dB) needs 44.2+16A+66.2 with a heavier 2.2 mm wall. Each step adds 18-24 kg per m² of sash, which pushes the hardware selection up one class.

CE marking and documentation

Doorsets are CE marked under NF EN 14351-1, AVCP system 3, with an ITT (initial type test) report from a notified laboratory. The Declaration of Performance lists the eight essential characteristics. A French buyer will normally ask for the DOP, the ITT summary, and a DoP reference number that can be checked against the manufacturer. ACOTHERM certificates are issued per glazing configuration, not per frame, so the acoustic certificate must be matched to the exact glass build-up ordered.

Production and Coating Sequence

A container of porte patio units goes through nine stations. Knowing the sequence helps when a project needs a partial shipment or a colour match across two orders.

Extrusion and ageing

Billet 6063 is heated to 480-520 °C and extruded at 12-18 m/min through a die, then quenched by air or water and artificially aged at 195-205 °C for 4 hours to reach T5. Length tolerance ±0.5 mm on cut-to-length, ±0.15 mm on wall thickness.

Thermal break assembly

The PA66 GF25 strip is knurled and rolled into the profile knurls under 3 500-4 500 N per metre, then the assembly is mechanically crimped. Shear test per EN 14024 requires a minimum of 24 N/mm across the break; production sampling is one test per 300 bars.

Surface treatment line

Nine-stage pre-treatment: degrease at 55-65 °C, alkaline etch, two rinses, chrome-free conversion coating (Ti/Zr based), two deionised rinses, dry-off at 110 °C. Powder is applied electrostatically at 60-80 kV in a closed loop with overspray recovery, cured at 195-205 °C for 12-15 minutes at metal temperature. Film thickness is checked at six points per bar; the Qualicoat Class 1 window is 60-120 μm.

Glazing and assembly

Insulated glass units are produced on a butyl-primary / polysulfide-secondary line with 90% argon fill for Low-E configurations. Warm-edge spacer (stainless or composite) is used on Uw targets at or below 1.5 W/m²K. Sash assembly torque: 4.5 N·m on corner cleat crimps, 8 N·m on hardware fixing screws into 2.0 mm walls.

Packing

Units are wrapped in 0.08 mm PE film, corners protected with 3 mm EPE profile, then stacked vertically in a steel A-frame with 20 mm rubber separation. A 40-foot high-cube container holds 320-380 m² of assembled frames on A-frames, or 480-560 m² knocked-down. Glass is shipped in the same container in a separate A-frame unless pre-glazed is specified, which reduces the load to 260-300 m².

MOQ, Payment Terms, Lead Time and Shipping to France

Commercial terms

Item Standard term Notes
MOQ 50 m² per order Mixed sizes allowed; single-size runs below 30 m² carry a $180 setup fee
Sample opening 1 unit, 1 250 x 2 150 mm $260-390 including crating, deductible from first order
Payment 30% deposit, 70% before loading Irrevocable L/C at sight accepted from 20 ft and above
Currency USD or EUR EUR quotes held for 14 days
Price validity 30 days Ingot clause ±0.6% per 100 USD/tonne
Production lead time 25-35 days From approved shop drawing and deposit
Anodised finish +7 days AA15 standard, AA20 on request
Port of loading Foshan / Shenzhen Yantian Truck 2 hours to terminal

Shipping to France

Foshan to Le Havre is 26-32 days on a direct service, 34-40 days with transhipment via Singapore. Fos-sur-Mer and Dunkirk are 3-5 days longer. Freight on a 40 ft high cube to Le Havre has ranged USD 2 100-3 400 in 2026; on a 300 m² shipment that is $7-11 per m². Customs clearance requires the commercial invoice, packing list, bill of lading, EUR.1 or a statement on origin for preferential treatment where applicable, and the CE/DoP documentation package.

What to send with the enquiry

Installation per DTU 36.5: Sequence, Waterproofing and Adjustment

French installation practice follows DTU 36.5 (menuiseries extérieures en aluminium) together with the DTU 20.1 masonry tolerances. Installing a thermally broken unit with a thermal-bridge-free perimeter is what determines whether the lab Uw is achieved on site.

Sequence

Adjustment after glazing

Roller height is adjusted through the access holes in the sash stile with a 4 mm hex key: raise or lower until the sash sits parallel to the frame with a 3-4 mm uniform gap at the head. Locking point compression is set by rotating the mushroom cams; the target is 1.5-2 mm preload measured with a feeler gauge. Final operating force should fall under 100 N for a 150 kg sash.

Three failure modes seen on site

Project Data: 34-House Lotissement near Nantes

A 34-unit residential development in the Nantes metropolitan area, delivered across two phases, illustrates how the specification choices above translate into a delivered cost.

Scope and configuration

Item Value
Total glazed area 612 m² (18 m² average per house)
Openings per house 1 x 3 000 x 2 150 three-panel, 1 x 1 250 x 2 150 two-panel
Configuration Lift-and-slide on the 3 000 mm, standard slide on the 1 250 mm
Profile 2.0 mm wall, 24 mm PA66 GF25 + foam insert
Glazing 6+20Ar+6 Low-E (Ug 1.1), warm-edge spacer
Coating RAL 7016 external / RAL 9016 internal, Qualicoat Class 1
Threshold Seuil PMR, 4 mm upstand
Certification CE NF EN 14351-1, A4 E7B VA2, Acotherm AC2

Delivered cost comparison

The developer evaluated three sources before ordering:

Source FOB / ex-works $/m² Freight + duty $/m² Delivered $/m² Lead time Uw achieved
French domestic fabricator $612 $18 $630 9 weeks 1.4 W/m²K
EU (Poland) fabricator $458 $31 $489 6 weeks 1.6 W/m²K
Foshan factory (this scope) $318 $49 $367 5 weeks + 30 days sea 1.4 W/m²K

On 612 m² the delivered saving against the French domestic quote was $161 000, or 41.7%. The project absorbed 30 days of sea transit plus 4 days of customs clearance, which the programme absorbed by ordering at the rough opening stage rather than after the roof was closed. Installation defects recorded at handover were 11 items across 34 houses, all perimeter sealing at the head; none involved the frames.

The 41.7% delivered saving is specific to this scope, quantity and shipping rate. On a single-house order of 18 m² the freight and clearance overhead rises to $95-130 per m² and the saving narrows to roughly 18-24%.

FAQ

What is the difference between a porte patio and a baie vitrée?

In everyday French usage both terms describe glazed sliding doors. Baie vitrée is used when the opening is wide enough to read as a glazed wall, typically 2 400 mm and above or with three or more panels. The frame and hardware families are the same.

Can a Chinese-manufactured unit be CE marked for France?

Yes. CE marking under NF EN 14351-1 is a manufacturer declaration backed by an initial type test from a notified laboratory, AVCP system 3. The DoP and the ITT report are what a French control office checks. See the aluminium windows and doors specification data for the declaration structure.

Which Uw is needed for MaPrimeRénov eligibility?

The window replacement grant requires Uw at or below 1.3 W/m²K and Sw at or above 0.36 for the eligible window and door scope. A 24 mm thermal break with 6+20Ar+6 Low-E reaches Uw 1.3 on a two-panel unit; a three-panel unit needs the 34 mm multi-chamber profile to reach the same figure.

What is the minimum order and can sizes be mixed?

50 m² per order, and sizes can be mixed freely. Runs below 30 m² of a single size carry a $180 die and setup charge.

Is lift-and-slide worth it for a 1 800 mm opening?

Usually not. Below 2.0 m and 120 kg sash weight, a standard slide with a compression gasket pack reaches A4 for $70-140 per sash less. The step change where lift-and-slide becomes necessary is sash height above 2 400 mm or weight above 200 kg.

Related reading: sliding patio door specifications and Spanish CTE requirements, aluminium sliding glass door wholesale data, patio doors from the Foshan Guangdong factory, heavy-duty sliding systems for villas, fenêtre coulissante frame and A*E*V* data, aluminium glass door configurations, how to choose sliding doors, and Foshan window and door brands compared.
[footer_contact_form]